Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 347

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Modified moving average analysis of T-wave alternans to predict ventricular fibrillation with high accuracy

Nearing, Bruce D., Verrier, Richard L.·2002·Journal of Applied Physiology

Abstract

T-wave alternans is a marker of cardiac electrical instability with the potential for arrhythmia risk stratification. The modified moving average method was developed to measure alternans in settings with artifacts, noise, and nonstationary data. Algorithms were developed and performance characteristics were validated with simulated electrocardiograms (ECGs). Experimental laboratory ECGs with dynamically changing alternans values were analyzed. Alternans values estimated by modified moving average analysis correlated strongly with input alternans values ( r 2 = 0.9999). Rapidly changing alternans levels and phase reversals did not perturb the measurement. When heart rate was increased from 60 to 180 beats/min, with T-wave alternans apex moving from 237 to 103 ms after the R wave, the measured alternans peak varied <5% from input value. Simulated 50- to 1,000-μV motion artifact spikes typical of treadmill ECGs produced inaccuracies <2%. Alternans values in experimental laboratory study using standard electrodes tracked vulnerability to myocardial ischemia-induced ventricular fibrillation with 100% sensitivity and specificity at a cut point of 0.75 mV. Modified moving average analysis is a robust method that precisely measures T-wave alternans in settings with artifacts, noise, and nonstationary data typical of clinical ECGs and yields an accurate estimate of risk for ventricular fibrillation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00592.2001

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 27 references

Cited by

See all 347

Metadata

Authors
Nearing, B. D., & Verrier, R. L.
Venue
Journal of Applied Physiology
Published
2002-02-01
Volume
92
Issue
2
Pages
541-549
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2081231690
Cited by
347
References
27
FWCI
5.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Modified moving average analysis of T-wave alternans to predict ventricular fibrillation with high accuracy. https://app.cochat.ai/papers/10.1152/japplphysiol.00592.2001
The paper
Nearing, B. D., & Verrier, R. L. (2002). Modified moving average analysis of T-wave alternans to predict ventricular fibrillation with high accuracy. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00592.2001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.