NIRS-derived skeletal muscle oxidative capacity is correlated with aerobic fitness and independent of sex
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Near-infrared spectroscopy (NIRS) can be used to measure skeletal muscle oxidative capacity. Here, we demonstrated that NIRS-derived skeletal muscle oxidative capacity of the vastus lateralis was independent of sex, reliable across and within days, and correlated with maximal and submaximal indices of aerobic fitness, including maximal oxygen uptake, lactate threshold, and respiratory compensation point. These findings highlight the utility of NIRS for investigating skeletal muscle oxidative capacity in females and males.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A guideline of selecting and reporting intraclass correlation coefficients for reliability research
Koo, T. K., & Li, M. Y. (2016) · Journal of Chiropractic Medicine · doi:10.1016/j.jcm.2016.02.012 · Cited by 31,709
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Burgomaster, K. A., Howarth, K. R., Phillips, S. M., Rakobowchuk, M., MacDonald, M. J., McGee, S. L., & Gibala, M. J. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2007.142109 · Cited by 1,257
Biomarkers of mitochondrial content in skeletal muscle of healthy young human subjects
Larsen, S., Nielsen, J., Hansen, C. N., Nielsen, L. B., Wibrand, F., Stride, N., Schroder, H. D., Boushel, R., Helge, J. W., Dela, F., et al. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2012.230185 · Cited by 1,180
Basal metabolic rate studies in humans: measurement and development of new equations
Henry, C. (2005) · Public Health Nutrition · doi:10.1079/phn2005801 · Cited by 1,033
Measurement of substrate oxidation during exercise by means of gas exchange measurements
Jeukendrup, A. E., & Wallis, G. A. (2005) · International Journal of Sports Medicine · doi:10.1055/s-2004-830512 · Cited by 799
Jackson, A., Stanforth, P., Gagnon, J., Rankinen, T., Leon, A., Rao, D., Skinner, J., Bouchard, C., & Wilmore, J. (2002) · International Journal of Obesity · doi:10.1038/sj.ijo.0802006 · Cited by 694
Determinants of fat oxidation during exercise in healthy men and women: a cross-sectional study
Venables, M. C., Achten, J., & Jeukendrup, A. E. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00662.2003 · Cited by 503
Tarnopolsky, M. A., Rennie, C. D., Robertshaw, H. A., Fedak-Tarnopolsky, S. N., Devries, M. C., & Hamadeh, M. J. (2007) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00472.2006 · Cited by 457
Muscle respiratory capacity and fiber type as determinants of the lactate threshold
Ivy, J. L., Withers, R. T., Van Handel, P. J., Elger, D. H., & Costill, D. L. (1980) · Journal of Applied Physiology · doi:10.1152/jappl.1980.48.3.523 · Cited by 363
Sex differences in exercise metabolism and the role of 17-beta estradiol.
TARNOPOLSKY, M. A. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31816212ff · Cited by 354
Perry, C. G. R., Heigenhauser, G. J. F., Bonen, A., & Spriet, L. L. (2008) · Applied Physiology Nutrition and Metabolism · doi:10.1139/h08-097 · Cited by 309
McCully, K. K., Fielding, R. A., Evans, W. J., Leigh, J. S., & Posner, J. D. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.75.2.813 · Cited by 288
Jacobs, R. A., & Lundby, C. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01081.2012 · Cited by 222
Exercise Intensity Thresholds: Identifying the Boundaries of Sustainable Performance
KEIR, D. A., FONTANA, F. Y., ROBERTSON, T. C., MURIAS, J. M., PATERSON, D. H., KOWALCHUK, J. M., & POGLIAGHI, S. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000613 · Cited by 205
Ryan, T. E., Southern, W. M., Reynolds, M. A., & McCully, K. K. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00835.2013 · Cited by 192
Nordby, P., Saltin, B., & Helge, J. W. (2006) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2005.00480.x · Cited by 148
Montero, D., Madsen, K., Meinild‐Lundby, A., Edin, F., & Lundby, C. (2018) · Experimental Physiology · doi:10.1113/ep087007 · Cited by 105
Lanza, I. R., Bhagra, S., Nair, K. S., & Port, J. D. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22733 · Cited by 103
Southern, W. M., Ryan, T. E., Reynolds, M. A., & McCully, K. (2014) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2013-0347 · Cited by 80
Cited by
Women at Altitude: Sex-Related Physiological Responses to Exercise in Hypoxia
Raberin, A., Burtscher, J., Citherlet, T., Manferdelli, G., Krumm, B., Bourdillon, N., Antero, J., Rasica, L., Malatesta, D., Brocherie, F., et al. (2024) · Sports Medicine · doi:10.1007/s40279-023-01954-6 · Cited by 70
Keller, J. L., Traylor, M. K., Gray, S. M., Hill, E. C., & Weir, J. P. (2023) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00174.2023 · Cited by 44
Urianstad, T., Villanova, S., Odden, I., Hansen, J., Mølmen, K. S., Porcelli, S., Rønnestad, B. R., & Cardinale, D. A. (2024) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00469.2024 · Cited by 19
Koutlas, A., Smilios, I., Kokkinou, E. M., Myrkos, A., Kounoupis, A., Dipla, K., & Zafeiridis, A. (2024) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2022.2159309 · Cited by 18
“Recent studies highlighted the correlation between NIRS-derived muscle mitochondrial oxidative capacity and VO 2 max (Beever et al., 2020; Guzman et al., 2020; Lagerwaard et al., 2019, 2021), supporting the physiological relevance of NIRS measurements (Lagerwaard et al., 2019).”
BackgroundMethodResultInfluentialSendra-Pérez, C., Encarnación-Martínez, A., Oficial-Casado, F., Salvador-Palmer, R., & Priego-Quesada, J. I. (2023) · Physiological Measurement · doi:10.1088/1361-6579/ad1457 · Cited by 9
Metadata
- Authors
- Beever, A. T., Tripp, T. R., Zhang, J., & MacInnis, M. J.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2020-09-01
- Volume
- 129
- Issue
- 3
- Pages
- 558-568
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W3044376357
- Cited by
- 70
- References
- 20
- FWCI
- 6.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.