H2O2 and cGMP may function as an O2 sensor in the pulmonary artery
The DOI matches its Crossref record.
Abstract
The effects of O2 tension on force in precontracted isolated pulmonary arterial smooth muscle from calf lungs was characterized to investigate the mechanism of O2 tension sensing. These arteries display a decrease in force with increasing O2 tension that is antagonized via inhibition of soluble guanylate cyclase activation by 10 microM methylene blue or inactivation of catalase by pretreatment with 50 mM 3-amino-1,2,4-triazole for 30 min. O2 tension-dependent relaxation is associated with an increase in intracellular H2O2 metabolism through catalase (detected as the peroxide-dependent inactivation of tissue catalase activity by aminotriazole) and cyclic guanosine 5'-monophosphate (cGMP), known mediators of relaxation in calf pulmonary arteries. Thus a recently reconstructed mechanism of activation of soluble guanylate cyclase involving the metabolism of H2O2 by catalase appears to function as an O2 tension sensor in pulmonary arteries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hypoxic Pulmonary Vasoconstriction
Sylvester, J. T., Shimoda, L. A., Aaronson, P. I., & Ward, J. P. T. (2012) · Physiological Reviews · doi:10.1152/physrev.00041.2010 · Cited by 725
Direct role for potassium channel inhibition in hypoxic pulmonary vasoconstriction
Post, J. M., Hume, J. R., Archer, S. L., & Weir, E. K. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.4.c882 · Cited by 451
Archer, S. L., Gomberg-Maitland, M., Maitland, M. L., Rich, S., Garcia, J. G. N., & Weir, E. K. (2008) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01324.2007 · Cited by 366
Diversity in Mitochondrial Function Explains Differences in Vascular Oxygen Sensing
Michelakis, E. D., Hampl, V., Nsair, A., Wu, X., Harry, G., Haromy, A., Gurtu, R., & Archer, S. L. (2002) · Circulation Research · doi:10.1161/01.res.0000024689.07590.c2 · Cited by 309
Pulmonary artery NADPH-oxidase is activated in hypoxic pulmonary vasoconstriction.
Marshall, C., Mamary, A. J., Verhoeven, A. J., & Marshall, B. E. (1996) · American Journal of Respiratory Cell and Molecular Biology · doi:10.1165/ajrcmb.15.5.8918370 · Cited by 257
NADPH oxidase: a universal oxygen sensor?
Jones, R. D., Hancock, J. T., & Morice, A. H. (2000) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(00)00320-8 · Cited by 162
Reactive oxygen species and the control of vascular function
Wolin, M. S. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01167.2008 · Cited by 133
Self-citationRedox regulation of responses to hypoxia and NO–cGMP signaling in pulmonary vascular pathophysiology
Wolin, M. S., Gupte, S. A., Mingone, C. J., Neo, B. H., Gao, Q., & Ahmad, M. (2010) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2010.05557.x · Cited by 17
Self-citation
Metadata
- Authors
- Burke-Wolin, T., & Wolin, M. S.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1989-01-01
- Volume
- 66
- Issue
- 1
- Pages
- 167-170
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2173972150
- Cited by
- 81
- References
- 0
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.