CoChat

Acute hypervolemia, cardiac performance, and aerobic power during exercise

Kanstrup, I. L., Ekblom, B. · 1982 · Journal of Applied Physiology
Cited by 123

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The relative importance of blood volume (BV) for the maximum aerobic power (VO2 max) was evaluated in healthy subjects by sequential measurements without intervention under two conditions: 1) after hemodilution with a plasma expander, thus increasing BV but keeping red cell mass constant and lowering hemoglobin concentration [Hb], and 2) after whole blood withdrawal, which restored BV to control conditions but reduced red cell mass and [Hb] to equal conditions under 1. After BV expansion (avg 700 ml), we found an unchanged VO2 max compared with control data despite lowered [Hb]. Cardiac output (Q) was increased after BV expansion at rest and during all exercise levels (maximum 27.4 and 29.5 l . min-1, respectively). Peak stroke volume was increased from 144 to 173 ml. Arterial blood pressures were either unchanged or lowered. In contrast, after blood letting to a similar [Hb], we found a significantly reduced VO2 max. These findings indicate a significant influence of the size of the blood volume on cardiac performance. The increased Qmax is discussed in relation to preload, inotropic state, heart rate, and afterload. Plasma volume expansion causes increased preload which may explain this primary effect on the central circulation (Frank-Starling effect).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1982.52.5.1186

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 123

Metadata

Authors
Kanstrup, I. L., & Ekblom, B.
Venue
Journal of Applied Physiology
Published
1982-05-01
Volume
52
Issue
5
Pages
1186-1191
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1915125682
Cited by
123
References
2
FWCI
2.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Acute hypervolemia, cardiac performance, and aerobic power during exercise. https://app.cochat.ai/papers/10.1152/jappl.1982.52.5.1186
The paper
Kanstrup, I. L., & Ekblom, B. (1982). Acute hypervolemia, cardiac performance, and aerobic power during exercise. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1982.52.5.1186

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.