Effect of granulocyte depletion in a ventilated surfactant-depleted lung
The DOI matches its Crossref record.
Abstract
In a previous paper Cutz, Bryan et al. showed that in rabbits after repetitive lung lavage high-frequency oscillatory ventilation maintained excellent gas exchange and did not cause hyaline membrane formation (J. Appl. Physiol. 55: 131–138, 1983). In contrast, conventional mechanical ventilation had poor gas exchange and extensive hyaline membrane formation and we attributed these differences to mechanical barotrauma. However, we completely overlooked the large number of granulocytes in the damaged lung. To investigate this using the same model we have used mechanical ventilation on two groups of rabbits, one with normal granulocytes, the other depleted of granulocytes by pretreatment with nitrogen mustard. The nondepleted rabbits had poor gas exchange, a substantial protein leak into the lung and extensive hyaline membranes. The depleted animals had good gas exchange, a very small protein leak and no hyaline membranes. Repletion of granulocytes from donor rabbits lead to poor gas exchange and hyaline membrane formation. It is concluded that lung lavage causes prompt margination of granulocytes which become activated by the ongoing epithelial barotrauma of conventional ventilation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ventilator-induced Lung Injury: Lessons from Experimental Studies
DREYFUSS, D., & SAUMON, G. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.1.9604014 · Cited by 2,297
Ventilator-Induced Lung Injury
Slutsky, A. S., & Ranieri, V. M. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1208707 · Cited by 2,211
Ranieri, V. M., Suter, P. M., Tortorella, C., De Tullio, R., Dayer, J. M., Brienza, A., Bruno, F., & Slutsky, A. S. (1999) · JAMA · doi:10.1001/jama.282.1.54 · Cited by 1,908
Animal models of acute lung injury
Matute-Bello, G., Frevert, C. W., & Martin, T. R. (2008) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00010.2008 · Cited by 1,728
Tremblay, L., Valenza, F., Ribeiro, S. P., Li, J., & Slutsky, A. S. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119259 · Cited by 1,330
Contribution of Neutrophils to Acute Lung Injury
Grommes, J., & Soehnlein, O. (2011) · Molecular Medicine · doi:10.2119/molmed.2010.00138 · Cited by 1,313
Tidal ventilation at low airway pressures can augment lung injury.
Muscedere, J. G., Mullen, J. B., Gan, K., & Slutsky, A. S. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.5.8173774 · Cited by 1,244
Hickling, K. G., Henderson, S. J., & Jackson, R. (1990) · Intensive Care Medicine · doi:10.1007/bf01735174 · Cited by 933
Multiple System Organ Failure: Is Mechanical Ventilation a Contributing Factor?
SLUTSKY, A. S., & TREMBLAY, L. N. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.6.9709092 · Cited by 836
Cytokine-mediated inflammation in acute lung injury
Goodman, R. B., Pugin, J., Lee, J. S., & Matthay, M. A. (2003) · Cytokine & Growth Factor Reviews · doi:10.1016/s1359-6101(03)00059-5 · Cited by 688
Lung Injury Caused by Mechanical Ventilation
Slutsky, A. S. (1999) · Chest · doi:10.1378/chest.116.suppl_1.9s-a · Cited by 634
Invited Review: Mechanisms of ventilator-induced lung injury: a perspective
Dos Santos, C. C., & Slutsky, A. S. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.4.1645 · Cited by 458
Pugin, J., Verghese, G., Widmer, M.-C., & Matthay, M. A. (1999) · Critical Care Medicine · doi:10.1097/00003246-199902000-00036 · Cited by 421
The mercurial nature of neutrophils: still an enigma in ARDS?
Williams, A. E., & Chambers, R. C. (2014) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.00311.2013 · Cited by 415
Ventilator-induced lung injury: from the bench to the bedside
Tremblay, L. N., & Slutsky, A. S. (2006) · Intensive Care Medicine · doi:10.1007/s00134-005-2817-8 · Cited by 410
Ventilator-associated lung injury
Pinhu, L., Whitehead, T., Evans, T., & Griffiths, M. (2003) · The Lancet · doi:10.1016/s0140-6736(03)12329-x · Cited by 408
Critical role for CXCR2 and CXCR2 ligands during the pathogenesis of ventilator-induced lung injury
Belperio, J. A., Keane, M. P., Burdick, M. D., Londhe, V., Xue, Y. Y., Li, K., Phillips, R. J., & Strieter, R. M. (2002) · Journal of Clinical Investigation · doi:10.1172/jci0215849 · Cited by 366
Activation of human macrophages by mechanical ventilation in vitro
Pugin, J., Dunn, I., Jolliet, P., Tassaux, D., Magnenat, J.-L., Nicod, L. P., & Chevrolet, J.-C. (1998) · American Journal of Physiology-Lung Cellular and Molecular Physiology · doi:10.1152/ajplung.1998.275.6.l1040 · Cited by 352
TSCHUMPERLIN, D. J., OSWARI, J., & MARGULIES, A. S. S. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.2.9807003 · Cited by 347
Ventilator-induced lung injury:from the bench to the bedside
Tremblay, L. N., & Slutsky, A. S. (2009) · Applied Physiology in Intensive Care Medicine · doi:10.1007/978-3-642-01769-8_60 · Cited by 328
HICKLING, K. G. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.1.9905084 · Cited by 312
What Tidal Volumes Should Be Used in Patients without Acute Lung Injury?
Schultz, M. J., Haitsma, J. J., Slutsky, A. S., Gajic, O., & Warltier, D. C. (2007) · Anesthesiology · doi:10.1097/01.anes.0000267607.25011.e8 · Cited by 296
Ventilator-induced lung injury
Ricard, J., Dreyfuss, D., & Saumon, G. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00420103 · Cited by 276
Brief, Large Tidal Volume Ventilation Initiates Lung Injury and a Systemic Response in Fetal Sheep
Hillman, N. H., Moss, T. J. M., Kallapur, S. G., Bachurski, C., Pillow, J. J., Polglase, G. R., Nitsos, I., Kramer, B. W., & Jobe, A. H. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200701-051oc · Cited by 264
HELD, H.-D., BOETTCHER, S., HAMANN, L., & UHLIG, S. (2001) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.163.3.2003001 · Cited by 263
Surfactant dysfunction makes lungs vulnerable to repetitive collapse and reexpansion.
Taskar, V, John, J., Evander, E., Robertson, B., & Jonson, B. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.1.9001330 · Cited by 217
Permissive Hypercapnia in Acute Respiratory Failure
Bidani, A. (1994) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1994.03520120067033 · Cited by 215
Overview of ventilator-induced lung injury mechanisms
Lionetti, V., Recchia, F. A., & Marco Ranieri, V. (2005) · Current Opinion in Critical Care · doi:10.1097/00075198-200502000-00013 · Cited by 188
Sandhar, B. K., Niblett, D. J., Argiras, E. P., Dunnill, M. S., & Sykes, M. K. (1988) · Intensive Care Medicine · doi:10.1007/bf00263527 · Cited by 172
“Leucocyte depletion has been shown to reduce lung damage due to hyperoxia [22] and granulocyte depleted rabbits mechanically ventilated after lung lavage have been found not to form hyaline membranes [6].”
BackgroundACUTE LUNG INJURY AND ACUTE RESPIRATORY DISTRESS SYNDROME IN SEPSIS AND SEPTIC SHOCK
Fein, A. M., & Calalang-Colucci, M. G. (2000) · Critical Care Clinics · doi:10.1016/s0749-0704(05)70111-1 · Cited by 159
Imanaka, H., Shimaoka, M., Matsuura, N., Nishimura, M., Ohta, N., & Kiyono, H. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200102000-00029 · Cited by 159
Zeng, Z., Gong, H., Li, Y., Jie, K., Ding, C., Shao, Q., Liu, F., Zhan, Y., Nie, C., Zhu, W., et al. (2013) · Experimental Lung Research · doi:10.3109/01902148.2013.808285 · Cited by 128
Metadata
- Authors
- Kawano, T., Mori, S., Cybulsky, M., Burger, R., Ballin, A., Cutz, E., & Bryan, A. C.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1987-01-01
- Volume
- 62
- Issue
- 1
- Pages
- 27-33
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2156063750
- Cited by
- 275
- References
- 0
- FWCI
- 3.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.