Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 258

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Impact of controlling shear rate on flow-mediated dilation responses in the brachial artery of humans

Pyke, Kyra E., Dwyer, Erin M., Tschakovsky, Michael E.·2004·Journal of Applied Physiology

Abstract

The reactive hyperemia test (RHtest) evokes a transient increase in shear stress as a stimulus for endothelial-dependent flow-mediated vasodilation (EDFMD). We developed a noninvasive method to create controlled elevations in brachial artery (BA) shear rate (SR, estimate of shear stress), controlled hyperemia test (CHtest), and assessed the impact of this vs. the RHtest approach on EDFMD. Eight healthy subjects participated in two trials of each test on 3 separate days. For the CHtest, SR was step increased from 8 to 50 s−1, created by controlled release of BA compression during forearm heating. For the RHtest, transient increases in SR were achieved after 5 min of forearm occlusion. BA diameter and blood flow velocity (ultrasound) were measured upstream of compression and occlusion sites. Both tests elicited significant dilation (RHtest: 6.33 ± 3.12%; CHtest: 3.00 ± 1.05%). The CHtest resulted in 1) reduced between-subject SR and EDFMD variability vs. the RHtest [SR coefficient of variation (CV): 4.9% vs. 36.6%; EDFMD CV: 36.16% vs. 51.80%] and 2) virtual elimination of the impact of BA diameter on the peak EDFMD response (peak EDFMD vs. baseline diameter for RHtest, r 2 = 0.64, P < 0.01, vs. CHtest, r 2 = 0.14, P < 0.01). Normalization of the RHtest EDFMD response to the magnitude of the SR stimulus eliminated test differences in between-subject response variability. Reductions in trial-to-trial and day-to-day SR variability with the CHtest did not reduce EDFMD variability. Between-subject SR variability contributes to EDFMD variability with the RHtest. SR controls with the CHtest or RHtest response normalization are essential for examining EDFMD between groups differing in baseline arterial diameter.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.01245.2003

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 258

Metadata

Authors
Pyke, K. E., Dwyer, E. M., & Tschakovsky, M. E.
Venue
Journal of Applied Physiology
Published
2004-08
Volume
97
Issue
2
Pages
499-508
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2098817685
Cited by
258
References
2
FWCI
7.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impact of controlling shear rate on flow-mediated dilation responses in the brachial artery of humans. https://app.cochat.ai/papers/10.1152/japplphysiol.01245.2003
The paper
Pyke, K. E., Dwyer, E. M., & Tschakovsky, M. E. (2004). Impact of controlling shear rate on flow-mediated dilation responses in the brachial artery of humans. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.01245.2003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.