CoChat

Effects of stabilizing or increasing respiratory motor outputs on obstructive sleep apnea

Open access
Xie, Ailiang, Teodorescu, Mihaela, Pegelow, David F., Teodorescu, Mihai C., Gong, Yuansheng, Fedie, Jessica E., Dempsey, Jerome A. · 2013 · Journal of Applied Physiology
Cited by 75

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

To determine how the obstructive sleep apnea (OSA) patient's pathophysiological traits predict the success of the treatment aimed at stabilization or increase in respiratory motor outputs, we studied 26 newly diagnosed OSA patients [apnea-hypopnea index (AHI) 42 ± 5 events/h with 92% of apneas obstructive] who were treated with O 2 supplementation, an isocapnic rebreathing system in which CO 2 was added only during hyperpnea to prevent transient hypocapnia, and a continuous rebreathing system. We also measured each patient's controller gain below eupnea [change in minute volume/change in end-tidal Pco 2 (ΔV̇e/ΔPet CO 2 )], CO 2 reserve (eupnea-apnea threshold Pet CO 2 ), and plant gain (ΔPet CO 2 /ΔV̇e), as well as passive upper airway closing pressure (Pcrit). With isocapnic rebreathing, 14/26 reduced their AHI to 31 ± 6% of control ( P < 0.01) (responder); 12/26 did not show significant change (nonresponder). The responders vs. nonresponders had a greater controller gain (6.5 ± 1.7 vs. 2.1 ± 0.2 l·min −1 ·mmHg −1 , P < 0.01) and a smaller CO 2 reserve (1.9 ± 0.3 vs. 4.3 ± 0.4 mmHg, P < 0.01) with no differences in Pcrit (−0.1 ± 1.2 vs. 0.2 ± 0.9 cmH 2 O, P > 0.05). Hypercapnic rebreathing (+4.2 ± 1 mmHg Pet CO 2 ) reduced AHI to 15 ± 4% of control ( P < 0.001) in 17/21 subjects with a wide range of CO 2 reserve. Hyperoxia (SaO 2 ∼95–98%) reduced AHI to 36 ± 11% of control in 7/19 OSA patients tested. We concluded that stabilizing central respiratory motor output via prevention of transient hypocapnia prevents most OSA in selected patients with a high chemosensitivity and a collapsible upper airway, whereas increasing respiratory motor output via moderate hypercapnia eliminates OSA in most patients with a wider range of chemosensitivity and CO 2 reserve. Reducing chemosensitivity via hyperoxia had a limited and unpredictable effect on OSA.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00064.2013

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Xie, A., Teodorescu, M., Pegelow, D. F., Teodorescu, M. C., Gong, Y., Fedie, J. E., & Dempsey, J. A.
Venue
Journal of Applied Physiology
Published
2013-07-01
Volume
115
Issue
1
Pages
22-33
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W1999663394
Cited by
75
References
6
FWCI
6.12
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.