The DOI matches its Crossref record.
Initial blood pressure fall on stand up and exercise explained by changes in total peripheral resistance
Abstract
To elucidate the underlying mechanisms of the initial fall in blood pressure on standing upright from the supine position, we measured the beat-to-beat changes in intra-arterial pressure in eight healthy male subjects in response to standing. Changes in stroke volume, cardiac output, and total peripheral resistance were computed from the pressure waveform using a pulse contour method. To determine possible mechanisms for the changes observed on standing, similar measures were made on passive tilting and a brief (3-s) bout of cycle exercise. Standing elicited a transient 25% (23-mmHg) fall in mean blood pressure as a result of a 36% fall in total peripheral resistance. Head-up tilt elicited a gradual change in haemodynamic parameters, which reached plateau levels in 20-30 s. Cycling elicited a transient 17% (18-mmHg) fall in blood pressure and a 41% fall in total peripheral resistance. In addition, we measured right atrial and esophageal pressures in two subjects on standing and cycling and found a 10- to 15-mmHg rise in right atrial pressure without a corresponding change in esophageal pressure. This points to the cardiopulmonary reflex as the primary effector of peripheral vasodilation, but we cannot exclude the possibility that 1) local metabolic vasodilation and 2) central command-mediated cholinergic vasodilation contributed to the fall in vascular resistance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vinik, A. I., Maser, R. E., Mitchell, B. D., & Freeman, R. (2003) · Diabetes Care · doi:10.2337/diacare.26.5.1553 · Cited by 2,044
Computation of aortic flow from pressure in humans using a nonlinear, three-element model
Wesseling, K. H., Jansen, J. R., Settels, J. J., & Schreuder, J. J. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.5.2566 · Cited by 1,137
Self-citationFifteen years experience with finger arterial pressure monitoring: assessment of the technology
Imholz, B. (1998) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00067-4 · Cited by 834
Self-citationAssessment of cardiac output from systemic arterial pressure in humans
Romano, S. M., & Pistolesi, M. (2002) · Critical Care Medicine · doi:10.1097/00003246-200208000-00027 · Cited by 616
van Beek, A. H., Claassen, J. A., Rikkert, M. G. O., & Jansen, R. W. (2008) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2008.13 · Cited by 485
Metadata
- Authors
- Sprangers, R. L., Wesseling, K. H., Imholz, A. L., Imholz, B. P., & Wieling, W.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1991-02-01
- Volume
- 70
- Issue
- 2
- Pages
- 523-530
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2164620593
- Cited by
- 179
- References
- 0
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Initial blood pressure fall on stand up and exercise explained by changes in total peripheral resistance. https://app.cochat.ai/papers/10.1152/jappl.1991.70.2.523
- The paper
- Sprangers, R. L., Wesseling, K. H., Imholz, A. L., Imholz, B. P., & Wieling, W. (1991). Initial blood pressure fall on stand up and exercise explained by changes in total peripheral resistance. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1991.70.2.523
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.