The DOI matches its Crossref record.
Diffusion limitation in normal humans during exercise at sea level and simulated altitude
Abstract
The relative roles of ventilation-perfusion (VA/Q) inequality, alveolar-capillary diffusion resistance, postpulmonary shunt, and gas phase diffusion limitation in determining arterial PO2 (PaO2) were assessed in nine normal unacclimatized men at rest and during bicycle exercise at sea level and three simulated altitudes (5,000, 10,000, and 15,000 ft; barometric pressures = 632, 523, and 429 Torr). We measured mixed expired and arterial inert and respiratory gases, minute ventilation, and cardiac output. Using the multiple inert gas elimination technique, PaO2 and the arterial O2 concentration expected from VA/Q inequality alone were compared with actual values, lower measured PaO2 indicating alveolar-capillary diffusion disequilibrium for O2. At sea level, alveolar-arterial PO2 differences were approximately 10 Torr at rest, increasing to approximately 20 Torr at a metabolic consumption of O2 (VO2) of 3 l/min. There was no evidence for diffusion disequilibrium, similar results being obtained at 5,000 ft. At 10 and 15,000 ft, resting alveolar-arterial PO2 difference was less than at sea level with no diffusion disequilibrium. During exercise, alveolar-arterial PO2 difference increased considerably more than expected from VA/Q mismatch alone. For example, at VO2 of 2.5 l/min at 10,000 ft, total alveolar-arterial PO2 difference was 30 Torr and that due to VA/Q mismatch alone was 15 Torr. At 15,000 ft and VO2 of 1.5 l/min, these values were 25 and 10 Torr, respectively. Expected and actual PaO2 agreed during 100% O2 breathing at 15,000 ft, excluding postpulmonary shunt as a cause of the larger alveolar-arterial O2 difference than accountable by inert gas exchange.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hypoxic Pulmonary Vasoconstriction
Sylvester, J. T., Shimoda, L. A., Aaronson, P. I., & Ward, J. P. T. (2012) · Physiological Reviews · doi:10.1152/physrev.00041.2010 · Cited by 725
Arterial Blood Gases and Oxygen Content in Climbers on Mount Everest
Grocott, M. P. W., Martin, D. S., Levett, D. Z. H., McMorrow, R., Windsor, J., & Montgomery, H. E. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0801581 · Cited by 532
: what do we know, and what do we still need to know?
Levine, B. D. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2007.147629 · Cited by 431
Determinants of maximal oxygen uptake in severe acute hypoxia
Calbet, J. A. L., Boushel, R., Rådegran, G., Søndergaard, H., Wagner, P. D., & Saltin, B. (2003) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00155.2002 · Cited by 253
Self-citationIncrease in Pulmonary Ventilation–Perfusion Inequality with Age in Healthy Individuals
CARDÚS, J., BURGOS, F., DIAZ, O., ROCA, J., BARBERÁ, J. A., MARRADES, R. M., RODRIGUEZ-ROISIN, R., & WAGNER, P. D. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.156.2.9606016 · Cited by 165
Self-citation
Metadata
- Authors
- Torre-Bueno, J. R., Wagner, P. D., Saltzman, H. A., Gale, G. E., & Moon, R. E.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1985-03-01
- Volume
- 58
- Issue
- 3
- Pages
- 989-995
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2273749813
- Cited by
- 215
- References
- 0
- FWCI
- 3.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffusion limitation in normal humans during exercise at sea level and simulated altitude. https://app.cochat.ai/papers/10.1152/jappl.1985.58.3.989
- The paper
- Torre-Bueno, J. R., Wagner, P. D., Saltzman, H. A., Gale, G. E., & Moon, R. E. (1985). Diffusion limitation in normal humans during exercise at sea level and simulated altitude. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1985.58.3.989
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.