Automatic tracking of medial gastrocnemius fascicle length during human locomotion
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
During human locomotion lower extremity muscle-tendon units undergo cyclic length changes that were previously assumed to be representative of muscle fascicle length changes. Measurements in cats and humans have since revealed that muscle fascicle length changes can be uncoupled from those of the muscle-tendon unit. Ultrasonography is frequently used to estimate fascicle length changes during human locomotion. Fascicle length analysis requires time consuming manual methods that are prone to human error and experimenter bias. To bypass these limitations, we have developed an automatic fascicle tracking method based on the Lucas-Kanade optical flow algorithm with an affine optic flow extension. The aims of this study were to compare gastrocnemius fascicle length changes during locomotion using the automated and manual approaches and to determine the repeatability of the automated approach. Ultrasound was used to examine gastrocnemius fascicle lengths in eight participants walking at 4, 5, 6, and 7 km/h and jogging at 7 km/h on a treadmill. Ground reaction forces and three dimensional kinematics were recorded simultaneously. The level of agreement between methods and the repeatability of the automated method were quantified using the coefficient of multiple correlation (CMC). Regardless of speed, the level of agreement between methods was high, with overall CMC values of 0.90 ± 0.09 (95% CI: 0.86–0.95). Repeatability of the algorithm was also high, with an overall CMC of 0.88 ± 0.08 (95% CI: 0.79–0.96). The automated fascicle tracking method presented here is a robust, reliable, and time-efficient alternative to the manual analysis of muscle fascicle length during gait.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of lower extremity kinematics during level walking
Kadaba, M. P., Ramakrishnan, H. K., & Wootten, M. E. (1990) · Journal of Orthopaedic Research · doi:10.1002/jor.1100080310 · Cited by 3,216
Repeatability of gait data using a functional hip joint centre and a mean helical knee axis
Besier, T. F., Sturnieks, D. L., Alderson, J. A., & Lloyd, D. G. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00087-3 · Cited by 532
Cited by
Farris, D. J., & Lichtwark, G. A. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2016.02.016 · Cited by 236
Self-citationIn vivo behavior of the human soleus muscle with increasing walking and running speeds
Lai, A., Lichtwark, G. A., Schache, A. G., Lin, Y.-C., Brown, N. A. T., & Pandy, M. G. (2015) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00128.2015 · Cited by 199
Self-citationCunningham, R. J., & Loram, I. D. (2020) · Journal of The Royal Society Interface · doi:10.1098/rsif.2019.0715 · Cited by 36
Fully Automated Analysis of Muscle Architecture from B-Mode Ultrasound Images with DL_Track_US
Ritsche, P., Franchi, M. V., Faude, O., Finni, T., Seynnes, O., & Cronin, N. J. (2024) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2023.10.011 · Cited by 20
Self-citationChardon, M. K., Rymer, W. Z., & Suresh, N. L. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2299753 · Cited by 17
Metadata
- Authors
- Cronin, N. J., Carty, C. P., Barrett, R. S., & Lichtwark, G.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2011-11
- Volume
- 111
- Issue
- 5
- Pages
- 1491-1496
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2017217079
- Cited by
- 213
- References
- 2
- FWCI
- 7.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.