Oxygen cost of exercise hyperpnea: measurement
The DOI matches its Crossref record.
Abstract
To quantitate the O2 cost of maximal exercise hyperpnea, we required eight healthy adult subjects to mimic, at rest, the important mechanical components of submaximal and maximal exercise hyperpnea. Expired minute ventilation (VE), transpulmonary and transdiaphragmatic (Pdi) pressures, and end-expiratory lung volume (EELV) were measured during exercise at 70 and 100% of maximal O2 uptake. At rest, subjects were given visual feedback of their exercise transpulmonary pressure-tidal volume loop (WV), breathing frequency, and EELV, which they mimicked repeatedly for 5 min per trial over several trials, while hypocapnia was prevented. The change in total body O2 uptake (VO2) was measured and presumed to represent the O2 cost of the hyperpnea. In 61 mimicking trials with VE of 115–167 l/min and WV of 124–544 J/min, VE, WV, duty cycle of the breath, and expiratory gastric pressure (Pga) integrated with respect to time (integral of Pga.dt/min) were not different from those observed during maximum exercise. integral of Pdi.dt/min was 14% less and EELV was 6% greater during maximum exercise than during mimicking. The O2 cost measurements within a subject were reproducible over 3–12 trials (coefficient of variation +/- 10% range 5–16%). The O2 costs of hyperpnea correlated highly and positively with VE and WV and less, but significantly, with integral of Pdi.dt and integral of Pga.dt. The O2 cost of VE rose out of proportion to the increasing hyperpnea, so that between 70 and 100% of maximal VO2 delta VO2/delta VE increased 40–60% (1.8 +/- 0.2 to 2.9 +/- 0.1 ml O2/l VE) as VE doubled.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Poole, D. C., & Jones, A. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100072 · Cited by 514
Influence of muscle fiber type and pedal frequency on oxygen uptake kinetics of heavy exercise
Barstow, T. J., Jones, A. M., Nguyen, P. H., & Casaburi, R. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.4.1642 · Cited by 448
Oxygen cost of exercise hyperpnea: implications for performance
Aaron, E. A., Seow, K. C., Johnson, B. D., & Dempsey, J. A. (1992) · Journal of Applied Physiology · doi:10.1152/jappl.1992.72.5.1818 · Cited by 377
Self-citationRespiratory mechanics during exercise in endurance‐trained men and women
Guenette, J. A., Witt, J. D., McKenzie, D. C., Road, J. D., & Sheel, A. W. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2006.126466 · Cited by 247
Smaller lungs in women affect exercise hyperpnea
McClaran, S. R., Harms, C. A., Pegelow, D. F., & Dempsey, J. A. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.6.1872 · Cited by 238
“(1) noted that subjects with significant expiratory flow limitation had the highest O2 cost per liter of V̇E, presumably because of the increase in expiratory resistance and turbulent airflow with more of the tidal breath in a compressed, smaller-diameter airway.”
BackgroundSelf-citation
Metadata
- Authors
- Aaron, E. A., Johnson, B. D., Seow, C. K., & Dempsey, J. A.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1992-05-01
- Volume
- 72
- Issue
- 5
- Pages
- 1810-1817
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1808632593
- Cited by
- 132
- References
- 0
- FWCI
- 7.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Oxygen cost of exercise hyperpnea: measurement. https://app.cochat.ai/papers/10.1152/jappl.1992.72.5.1810
- The paper
- Aaron, E. A., Johnson, B. D., Seow, C. K., & Dempsey, J. A. (1992). Oxygen cost of exercise hyperpnea: measurement. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1992.72.5.1810
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.