Calculated deposition of inhaled particles in the airway generations of normal subjects
The DOI matches its Crossref record.
Abstract
Detailed regional deposition of inhaled particles in the human lung is calculated for individual airway generations. The calculations are based on Landahl's deposition model as applied to the morphometric lung model of Weibel. We consider primarily deposition patterns of iron oxide particles with diameters ranging between 1 and 10 micrometers, but we also calculate patterns of deposition for bis(2-ethylhexyl) sebacate particles with diameters as small as 0.2 micrometers. We obtain good agreement between predicted values and observed values for alveolar retention of inhaled iron oxide particles with 64 and 20% of total deposition predicted to occur in nonciliated airways for 2- and 5-micrometer particles, respectively. This is compared with 48 +/- 9 and 27 +/- 10% for the measured values. Calculated values for total lung deposition of small bis(2-ethylhexyl) sebacate particles agree well with experimental data. The calculations show a minimum in deposition occurring for particle diameters of 0.5 micrometers, which is in agreement with observations. A calculation of surface concentration of deposited 7.9-micrometer aerodynamic particles reveals a very large concentration occurring at airway generation four. This observation is considered in light of observations that bronchial carcinomas occur in this vicinity of the lung.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Regional Lung Deposition and Bronchodilator Response as a Function of β 2 -Agonist Particle Size
Usmani, O. S., Biddiscombe, M. F., & Barnes, P. J. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200410-1414oc · Cited by 578
Modelling inhaled particle deposition in the human lung—A review
Hofmann, W. (2011) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2011.05.007 · Cited by 492
Recent advances in pulmonary drug delivery using large, porous inhaled particles
Edwards, D. A., Ben-Jebria, A., & Langer, R. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.85.2.379 · Cited by 341
Technological and practical challenges of dry powder inhalers and formulations
Hoppentocht, M., Hagedoorn, P., Frijlink, H. W., & de Boer, A. H. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.04.004 · Cited by 303
Localization of Secretory Mucins MUC5AC and MUC5B in Normal/Healthy Human Airways
Okuda, K., Chen, G., Subramani, D. B., Wolf, M., Gilmore, R. C., Kato, T., Radicioni, G., Kesimer, M., Chua, M., Dang, H., et al. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201804-0734oc · Cited by 293
Dry powder inhalation: past, present and future
de Boer, A. H., Hagedoorn, P., Hoppentocht, M., Buttini, F., Grasmeijer, F., & Frijlink, H. W. (2017) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2016.1224846 · Cited by 271
Aerosol deposition considerations in inhalation therapy
Newman, S. P. (1985) · Chest · doi:10.1378/chest.88.2.152s · Cited by 264
Airborne infectious disease and the suppression of pulmonary bioaerosols
Fiegel, J., Clarke, R., & Edwards, D. A. (2006) · Drug Discovery Today · doi:10.1016/s1359-6446(05)03687-1 · Cited by 184
“Expired bioaerosols can also travel great distances and remain airborne for an extended period of time, particularly when droplet diameters are too large for diffusive deposition (>200 nm) or too small for gravitational deposition (<2 µm) [15, 16] .”
Mathematical analysis of particle deposition in human lungs: An improved single path transport model
Choi, J.-I., & Kim, C. S. (2007) · Inhalation Toxicology · doi:10.1080/08958370701513014 · Cited by 101
“…as a serial structure consisting of a number of discrete airway 925 generations and deposition is calculated for each generation in a fashion of sequential filtration (i.e., filtration model) (Landahl, 1950; Beeckmans, 1965; Gerrity et al., 1979; Yeh & Shum, 1980; Kim et al., 1983; Martonen, 1993).”
Method
Metadata
- Authors
- Gerrity, T. R., Lee, P. S., Hass, F. J., Marinelli, A., Werner, P., & Lourenco, R. V.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1979-10-01
- Volume
- 47
- Issue
- 4
- Pages
- 867-873
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2175111931
- Cited by
- 180
- References
- 0
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.