The DOI matches its Crossref record.
Separation of factors responsible for change in breathing pattern induced by instrumentation
Abstract
Employment of mouthpiece and noseclips (MP + NC) has repeatedly been shown to increase tidal volume (VT), but its effect on respiratory frequency (f) and its subsets is controversial. The mechanisms accounting for this alteration in breathing pattern are poorly understood and may include stimulation of oral or nasal sensory receptors or alteration in the route of breathing. In this study we demonstrated that use of a MP + NC, compared with nonobtrusive measurement with a calibrated respiratory inductive plethysmograph, alters the majority of the volume and time indexes of breathing pattern, with increases in minute ventilation (P less than 0.01), VT (P less than 0.001), inspiratory time (TI, P less than 0.05), expiratory time (TE, P less than 0.05), mean inspiratory flow (P less than 0.05), and mean expiratory flow (P less than 0.05) and a decrease in f(P less than 0.05). Separating the potential mechanisms we found that when the respiratory route was not altered, independent oral stimulation (using an occluded MP) or nasal stimulation (by applying paper clips to the alae nasi) did not change the breathing pattern. In contrast, obligatory oral breathing without additional stimulation of the oral or nasal sensory receptors caused increases in VT (P less than 0.05), TI (P less than 0.05), and TE (P less than 0.01) and a fall in f(P less than 0.05). Heating and humidifying the inspired air did not prevent the alteration in breathing pattern with a MP. Thus change in the respiratory route is the major determinant of the alteration in breathing pattern with a MP + NC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Emotions and respiratory patterns: review and critical analysis
Boiten, F. A., Frijda, N. H., & Wientjes, C. J. E. (1994) · International Journal of Psychophysiology · doi:10.1016/0167-8760(94)90027-2 · Cited by 462
The Pathophysiology of Hyperventilation Disorders
Gardner, W. N. (1996) · Chest · doi:10.1378/chest.109.2.516 · Cited by 312
Breathing pattern in humans: diversity and individuality
Benchetrit, G. (2000) · Respiration Physiology · doi:10.1016/s0034-5687(00)00154-7 · Cited by 288
Respiratory Changes in Response to Cognitive Load: A Systematic Review
Grassmann, M., Vlemincx, E., von Leupoldt, A., Mittelstädt, J. M., & Van den Bergh, O. (2016) · Neural Plasticity · doi:10.1155/2016/8146809 · Cited by 219
Anxiety and respiratory patterns: their relationship during mental stress and physical load
Masaoka, Y., & Homma, I. (1997) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(97)00052-4 · Cited by 188
Metadata
- Authors
- Perez, W., & Tobin, M. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1985-11-01
- Volume
- 59
- Issue
- 5
- Pages
- 1515-1520
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2175478431
- Cited by
- 165
- References
- 0
- FWCI
- 1.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Separation of factors responsible for change in breathing pattern induced by instrumentation. https://app.cochat.ai/papers/10.1152/jappl.1985.59.5.1515
- The paper
- Perez, W., & Tobin, M. J. (1985). Separation of factors responsible for change in breathing pattern induced by instrumentation. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1985.59.5.1515
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.