Acute hypervolemia, cardiac performance, and aerobic power during exercise
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The relative importance of blood volume (BV) for the maximum aerobic power (VO2 max) was evaluated in healthy subjects by sequential measurements without intervention under two conditions: 1) after hemodilution with a plasma expander, thus increasing BV but keeping red cell mass constant and lowering hemoglobin concentration [Hb], and 2) after whole blood withdrawal, which restored BV to control conditions but reduced red cell mass and [Hb] to equal conditions under 1. After BV expansion (avg 700 ml), we found an unchanged VO2 max compared with control data despite lowered [Hb]. Cardiac output (Q) was increased after BV expansion at rest and during all exercise levels (maximum 27.4 and 29.5 l . min-1, respectively). Peak stroke volume was increased from 144 to 173 ml. Arterial blood pressures were either unchanged or lowered. In contrast, after blood letting to a similar [Hb], we found a significantly reduced VO2 max. These findings indicate a significant influence of the size of the blood volume on cardiac performance. The increased Qmax is discussed in relation to preload, inotropic state, heart rate, and afterload. Plasma volume expansion causes increased preload which may explain this primary effect on the central circulation (Frank-Starling effect).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cardiac output during submaximal and maximal work
Åstrand, P.-O., Cuddy, T. E., Saltin, B., & Stenberg, J. (1964) · Journal of Applied Physiology · doi:10.1152/jappl.1964.19.2.268 · Cited by 722
Response to exercise after blood loss and reinfusion
Ekblom, B., Goldbarg, A. N., & Gullbring, B. (1972) · Journal of Applied Physiology · doi:10.1152/jappl.1972.33.2.175 · Cited by 346
Self-citation
Cited by
Cardiovascular Adaptations to Physical Training
Blomqvist, C. G., & Saltin, B. (1983) · Annual Review of Physiology · doi:10.1146/annurev.ph.45.030183.001125 · Cited by 709
Biology of VO2max: looking under the physiology lamp
Lundby, C., Montero, D., & Joyner, M. (2017) · Acta Physiologica · doi:10.1111/apha.12827 · Cited by 300
Integration of Cardiovascular Control Systems in Dynamic Exercise
Rowell, L. B., O'Leary, D. S., & Kellogg, D. L. (1996) · Comprehensive Physiology · doi:10.1002/cphy.cp120117 · Cited by 217
Neufer, P. D. (1989) · Sports Medicine · doi:10.2165/00007256-198908050-00004 · Cited by 203
“Live high–train low” using normobaric hypoxia: a double-blinded, placebo-controlled study
Siebenmann, C., Robach, P., Jacobs, R. A., Rasmussen, P., Nordsborg, N., Diaz, V., Christ, A., Olsen, N. V., Maggiorini, M., & Lundby, C. (2012) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00388.2011 · Cited by 156
Metadata
- Authors
- Kanstrup, I. L., & Ekblom, B.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1982-05-01
- Volume
- 52
- Issue
- 5
- Pages
- 1186-1191
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1915125682
- Cited by
- 123
- References
- 2
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Acute hypervolemia, cardiac performance, and aerobic power during exercise. https://app.cochat.ai/papers/10.1152/jappl.1982.52.5.1186
- The paper
- Kanstrup, I. L., & Ekblom, B. (1982). Acute hypervolemia, cardiac performance, and aerobic power during exercise. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1982.52.5.1186
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.