The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Ventilatory response to exercise in subjects breathing CO2 or HeO2
Abstract
Babb, T. G. Ventilatory response to exercise in subjects breathing CO 2 or HeO 2. J. Appl. Physiol. 82(3): 746–754, 1997.—To investigate the effects of mechanical ventilatory limitation on the ventilatory response to exercise, eight older subjects with normal lung function were studied. Each subject performed graded cycle ergometry to exhaustion once while breathing room air; once while breathing 3% CO 2-21% O 2-balance N 2; and once while breathing HeO 2 (79% He and 21% O 2). Minute ventilation (V˙e) and respiratory mechanics were measured continuously during each 1-min increment in work rate (10 or 20 W). Data were analyzed at rest, at ventilatory threshold (VTh), and at maximal exercise. When the subjects were breathing 3% CO 2, there was an increase ( P < 0.001) inV˙e at rest and at VTh but not during maximal exercise. When the subjects were breathing HeO 2,V˙e was increased ( P < 0.05) only during maximal exercise (24 ± 11%). The ventilatory response to exercise below VTh was greater only when the subjects were breathing 3% CO 2( P < 0.05). Above VTh, the ventilatory response when the subjects were breathing HeO 2 was greater than when breathing 3% CO 2( P < 0.01). Flow limitation, as percent of tidal volume, during maximal exercise was greater ( P < 0.01) when the subjects were breathing CO 2 (22 ± 12%) than when breathing room air (12 ± 9%) or when breathing HeO 2 (10 ± 7%) ( n = 7). End-expiratory lung volume during maximal exercise was lower when the subjects were breathing HeO 2 than when breathing room air or when breathing CO 2( P < 0.01). These data indicate that older subjects have little reserve for accommodating an increase in ventilatory demand and suggest that mechanical ventilatory constraints influence both the magnitude of V˙eduring maximal exercise and the regulation ofV˙e and respiratory mechanics during heavy-to-maximal exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It follows that older individuals have a reduced reserve for accommodating increases in ventilatory demand during dynamic exercise (1).”
From The effects of age and sex on mechanical ventilatory constraint and dyspnea during exercise in healthy humans (2018) · cites this paper as [1]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanical Constraints on Exercise Hyperpnea in a Fit Aging Population
Johnson, B. D., Reddan, W. G., Seow, K. C., & Dempsey, J. A. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/143.5_pt_1.968 · Cited by 150
5 Demand vs. Capacity in the Aging Pulmonary System
JOHNSON, B. D., & DEMPSEY, J. A. (1991) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-199101000-00005 · Cited by 97
Research works printed but not linked: 20
- American Thoracic Society, 1986, Am. Rev. Respir. Dis., 133, 1205
- 10.1164/ajrccm/136.5.1285 · DOI · Paper page
- Babb T. G., 1994, Am. J. Respir. Crit. Care Med., 149, A782
- 10.1152/jappl.1991.70.2.715 · DOI
- 10.1152/jappl.1982.53.5.1184 · DOI · Paper page
- 10.1152/jappl.1969.27.5.597 · DOI
- 10.1152/jappl.1980.48.6.1065 · DOI
- 10.1111/j.1748-1716.1984.tb07421.x · DOI
- 10.1152/jappl.1985.59.2.365 · DOI
- 10.1152/jappl.1992.73.3.874 · DOI · Paper page
- Knudson R. J., 1976, Am. Rev. Respir. Dis., 113, 587
- 10.1172/JCI104336 · DOI · Paper page
- 10.1152/jappl.1963.18.3.497 · DOI
- 10.1172/JCI106015 · DOI
- 10.1152/jappl.1992.73.2.591 · doi:10.1152/jappl.1992.73.2.591
- 10.1152/jappl.1995.78.2.555 · doi:10.1152/jappl.1995.78.2.555
- 10.1007/BF00422446 · DOI
- 10.1152/jappl.1980.49.3.506 · DOI
- 10.1016/0034-5687(82)90116-5 · DOI
- 10.1152/jappl.1984.57.6.1773 · DOI · Paper page
Cited by
ATS/ACCP statement on cardiopulmonary exercise testing
(2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.167.2.211 · Cited by 3,026
ATS/ACCP statement on cardiopulmonary exercise testing
Ross, R. M. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.167.10.950 · Cited by 2,073
Emerging Concepts in the Evaluation of Ventilatory Limitation During Exercise
Johnson, B. D., Weisman, I. M., Zeballos, R. J., & Beck, K. C. (1999) · Chest · doi:10.1378/chest.116.2.488 · Cited by 363
Palange, P., Valli, G., Onorati, P., Antonucci, R., Paoletti, P., Rosato, A., Manfredi, F., & Serra, P. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01207.2003 · Cited by 162
Fat Distribution and End-Expiratory Lung Volume in Lean and Obese Men and Women
Babb, T. G., Wyrick, B. L., DeLorey, D. S., Chase, P. J., & Feng, M. Y. (2008) · Chest · doi:10.1378/chest.07-1728 · Cited by 136
Self-citation
Metadata
- Authors
- Babb, T. G.
- Affiliations
- Institute for Exercise and Environmental Medicine, Presbyterian Hospital of Dallas and The University of Texas Southwestern Medical Center, Dallas, Texas 77231
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1997-03-01
- Volume
- 82
- Issue
- 3
- Pages
- 746-754
- ISSN
- 8750-7587
- 1522-1601
- Cited by
- 79
- References
- 2
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.