A technique to measure the ability of the human nose to warm and humidify air
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
To assess the ability of the nose to warm and humidify inhaled air, we developed a nasopharyngeal probe and measured the temperature and humidity of air exiting the nasal cavity. We delivered cold, dry air (19–1°C, <10% relative humidity) or hot, humid air (37°C, >90% relative humidity) to the nose via a nasal mask at flow rates of 5, 10, and 20 l/min. We used a water gradient across the nose (water content in nasopharynx minus water content of delivered air) to assess nasal function. We studied the characteristics of nasal air conditioning in 22 asymptomatic, seasonally allergic subjects (out of their allergy season) and 11 nonallergic normal subjects. Inhalation of hot, humid air at increasingly higher flow rates had little effect on both the relative humidity and the temperature of air in the nasopharynx. In both groups, increasing the flow of cold, dry air lowered both the temperature and the water content of the inspired air measured in the nasopharynx, although the relative humidity remained at 100%. Water gradient values obtained during cold dry air challenges on separate days showed reproducibility in both allergic and nonallergic subjects. After exposure to cold, dry air, the water gradient was significantly lower in allergic than in nonallergic subjects (1,430 ± 45 vs. 1,718 ± 141 mg; P = 0.02), suggesting an impairment in their ability to warm and humidify inhaled air.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Theoretical Model of Localized Heat and Water Vapor Transport in the Human Respiratory Tract
Hanna, L. M., & Scherer, P. W. (1986) · Journal of Biomechanical Engineering · doi:10.1115/1.3138574 · Cited by 82 · cited 2×
“On the basis of a theoretical model, Hanna and Scherer (12) predict that the blood temperature distribution along the airway wall and the total cross-sectional area and perimeter of the nasal cavity are the two most important parameters of the human air conditioning response.”
Background
Cited by
Nishimura, M. (2016) · Respiratory Care · doi:10.4187/respcare.04577 · Cited by 476
The dichotomy of relative humidity on indoor air quality
Wolkoff, P., & Kjærgaard, S. K. (2007) · Environment International · doi:10.1016/j.envint.2007.04.004 · Cited by 260
Airway injury as a mechanism for exercise-induced bronchoconstriction in elite athletes
Anderson, S. D., & Kippelen, P. (2008) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2008.05.001 · Cited by 237
“The ability to return water to the airway surface, however, is likely to be different for the healthy and the inflamed lower airway, just as it is in the upper airway.(11) In healthy persons the upper limit of the decrease in FEV1 is less than 10% in response to breathing dry air at high flows, and the response can be…”
BackgroundThe Air-Conditioning Capacity of the Human Nose
Naftali, S., Rosenfeld, M., Wolf, M., & Elad, D. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-2513-4 · Cited by 193
Air-conditioning in the human nasal cavity
Elad, D., Wolf, M., & Keck, T. (2008) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2008.05.002 · Cited by 193
Metadata
- Authors
- Rouadi, P., Baroody, F. M., Abbott, D., Naureckas, E., Solway, J., & Naclerio, R. M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1999-07-01
- Volume
- 87
- Issue
- 1
- Pages
- 400-406
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2133503297
- Cited by
- 129
- References
- 1
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A technique to measure the ability of the human nose to warm and humidify air. https://app.cochat.ai/papers/10.1152/jappl.1999.87.1.400
- The paper
- Rouadi, P., Baroody, F. M., Abbott, D., Naureckas, E., Solway, J., & Naclerio, R. M. (1999). A technique to measure the ability of the human nose to warm and humidify air. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1999.87.1.400
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.