The DOI matches its Crossref record.
Coarse-graining spectral analysis: new method for studying heart rate variability
Abstract
Heart rate variability (HRV) spectra are typically analyzed for the components related to low- (less than 0.15 Hz) and high- (greater than 0.15 Hz) frequency variations. However, there are very-low-frequency components with periods up to hours in HRV signals, which might smear short-term spectra. We developed a method of spectral analysis suitable for selectively extracting very-low-frequency components, leaving intact the low- and high-frequency components of interest in HRV spectral analysis. Computer simulations showed that those low-frequency components were well characterized by fractional Brownian motions (FBMs). If the scale invariant, or self-similar, property of FBMs is considered a new time series (x′) was constructed by sampling only every other point (course graining) of the original time series (x). Evaluation of the cross-power spectra between these two (Sxx′) showed that the power of the FBM components was preserved, whereas that of the harmonic components vanished. Subtraction of magnitude of Sxx from the autopower spectra of the original sequence emphasized only the harmonic components. Application of this method to HRV spectral analyses indicated that it might enable one to observe more clearly the low- and high-frequency components characteristic of autonomic control of heart rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
The Temporal Structures and Functional Significance of Scale-free Brain Activity
He, B. J., Zempel, J. M., Snyder, A. Z., & Raichle, M. E. (2010) · Neuron · doi:10.1016/j.neuron.2010.04.020 · Cited by 990
From space to Earth: Advances in human physiology from 20 years of bed rest studies (1986–2006)
Pavy-Le Traon, A., Heer, M., Narici, M. V., Rittweger, J., & Vernikos, J. (2007) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0474-z · Cited by 658
Separating Fractal and Oscillatory Components in the Power Spectrum of Neurophysiological Signal
Wen, H., & Liu, Z. (2016) · Brain Topography · doi:10.1007/s10548-015-0448-0 · Cited by 419
Metadata
- Authors
- Yamamoto, Y., & Hughson, R. L.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1991-09-01
- Volume
- 71
- Issue
- 3
- Pages
- 1143-1150
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2147052677
- Cited by
- 356
- References
- 0
- FWCI
- 7.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coarse-graining spectral analysis: new method for studying heart rate variability. https://app.cochat.ai/papers/10.1152/jappl.1991.71.3.1143
- The paper
- Yamamoto, Y., & Hughson, R. L. (1991). Coarse-graining spectral analysis: new method for studying heart rate variability. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1991.71.3.1143
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.