Supraglottic airway resistance in normal subjects and patients with occlusive sleep apnea
The DOI matches its Crossref record.
Abstract
We assessed the flow-impeding properties of nose and pharynx combined in four normals and five patients with occlusive sleep apnea (OSA) while awake by measuring supraglottic pressure and airflow at the nose. We calculated two indices of impedance presented by the supraglottic airway: the second coefficient (K2) of Rohrer's equation and supraglottic resistance (Rsg) at 0.4 l/s. The influence of posture and nasal mucosal circulation was evaluated by measuring these indices in sitting and supine position before and after administration of a nasal decongestant. The effects of changes in posture were similar in both normals and patients: K2 and Rsg values were significantly larger in supine than in sitting position. The nasal decongestant significantly decreased both values in sitting and supine positions for normals and patients but did not eliminate the posturally induced changes. Patients had significantly greater K2 and Rsg values than normals in all conditions. These results indicate supraglottic airway narrowing in OSA patients. This narrowing probably results from structural encroachment on the pharyngeal airway.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The diagnosis and management of rhinitis: An updated practice parameter
WALLACE, D., DYKEWICZ, M., BERNSTEIN, D., BLESSINGMOORE, J., COX, L., KHAN, D., LANG, D., NICKLAS, R., OPPENHEIMER, J., & PORTNOY, J. (2008) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2008.06.003 · Cited by 1,096
“Other indications for rhinomanometry include the evaluation of patients with obstructive sleep apnea.(217)”
BackgroundMethodMezzanotte, W. S., Tangel, D. J., & White, D. P. (1992) · Journal of Clinical Investigation · doi:10.1172/jci115751 · Cited by 769
Dykewicz, M. S., Fineman, S., Skoner, D. P., Nicklas, R., Lee, R., Blessing-Moore, J., Li, J. T., Bernstein, I. L., Berger, W., Spector, S., et al. (1998) · Annals of Allergy, Asthma & Immunology · doi:10.1016/s1081-1206(10)63155-9 · Cited by 652
Oral Appliances for the Treatment of Snoring and Obstructive Sleep Apnea: A Review
Schmidt-Nowara, W., Lowe, A., Wiegand, L., Cartwright, R., Perez-Guerra, F., & Menn, S. (1995) · Sleep · doi:10.1093/sleep/18.6.501 · Cited by 543
Anatomy of pharynx in patients with obstructive sleep apnea and in normal subjects
Isono, S., Remmers, J. E., Tanaka, A., Sho, Y., Sato, J., & Nishino, T. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.4.1319 · Cited by 534
Self-citationEffects of Obesity on Respiratory Resistance
Zerah, F., Harf, A., Perlemuter, L., Lorino, H., Lorino, A.-M., & Atlan, G. (1993) · Chest · doi:10.1378/chest.103.5.1470 · Cited by 450
Pelosi, P., Croci, M., Ravagnan, I., Vicardi, P., & Gattinoni, L. (1996) · Chest · doi:10.1378/chest.109.1.144 · Cited by 399
The upper airway in sleep: physiology of the pharynx
Ayappa, I., & Rapoport, D. M. (2003) · Sleep Medicine Reviews · doi:10.1053/smrv.2002.0238 · Cited by 340
Pathophysiology of obstructive sleep apnoea
Deegan, P., & McNicholas, W. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08071161 · Cited by 330
“Nasal resistance is elevated in OSA patients [60–62], and the use of nasal decongestants can reduce supraglottic resistance in OSA [61].”
BackgroundResultInfluentialMorphology of the Uvula in Obstructive Sleep Apnea
Stauffer, J. L., Buick, M. K., Bixler, E. O., Sharkey, F. E., Abt, A. B., Manders, E. K., Kales, A., Cadieux, R. J., Barry, J. D., & Zwillich, C. W. (1989) · American Review of Respiratory Disease · doi:10.1164/ajrccm/140.3.724 · Cited by 185
A cephalometric comparison of subjects with snoring and obstructive sleep apnoea
Battagel, J. (2000) · The European Journal of Orthodontics · doi:10.1093/ejo/22.4.353 · Cited by 172
Sériès, F., Côté, C., Simoneau, J. A., Gélinas, Y., St Pierre, S., Leclerc, J., Ferland, R., & Marc, I. (1995) · Journal of Clinical Investigation · doi:10.1172/jci117640 · Cited by 169
The cephalometric morphology of patients with obstructive sleep apnoea (OSA)
Battagel, J. M., & L'Estrange, P. R. (1996) · The European Journal of Orthodontics · doi:10.1093/ejo/18.1.557 · Cited by 164
Sleep apnea and hypothyroidism: mechanisms and management
Grunstein, R. R., & Sullivan, C. E. (1988) · The American Journal of Medicine · doi:10.1016/s0002-9343(88)80020-2 · Cited by 179
Sleep apnea and body position during sleep
George, C. F., Millar, T. W., & Kryger, M. H. (1988) · Sleep · doi:10.1093/sleep/11.1.90 · Cited by 136
Elevated Posture for the Management of Obstructive Sleep Apnea
Skinner, M. A., Kingshott, R. N., Jones, D. R., Homan, S. D. R., & Taylor, D. R. (2004) · Sleep and Breathing · doi:10.1055/s-2004-860896 · Cited by 63
Verin, E., Tardif, C., Buffet, X., Marie, J. P., Lacoume, Y., Andrieu-Guitrancourt, J., & Pasquis, P. (2002) · Respiration Physiology · doi:10.1016/s0034-5687(01)00324-3 · Cited by 48
Metadata
- Authors
- Anch, A. M., Remmers, J. E., & Bunce, H.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1982-11-01
- Volume
- 53
- Issue
- 5
- Pages
- 1158-1163
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2181492687
- Cited by
- 173
- References
- 0
- FWCI
- 6.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.