CoChat

Input impedance and peripheral inhomogeneity of dog lungs

Hantos, Z., Daroczy, B., Suki, B., Nagy, S., Fredberg, J. J. · 1992 · Journal of Applied Physiology
Cited by 844

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Tracheal pressure, central airflow, and alveolar capsule pressures in cardiac lobes were measured in open-chest dogs during 0.1- to 20-Hz pseudorandom forced oscillations applied at the airway opening. In the interval 0.1–4.15 Hz, the input impedance data were fitted by four-parameter models including frequency-independent airway resistance and inertance and tissue parts featuring a marked negative frequency dependence of resistance and a slight elevation of elastance with frequency. The models gave good fits both in the control state and during histamine infusion. At the same time, the regional transfer impedances (alveolar pressure-to-central airflow ratios) showed intralobar and interlobar variabilities of similar degrees, which increased with frequency and were exaggerated during histamine infusion. Results of simulation studies based on a lung model consisting of a central airway and a number of peripheral units with airway and tissue parameters that were given independent wide distributions were in agreement with the experimental findings and showed that even an extremely inhomogeneous lung structure can produce virtually homogeneous mechanical behavior at the input.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.1992.72.1.168

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Hantos, Z., Daroczy, B., Suki, B., Nagy, S., & Fredberg, J. J.
Venue
Journal of Applied Physiology
Published
1992-01-01
Volume
72
Issue
1
Pages
168-178
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2143645698
Cited by
844
References
3
FWCI
3.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.