The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Nonisometric behavior of fascicles during isometric contractions of a human muscle
Abstract
Fascicle length, pennation angle, and tendon elongation of the human tibialis anterior were measured in vivo by ultrasonography. Subjects ( n = 9) were requested to develop isometric dorsiflexion torque gradually up to maximal at the ankle joint angle of 20° plantarflexion from the anatomic position. Fascicle length shortened from 90 ± 7 to 76 ± 7 (SE) mm, pennation angle increased from 10 ± 1 to 12 ± 1°, and tendon elongation increased up to 15 ± 2 mm with graded force development up to maximum. The tendon stiffness increased with increasing tendon force from 10 N/mm at 0–20 N to 32 N/mm at 240–260 N. Young’s modulus increased from 157 MPa at 0–20 N to 530 MPa at 240–260 N. It can be concluded that, in isometric contractions of a human muscle, mechanical work, some of which is absorbed by the tendinous tissue, is generated by the shortening of muscle fibers and that ultrasonography can be used to determine the stiffness and Young’s modulus for human tendons.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control.
Zajac, F. E. (1989) · PubMed · Cited by 3,673
The variation in isometric tension with sarcomere length in vertebrate muscle fibres
Gordon, A. M., Huxley, A. F., & Julian, F. J. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp007909 · Cited by 3,152
Narici, M. V., Binzoni, T., Hiltbrand, E., Fasel, J., Terrier, F., & Cerretelli, P. (1996) · The Journal of Physiology · doi:10.1113/jphysiol.1996.sp021685 · Cited by 555
Muscle fiber architecture in the human lower limb
Friederich, J. A., & Brand, R. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90373-b · Cited by 548
Muscle-fiber pennation angles are greater in hypertrophied than in normal muscles
Kawakami, Y., Abe, T., & Fukunaga, T. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.6.2740 · Cited by 518
Self-citationDetermination of fascicle length and pennation in a contracting human muscle in vivo
Fukunaga, T., Ichinose, Y., Ito, M., Kawakami, Y., & Fukashiro, S. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.1.354 · Cited by 452
Self-citationBIOMECHANICS OF LIGAMENTS AND TENDONS
L, D., Grood, E. S., Noyes, F. R., & Zernicke, R. E. (1978) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-197800060-00005 · Cited by 402
Why are mammalian tendons so thick?
KER, R. F., ALEXANDER, R. M., & BENNETT, M. B. (1988) · Journal of Zoology · doi:10.1111/j.1469-7998.1988.tb02432.x · Cited by 377
Griffiths, R. I. (1991) · The Journal of Physiology · doi:10.1113/jphysiol.1991.sp018547 · Cited by 370
Dynamic Tensile Properties of the Plantaris Tendon of Sheep (Ovis Aries)
Ker, R. F. (1981) · Journal of Experimental Biology · doi:10.1242/jeb.93.1.283 · Cited by 345
Cited by
Role of Extracellular Matrix in Adaptation of Tendon and Skeletal Muscle to Mechanical Loading
KJÆR, M. (2004) · Physiological Reviews · doi:10.1152/physrev.00031.2003 · Cited by 1,586
Measurement of muscle contraction with ultrasound imaging
Hodges, P. W., Pengel, L. H. M., Herbert, R. D., & Gandevia, S. C. (2003) · Muscle & Nerve · doi:10.1002/mus.10375 · Cited by 816
Bojsen-Møller, J., Magnusson, S. P., Rasmussen, L. R., Kjaer, M., & Aagaard, P. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01305.2004 · Cited by 532
“The longitudinal displacement of such fixed points during graded contractions was considered to represent the magnitude of deformation of the combined aponeurosis and free tendon distal to this point (11, 18, 23, 40, 42).”
BackgroundMethodInfluentialIn vivo human tendon mechanical properties
Maganaris, C. N., & Paul, J. P. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.00307.x · Cited by 494
Effect of strength training on human patella tendon mechanical properties of older individuals
Reeves, N. D., Maganaris, C. N., & Narici, M. V. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2002.035576 · Cited by 484
Effect of strength training on human patella tendon mechanical properties of older individuals
Reeves, N. D., Maganaris, C. N., & Narici, M. V. (2003) · The Journal of Physiology · doi:10.1111/j..2003.t01-1-00971.x · Cited by 484
Heckman, C. J., & Enoka, R. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100087 · Cited by 414
Load‐displacement properties of the human triceps surae aponeurosis in vivo
Magnusson, S. P., Aagaard, P., Rosager, S., Dyhre‐Poulsen, P., & Kjaer, M. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0277j.x · Cited by 407
Influence of static stretching on viscoelastic properties of human tendon structures in vivo
Kubo, K., Kanehisa, H., Kawakami, Y., & Fukunaga, T. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.520 · Cited by 397
Self-citationSkeletal muscle design to meet functional demands
Lieber, R. L., & Ward, S. R. (2011) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2010.0316 · Cited by 377
Influence of elastic properties of tendon structures on jump performance in humans
Kubo, K., Kawakami, Y., & Fukunaga, T. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.6.2090 · Cited by 352
Self-citationRosager, S., Aagaard, P., Dyhre‐Poulsen, P., Neergaard, K., Kjaer, M., & Magnusson, S. P. (2002) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2002.120205.x · Cited by 317
Rehabilitative Ultrasound Imaging of the Abdominal Muscles
Teyhen, D. S., Gill, N. W., Whittaker, J. L., Henry, S. M., Hides, J. A., & Hodges, P. (2007) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2007.2558 · Cited by 265
Mechanical properties of tendon and aponeurosis of human gastrocnemius muscle in vivo
Muramatsu, T., Muraoka, T., Takeshita, D., Kawakami, Y., Hirano, Y., & Fukunaga, T. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.5.1671 · Cited by 262
Self-citationIntrinsic Risk Factors for the Development of Achilles Tendon Overuse Injury: A Prospective Study
Mahieu, N. N., Witvrouw, E., Stevens, V., Van Tiggelen, D., & Roget, P. (2006) · The American Journal of Sports Medicine · doi:10.1177/0363546505279918 · Cited by 260
Mechanics of the normal woman's breast
Gefen, A., & Dilmoney, B. (2007) · Technology and Health Care · doi:10.3233/thc-2007-15404 · Cited by 257
The structure and functional significance of variations in the connective tissue within muscle
Purslow, P. P. (2002) · Comparative Biochemistry and Physiology Part A: Molecular & Integrative Physiology · doi:10.1016/s1095-6433(02)00141-1 · Cited by 255
Anatomical predictors of maximum isometric and concentric knee extensor moment
Blazevich, A. J., Coleman, D. R., Horne, S., & Cannavan, D. (2009) · European Journal of Applied Physiology · doi:10.1007/s00421-008-0972-7 · Cited by 176
“Measurements could not be reliably obtained during muscle contraction because the time required to set the appropriate alignment of the ultrasound transducer caused significant fatigue in the subjects; significant rotation of the fascicles occurs from rest to maximal contraction ( Ito et al. 1998 ), so the transducer…”
BackgroundEffect of Static and Ballistic Stretching on the Muscle-Tendon Tissue Properties
MAHIEU, N. N., MCNAIR, P., DE MUYNCK, M., STEVENS, V., BLANCKAERT, I., SMITS, N., & WITVROUW, E. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000247004.40212.f7 · Cited by 169
Tendon properties in relation to muscular activity and physical training
Magnusson, S. P., Hansen, P., & Kjær, M. (2003) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2003.00308.x · Cited by 166
Muscle–tendon tissue properties in the hypermobility type of Ehlers‐Danlos syndrome
Rombaut, L., Malfait, F., De Wandele, I., Mahieu, N., Thijs, Y., Segers, P., De Paepe, A., & Calders, P. (2012) · Arthritis Care & Research · doi:10.1002/acr.21592 · Cited by 71
Influence of contractile force on the architecture and morphology of the quadriceps femoris
Massey, G., Evangelidis, P., & Folland, J. (2015) · Experimental Physiology · doi:10.1113/ep085360 · Cited by 42
Metadata
- Authors
- Ito, M., Kawakami, Y., Ichinose, Y., Fukashiro, S., & Fukunaga, T.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1998-10-01
- Volume
- 85
- Issue
- 4
- Pages
- 1230-1235
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2107910247
- Cited by
- 258
- References
- 33
- FWCI
- 7.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.