CoChat

Skeletal muscle V̇o2kinetics by the NIRS repeated occlusions method during the recovery from cycle ergometer exercise

Open access
Zuccarelli, Lucrezia, do Nascimento Salvador, Paulo Cesar, Del Torto, Alessio, Fiorentino, Riccardo, Grassi, Bruno · 2020 · Journal of Applied Physiology
Cited by 32

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Near-infrared spectroscopy (NIRS) has been utilized as a noninvasive method to evaluate skeletal muscle mitochondrial function in humans, by calculating muscle V̇o 2(V̇o 2 m) recovery (off-) kinetics following short light-intensity plantar flexion exercise. The aim of the present study was to determine V̇o 2 m off- kinetics following standard cycle ergometer exercise of different intensities. Fifteen young physically active healthy men performed an incremental exercise (INCR) up to exhaustion and two repetitions of constant work-rate (CWR) exercises at 80% of gas exchange threshold (GET; MODERATE) and at 40% of the difference between GET and peak pulmonary V̇o 2(V̇o 2 p; HEAVY). V̇o 2 p and vastus lateralis muscle fractional O 2 extraction by NIRS (Δ[deoxy(Hb+Mb)]) were recorded continuously. Transient arterial occlusions were carried out at rest and during the recovery for V̇o 2 m calculation. All subjects tolerated the repeated occlusions protocol without problems. The quality of the monoexponential fitting for V̇o 2 m off-kinetics analysis was excellent (0.93≤ r 2≤0.99). According to interclass correlation coefficient, the test-retest reliability was moderate to good. V̇o 2 m values at the onset of recovery were ~27, ~38, and ~35 times higher (in MODERATE, HEAVY, and INCR, respectively) than at rest. The time constants (τ) of V̇o 2 m off-kinetics were lower ( P < 0.001) following MODERATE (29.1 ± 6.8 s) vs. HEAVY (40.8 ± 10.9) or INCR (42.9 ± 10.9), suggesting an exercise intensity dependency of V̇o 2 m off-kinetics. Only following MODERATE the V̇o 2 m off-kinetics were faster than the V̇o 2 p off-kinetics. V̇o 2 m off-kinetics, determined noninvasively by the NIRS repeated occlusions technique, can be utilized as a functional evaluation tool of skeletal muscle oxidative metabolism also following conventional cycle ergometer exercise. NEW & NOTEWORTHY This is the first study in which muscle V̇o 2 recovery kinetics, determined noninvasively by near-infrared spectroscopy (NIRS) by utilizing the repeated occlusions method, was applied following standard cycle ergometer exercise of different intensities. The results demonstrate that muscle V̇o 2 recovery kinetics, determined noninvasively by the NIRS repeated occlusions technique, can be utilized as a functional evaluation tool of skeletal muscle oxidative metabolism also following conventional cycle ergometer exercise, overcoming significant limitations associated with the traditionally proposed protocol.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00580.2019

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

See all 32

Metadata

Authors
Zuccarelli, L., do Nascimento Salvador, P. C., Del Torto, A., Fiorentino, R., & Grassi, B.
Venue
Journal of Applied Physiology
Published
2020-03-01
Volume
128
Issue
3
Pages
534-544
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W3001119936
Cited by
32
References
11
FWCI
3.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Skeletal muscle V̇o2kinetics by the NIRS repeated occlusions method during the recovery from cycle ergometer exercise. https://app.cochat.ai/papers/10.1152/japplphysiol.00580.2019
The paper
Zuccarelli, L., do Nascimento Salvador, P. C., Del Torto, A., Fiorentino, R., & Grassi, B. (2020). Skeletal muscle V̇o2kinetics by the NIRS repeated occlusions method during the recovery from cycle ergometer exercise. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00580.2019

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.