CoChat

Pulmonary gas exchange during exercise in women: effects of exercise type and work increment

Hopkins, Susan R., Barker, Rebecca C., Brutsaert, Tom D., Gavin, Timothy P., Entin, Pauline, Olfert, Ivan M., Veisel, Susan, Wagner, Peter D. · 2000 · Journal of Applied Physiology
Cited by 110

The DOI matches its Crossref record.

Abstract

Exercise-induced arterial hypoxemia (EIAH) has been reported in male athletes, particularly during fast-increment treadmill exercise protocols. Recent reports suggest a higher incidence in women. We hypothesized that 1-min incremental (fast) running (R) protocols would result in a lower arterial Po 2 (Pa O 2 ) than 5-min increment protocols (slow) or cycling exercise (C) and that women would experience greater EIAH than previously reported for men. Arterial blood gases, cardiac output, and metabolic data were obtained in 17 active women [mean maximal O 2 uptake (V˙o 2 max) = 51 ml · kg−1 · min−1]. They were studied in random order (C or R), with a fastV˙o 2 max protocol. After recovery, the women performed 5 min of exercise at 30, 60, and 90% ofV˙o 2 max (slow). One week later, the other exercise mode (R or C) was similarly studied. There were no significant differences in V˙o 2 max between R and C. Pulmonary gas exchange was similar at rest, 30%, and 60% of V˙o 2 max. At 90% ofV˙o 2 max, Pa O 2 was lower during R (mean ± SE = 94 ± 2 Torr) than during C (105 ± 2 Torr, P < 0.0001), as was ventilation (85.2 ± 3.8 vs. 98.2 ± 4.4 l/min btps, P < 0.0001) and cardiac output (19.1 ± 0.6 vs. 21.1 ± 1.0 l/min, P < 0.001). Arterial Pco 2 (32.0 ± 0.5 vs. 30.0 ± 0.6 Torr, P < 0.001) and alveolar-arterial O 2 difference (A-aDo 2; 22 ± 2 vs. 16 ± 2 Torr, P < 0.0001) were greater during R. Pa O 2 and A-aDo 2 were similar between slow and fast. Nadir Pa O 2 was ≤80 Torr in four women (24%) but only during fast-R. In all subjects, Pa O 2 atV˙o 2 max was greater than the lower 95% prediction limit calculated from available data in men ( n = 72 C and 38 R) for both R and C. These data suggest intrinsic differences in gas exchange between R and C, due to differences in ventilation and also efficiency of gas exchange. The Pa O 2 responses to R and C exercise in our 17 subjects do not differ significantly from those previously observed in men.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jappl.2000.89.2.721

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Hopkins, S. R., Barker, R. C., Brutsaert, T. D., Gavin, T. P., Entin, P., Olfert, I. M., Veisel, S., & Wagner, P. D.
Venue
Journal of Applied Physiology
Published
2000-08-01
Volume
89
Issue
2
Pages
721-730
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1839003392
Cited by
110
References
0
FWCI
5.57
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.