Relationship between pain and tissue damage due to thermal radiation
The DOI matches its Crossref record.
Abstract
Sites on the volar surfaces of the forearms of human subjects were blackened with India ink and exposed to thermal irradiances of from 50 to 400 mcal/cm 2 sec. The exposure time and skin temperature at which threshold pain occurred, and which produced minimal blistering within 24 hours, were noted. The thermal inertia (k⍴c) of the skin was shown to vary directly with the level of irradiance. The receptors effective in mediating the pain sensation were calculated to be at a depth of approximately 200 μ and to have a threshold of approximately 43.2℃. Tissue damage rates with respect to temperature were derived empirically so that damage integrated over the time for which skin temperature was elevated over the pain threshold was equated to unity. The substitution of the ratio of these rates with respect to temperature for the stimulus ratio, in the prediction of the observed discriminable steps in pain sensation intensity, yielded faithful reproduction of the just noticeable differences observed for pain through the range of this sensation. Submitted on September 17, 1958
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rácz, I., & Zimmer, A. (2006) · Standards of Mouse Model Phenotyping · doi:10.1002/9783527611942.ch9 · Cited by 1,659
Le Bars, D., Gozariu, M., & Cadden, S. W. (2001) · Pharmacological Reviews · doi:10.1016/s0031-6997(24)01514-x · Cited by 1,459
Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia
Dewhirst, M. W., Viglianti, B. L., Lora-Michiels, M., Hanson, M., & Hoopes, P. J. (2003) · International Journal of Hyperthermia · doi:10.1080/0265673031000119006 · Cited by 1,014
Electronic Muscles and Skins: A Review of Soft Sensors and Actuators
Chen, D., & Pei, Q. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00019 · Cited by 506
Non-Fourier analysis of skin biothermomechanics
Xu, F., Seffen, K. A., & Lu, T. J. (2008) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2007.10.024 · Cited by 373
Mathematical Modeling of Skin Bioheat Transfer
Xu, F., Lu, T. J., Seffen, K. A., & Ng, E. Y. K. (2009) · Applied Mechanics Reviews · doi:10.1115/1.3124646 · Cited by 242
Duck, F. A. (1990) · Physical Properties of Tissues · doi:10.1016/b978-0-12-222800-1.50006-1 · Cited by 223
MEASUREMENT OF THE THERMAL PROPERTIES OF HUMAN SKIN. A REVIEW
Cohen, M. L. (1977) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12507965 · Cited by 179
Modeling of Bioheat Transfer Processes at High and Low Temperatures
Diller, K. R. (1992) · Advances in Heat Transfer · doi:10.1016/s0065-2717(08)70345-9 · Cited by 175
Firefighter Safety Zones: A Theoretical Model Based on Radiative Heating
Butler, B., & Cohen, J. (1998) · International Journal of Wildland Fire · doi:10.1071/wf9980073 · Cited by 165
“Others suggest that the upper limit of incident radiant heat flux on bare skin that can be sustained without injury for a short time (less than 2 minutes) is approximately 2.3 kW-m (Stoll and Greene 1959; Budd and Cheney 1984; Fogarty 1996).”
BackgroundInfluentialA review of the evidence for threshold of burn injury
Martin, N. A., & Falder, S. (2017) · Burns · doi:10.1016/j.burns.2017.04.003 · Cited by 160
Clothing for protection against heat and flames
Rossi, R. (2014) · Protective Clothing · doi:10.1533/9781782420408.1.70 · Cited by 17
Continuous cooling system in conjunction with laser surgery for ear reshaping.
Hsiao, Y.-C., Ting, K., Su, Y.-L., & Chang, C.-J. (2020) · Lasers in Medical Science · doi:10.1007/s10103-019-02831-3 · Cited by 3
Metadata
- Authors
- Stoll, A. M., & Greene, L. C.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1959-05-01
- Volume
- 14
- Issue
- 3
- Pages
- 373-382
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2290094084
- Cited by
- 327
- References
- 0
- FWCI
- 2.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.