Cerebral oxygenation changes in response to motor stimulation
The DOI matches its Crossref record.
Abstract
We studied cerebral hemodynamic response to a sequential motor task in 56 subjects to investigate the time course and distribution of blood oxygenation changes as monitored by near-infrared spectroscopy (NIRS). To address whether response is modulated by different performance velocities, a group of subjects (n = 12) was examined while performing the motor task at 1, 2, and 3 Hz. The results demonstrate that 1) the NIRS response reflects localized changes in cerebral hemodynamics, 2) the response, consisting of an increase in oxygenated hemoglobin concentration [oxy-Hb] and a decrease in deoxygenated hemoglobin concentration ([deoxy-Hb]), is lateralized and increases in amplitude with higher performance rates, and 3) changes in [oxy-Hb] and [deoxy-Hb] differ in time course. Changes in [oxy-Hb] are biphasic, with a fast initial increase and a pronounced poststimulus undershoot. The stimulus-associated decrease in [deoxy-Hb] is monophasic, and response latency is greater. We conclude that NIRS is able to detect even small changes in cerebral hemodynamic response to functional stimulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
HomER: A review of time-series analysis methods for near-infrared spectroscopy of the brain
Huppert, T. J., Diamond, S. G., Franceschini, M. A., & Boas, D. A. (2009) · Applied Optics · doi:10.1364/ao.48.00d280 · Cited by 1,817
“Other areas of investigation have included the motor [26–29], prefrontal or cognitive [30–33], and language systems [34].”
BackgroundNon-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Self-citationStrangman, G., Culver, J. P., Thompson, J. H., & Boas, D. A. (2002) · NeuroImage · doi:10.1006/nimg.2002.1227 · Cited by 1,415
Beyond the Visible???Imaging the Human Brain With Light
Obrig, H., & Villringer, A. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200301000-00001 · Cited by 892
Self-citationBoas, D. A., Dale, A. M., & Franceschini, M. A. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.011 · Cited by 721
Spontaneous Low Frequency Oscillations of Cerebral Hemodynamics and Metabolism in Human Adults
Obrig, H., Neufang, M., Wenzel, R., Kohl, M., Steinbrink, J., Einhäupl, K., & Villringer, A. (2000) · NeuroImage · doi:10.1006/nimg.2000.0657 · Cited by 614
Self-citationLeff, D. R., Orihuela-Espina, F., Elwell, C. E., Athanasiou, T., Delpy, D. T., Darzi, A. W., & Yang, G.-Z. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.058 · Cited by 484
Herold, F., Wiegel, P., Scholkmann, F., & Müller, N. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120466 · Cited by 482
Suto, T., Fukuda, M., Ito, M., Uehara, T., & Mikuni, M. (2004) · Biological Psychiatry · doi:10.1016/j.biopsych.2003.09.008 · Cited by 434
Cerebral blood flow and metabolism during exercise
Ide, K., & Secher, N. H. (2000) · Progress in Neurobiology · doi:10.1016/s0301-0082(99)00057-x · Cited by 409
Cerebral perturbations provoked by prolonged exercise
Nybo, L., & Secher, N. H. (2004) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2004.03.005 · Cited by 398
“…spectroscopy (NIRS) studies reveal that motor activation (with the exception of maximal whole-body exercise; Section 4.1.1) increases oxygenated and decreases deoxygenated haemoglobin concentrations in cortical motor areas (Obrig et al., 1996; Madsen and Secher, 1999; Ide and Secher, 2000).”
BackgroundInfluentialThe reticular-activating hypofrontality (RAH) model of acute exercise
Dietrich, A., & Audiffren, M. (2011) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2011.02.001 · Cited by 365
Non-invasive NIR spectroscopy of human brain function during exercise
Perrey, S. (2008) · Methods · doi:10.1016/j.ymeth.2008.04.005 · Cited by 346
Illuminating the BOLD signal: combined fMRI–fNIRS studies
Steinbrink, J., Villringer, A., Kempf, F., Haux, D., Boden, S., & Obrig, H. (2006) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2005.12.034 · Cited by 334
Self-citationDunn, A. K., Devor, A., Bolay, H., Andermann, M. L., Moskowitz, M. A., Dale, A. M., & Boas, D. A. (2003) · Optics Letters · doi:10.1364/ol.28.000028 · Cited by 333
Rooks, C. R., Thom, N. J., McCully, K. K., & Dishman, R. K. (2010) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.06.002 · Cited by 324
Neuroergonomics: a review of applications to physical and cognitive work
Mehta, R. K., & Parasuraman, R. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00889 · Cited by 306
Frontal lobe function in bipolar disorder: A multichannel near-infrared spectroscopy study
Kameyama, M., Fukuda, M., Yamagishi, Y., Sato, T., Uehara, T., Ito, M., Suto, T., & Mikuni, M. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.07.025 · Cited by 279
Jasdzewski, G., Strangman, G., Wagner, J., Kwong, K. K., Poldrack, R. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00311-2 · Cited by 277
Franceschini, M. A., Fantini, S., Thompson, J. H., Culver, J. P., & Boas, D. A. (2003) · Psychophysiology · doi:10.1111/1469-8986.00057 · Cited by 275
Mehagnoul‐Schipper, D. J., van der Kallen, B. F. W., Colier, W. N. J. M., van der Sluijs, M. C., van Erning, L. J. T. O., Thijssen, H. O. M., Oeseburg, B., Hoefnagels, W. H. L., & Jansen, R. W. M. M. (2002) · Human Brain Mapping · doi:10.1002/hbm.10026 · Cited by 264
“…changes in deoxyhemoglobin concentration ([HHb]), in response to various stimuli including visual, auditory, and motor stimuli [Colier et al., 1997, 1999; Kleinschmidt et al., 1996; Mehagnoul-Schipper et al., 2000; Obrig et al., 1996, 2000; Rao et al., 1993; van der Kallen et al., 1998].”
BackgroundMethodNear-infrared spectroscopy: does it function in functional activation studies of the adult brain?
Obrig, H., Wenzel, R., Kohl, M., Horst, S., Wobst, P., Steinbrink, J., Thomas, F., & Villringer, A. (2000) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(99)00048-3 · Cited by 264
Self-citationDetermining changes in NIR absorption using a layered model of the human head
Steinbrink, J., Wabnitz, H., Obrig, H., Villringer, A., & Rinneberg, H. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/320 · Cited by 259
Self-citationPositive effects of acute and moderate physical exercise on cognitive function
Kashihara, K., Maruyama, T., Murota, M., & Nakahara, Y. (2009) · Journal of PHYSIOLOGICAL ANTHROPOLOGY · doi:10.2114/jpa2.28.155 · Cited by 238
On-line optical imaging of the human brain with 160-ms temporal resolution
Franceschini, M. A., Toronov, V., Filiaci, M. E., Gratton, E., & Fantini, S. (2000) · Optics Express · doi:10.1364/oe.6.000049 · Cited by 237
Multimodal assessment of cortical activation during apple peeling by NIRS and fMRI
Okamoto, M., Dan, H., Shimizu, K., Takeo, K., Amita, T., Oda, I., Konishi, I., Sakamoto, K., Isobe, S., Suzuki, T., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.12.003 · Cited by 224
“Moreover, NIRS is more robust to body motion than other neuroimaging modalities and has proven to be effective in evaluating motor functions (Colier et al., 1999; Hirth et al., 1996; Maki et al., 1995; Obrig et al., 1996; Watanabe et al., 1996).”
BackgroundSato, H., Hirabayashi, Y., Tsubokura, H., Kanai, M., Ashida, T., Konishi, I., Uchida‐Ota, M., Konishi, Y., & Maki, A. (2012) · Human Brain Mapping · doi:10.1002/hbm.21350 · Cited by 184
“Similar patterns have been commonly observed in a number of NIRS studies on adults [Obrig et al., 1996, 2000; Sato et al., 1999, 2005], but physiological clarification is one of challenges that should be addressed in the future.”
ResultCerebral oxygenation declines at exercise intensities above the respiratory compensation threshold
Bhambhani, Y., Malik, R., & Mookerjee, S. (2007) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2006.08.009 · Cited by 184
Prefrontal hemodynamic changes produced by anodal direct current stimulation
Merzagora, A. C., Foffani, G., Panyavin, I., Mordillo-Mateos, L., Aguilar, J., Onaral, B., & Oliviero, A. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.10.044 · Cited by 182
“…by nearinfrared spectroscopy, could be considered a good index of rCBF variations. fNIRS can therefore provide metabolic information without invasive intervention and it is able to detect even small changes in the cerebral hemodynamic response to functional stimulation (Obrig et al., 1996).”
Metadata
- Authors
- Obrig, H., Hirth, C., Junge-Hulsing, J. G., Doge, C., Wolf, T., Dirnagl, U., & Villringer, A.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1996-09-01
- Volume
- 81
- Issue
- 3
- Pages
- 1174-1183
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W1921438975
- Cited by
- 227
- References
- 0
- FWCI
- 7.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.