Input impedance and peripheral inhomogeneity of dog lungs
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Tracheal pressure, central airflow, and alveolar capsule pressures in cardiac lobes were measured in open-chest dogs during 0.1- to 20-Hz pseudorandom forced oscillations applied at the airway opening. In the interval 0.1–4.15 Hz, the input impedance data were fitted by four-parameter models including frequency-independent airway resistance and inertance and tissue parts featuring a marked negative frequency dependence of resistance and a slight elevation of elastance with frequency. The models gave good fits both in the control state and during histamine infusion. At the same time, the regional transfer impedances (alveolar pressure-to-central airflow ratios) showed intralobar and interlobar variabilities of similar degrees, which increased with frequency and were exaggerated during histamine infusion. Results of simulation studies based on a lung model consisting of a central airway and a number of peripheral units with airway and tissue parameters that were given independent wide distributions were in agreement with the experimental findings and showed that even an extremely inhomogeneous lung structure can produce virtually homogeneous mechanical behavior at the input.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the imperfect elasticity of lung tissue
Fredberg, J. J., & Stamenovic, D. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.67.6.2408 · Cited by 494
Self-citationPartitioning of pulmonary resistance in dogs: effect of tidal volume and frequency
Brusasco, V., Warner, D. O., Beck, K. C., RODARTE, J. R., & Rehder, K. (1989) · Journal of Applied Physiology · doi:10.1152/jappl.1989.66.3.1190 · Cited by 67
Heterogeneous lung emptying during forced expiration
McNamara, J. J., Castile, R. G., Glass, G. M., & Fredberg, J. J. (1987) · Journal of Applied Physiology · doi:10.1152/jappl.1987.63.4.1648 · Cited by 65
Self-citation
Cited by
Oostveen, E., MacLeod, D., Lorino, H., Farré, R., Hantos, Z., Desager, K., & Marchal, F. (2003) · European Respiratory Journal · doi:10.1183/09031936.03.00089403 · Cited by 1,302
Self-citationBeydon, N., Davis, S. D., Lombardi, E., Allen, J. L., Arets, H. G. M., Aurora, P., Bisgaard, H., Davis, G. M., Ducharme, F. M., Eigen, H., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200605-642st · Cited by 1,250
Self-citationTechnical standards for respiratory oscillometry
King, G. G., Bates, J., Berger, K. I., Calverley, P., de Melo, P. L., Dellacà, R. L., Farré, R., Hall, G. L., Ioan, I., Irvin, C. G., et al. (2020) · European Respiratory Journal · doi:10.1183/13993003.00753-2019 · Cited by 756
The role of fractional calculus in modeling biological phenomena: A review
Ionescu, C., Lopes, A., Copot, D., Machado, J. A. T., & Bates, J. H. T. (2017) · Communications in Nonlinear Science and Numerical Simulation · doi:10.1016/j.cnsns.2017.04.001 · Cited by 729
Measuring the lung function in the mouse: the challenge of size
Irvin, C. G., & Bates, J. H. (2003) · Respiratory Research · doi:10.1186/rr199 · Cited by 407
Metadata
- Authors
- Hantos, Z., Daroczy, B., Suki, B., Nagy, S., & Fredberg, J. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1992-01-01
- Volume
- 72
- Issue
- 1
- Pages
- 168-178
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2143645698
- Cited by
- 844
- References
- 3
- FWCI
- 3.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.