Light-absorbing properties, stability, and spectral stabilization of indocyanine green
Abstract
The absorption spectrum of indocyanine green depends on the nature of the solvent medium and on the dye concentration. Binding to plasma proteins causes the principal peaks in the absorption spectrum to shift about 25 nm toward the higher wavelengths. The much greater influence on the spectrum of the dye concentration results from progressive aggregate formation with increasing concentration. Indocyanine green solutions therefore do not follow Lambert-Beer's law above 15 mg-I-1 (in plasma). Indocyanine green solutions in plasma and concentrated (1,000 mg-I-1) solutions in distilled water are stable for at least 4 h. In long-term experiments the optical density of indocyanine green solutions in plasma as well as in distilled water generally diminishes, even in the dark. On the 7th day a new absorption maximum starts to appear at gamma=900 nm, possibly caused by further aggregate formation leading to much larger particles. Spectral stabilization after injection of a concentrated solution into the blood is most rapid when the dye is dissolved in distilled water. Spectral stabilization slows down with decreasing temperature. As rapid spectral stabilization is essential in quantitative dye dilution studies, the practice of adding a albumin and/or isotonic saline solution to the injectate should be discontinued. When a 10 g-1(-1) aqueous solution of indocyanine green is used, spectral stabilization takes less than 1.5 a (at 37 degrees C), which is sufficiently fast for almost any application.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Real‐time identification of liver cancers by using indocyanine green fluorescent imaging
Ishizawa, T., Fukushima, N., Shibahara, J., Masuda, K., Tamura, S., Aoki, T., Hasegawa, K., Beck, Y., Fukayama, M., & Kokudo, N. (2009) · Cancer · doi:10.1002/cncr.24291 · Cited by 852
Carr, J. A., Franke, D., Caram, J. R., Perkinson, C. F., Saif, M., Askoxylakis, V., Datta, M., Fukumura, D., Jain, R. K., Bawendi, M. G., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1718917115 · Cited by 721
Volumetric real-time multispectral optoacoustic tomography of biomarkers
Razansky, D., Buehler, A., & Ntziachristos, V. (2011) · Nature Protocols · doi:10.1038/nprot.2011.351 · Cited by 309
Indocyanine Green: Physicochemical Factors Affecting Its Fluorescencein Vivo
Mordon, S., Devoisselle, J. M., Soulie-Begu, S., & Desmettre, T. (1998) · Microvascular Research · doi:10.1006/mvre.1998.2068 · Cited by 268
A general approach to the design of high-performance near-infrared (NIR) D-π-A type fluorescent dyes
Luo, X., Li, J., Zhao, J., Gu, L., Qian, X., & Yang, Y. (2019) · Chinese Chemical Letters · doi:10.1016/j.cclet.2019.03.012 · Cited by 119
Metadata
- Authors
- Landsman, M. L., Kwant, G., Mook, G. A., & Zijlstra, W. G.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1976-04-01
- Volume
- 40
- Issue
- 4
- Pages
- 575-583
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2106270682
- Cited by
- 834
- References
- 0
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Light-absorbing properties, stability, and spectral stabilization of indocyanine green. https://app.cochat.ai/papers/10.1152/jappl.1976.40.4.575
- The paper
- Landsman, M. L., Kwant, G., Mook, G. A., & Zijlstra, W. G. (1976). Light-absorbing properties, stability, and spectral stabilization of indocyanine green. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1976.40.4.575
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.