The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Measurement of fat mass using DEXA: a validation study in elderly adults
Abstract
The accuracy of total body fat mass and leg fat mass measurements by fan-beam dual-energy X-ray absorptiometry (DEXA) was assessed in 60 healthy elderly subjects (aged 70–79 yr). Total fat and leg fat mass at four leg regions (total leg, thigh, midthigh, and calf) were measured with the QDR 4500A (Hologic, Waltham, MA). The four-compartment model and multislice computed tomography scans were selected as criterion methods for total fat and leg fat mass, respectively. Total fat mass from DEXA was positively associated with fat mass from the four-compartment model with a standard error of the estimate ranging from 1.4 to 1.6 kg. DEXA fan-beam tended to overestimate fat mass for total leg and total thigh fat mass, whereas only marginal differences in fat mass measurements at the midthigh and calf were demonstrated (≤0.08 kg, P< 0.0005). Although there were significant differences between DEXA fan beam and the criterion methods, these differences were of small magnitude, suggesting that DEXA is an accurate method for measurement of fat mass for the elderly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Body composition in elderly people: effect of criterion estimates on predictive equations
Baumgartner, R., Heymsfield, S., Lichtman, S., Wang, J., & Pierson, R. (1991) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/53.6.1345 · Cited by 257
Preliminary evidence that DEXA provides an accurate assessment of body composition
Kohrt, W. M. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.372 · Cited by 186
Cited by
Studenski, S. A., Peters, K. W., Alley, D. E., Cawthon, P. M., McLean, R. R., Harris, T. B., Ferrucci, L., Guralnik, J. M., Fragala, M. S., Kenny, A. M., et al. (2014) · The Journals of Gerontology: Series A · doi:10.1093/gerona/glu010 · Cited by 2,545
Garvey, W. T., Mechanick, J. I., Brett, E. M., Garber, A. J., Hurley, D. L., Jastreboff, A. M., Nadolsky, K., Pessah-Pollack, R., & Plodkowski, R. (2016) · Endocrine Practice · doi:10.4158/ep161365.gl · Cited by 1,914
Houston, D. K., Nicklas, B. J., Ding, J., Harris, T. B., Tylavsky, F. A., Newman, A. B., Lee, J. S., Sahyoun, N. R., Visser, M., & Kritchevsky, S. B. (2008) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/87.1.150 · Cited by 1,214
Self-citationSarcopenia: alternative definitions and associations with lower extremity function
Newman, A. B., Kupelian, V., Visser, M., Simonsick, E., Goodpaster, B., Nevitt, M., Kritchevsky, S. B., Tylavsky, F. A., Rubin, S. M., Harris, T. B., et al. (2003) · Journal of the American Geriatrics Society · doi:10.1046/j.1532-5415.2003.51534.x · Cited by 981
Self-citationLong-Term Calorie Restriction Is Highly Effective in Reducing the Risk for Atherosclerosis in Humans
Fontana, L., Meyer, T. E., Klein, S., & Holloszy, J. O. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0308291101 · Cited by 902
Metadata
- Authors
- Salamone, L. M., Fuerst, T., Visser, M., Kern, M., Lang, T., Dockrell, M., Cauley, J. A., Nevitt, M., Tylavsky, F., & Lohman, T. G.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2000-07-01
- Volume
- 89
- Issue
- 1
- Pages
- 345-352
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2123798888
- Cited by
- 233
- References
- 3
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of fat mass using DEXA: a validation study in elderly adults. https://app.cochat.ai/papers/10.1152/jappl.2000.89.1.345
- The paper
- Salamone, L. M., Fuerst, T., Visser, M., Kern, M., Lang, T., Dockrell, M., Cauley, J. A., Nevitt, M., Tylavsky, F., & Lohman, T. G. (2000). Measurement of fat mass using DEXA: a validation study in elderly adults. Journal of Applied Physiology. https://doi.org/10.1152/jappl.2000.89.1.345
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.