Keeping older individuals cool in hot and moderately humid conditions: wetted clothing with and without an electric fan
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The present study evaluated whether wearing a water-soaked t-shirt, with or without electric fan use, mitigates thermal and cardiovascular strain in older individuals exposed to hot and moderately humid conditions. Nine healthy older individuals (68 ± 4 yr; five women) completed three 120-min heat exposures (42.4 ± 0.2°C, 34.2 ± 0.9% relative humidity) on separate days while wearing a dry t-shirt (CON), a t-shirt soaked with 500 ml of tap water (WET), or a t-shirt soaked with 500 ml of tap water while facing an electric fan (2.4 ± 0.4 m/s; WET+FAN). Measurements included core and skin temperatures, evaporative mass losses, heart rate, and blood pressure. In the WET condition, elevations in core temperature were attenuated compared with DRY from 30 to 120 min and compared with WET+FAN from 30 to 90 min ( P < 0.05). Evaporative mass losses (inclusive of sweat and water losses from the shirt) were greatest in WET+FAN, followed by WET, and then DRY ( P < 0.01). Sweat losses were lowest in WET, followed by DRY, and then WET+FAN ( P < 0.01). Heart rate was lower only at 60 min in WET versus DRY ( P = 0.01). No differences in mean arterial pressure were observed ( P = 0.51). In conclusion, wearing a water-soaked t-shirt without, but not with, electric fan use is an effective heat management strategy to mitigate thermal strain and lower sweat losses in older individuals exposed to hot and moderately humid conditions. NEW & NOTEWORTHY In older individuals exposed to hot and moderately humid environments, electric fan use coupled with a water-soaked t-shirt exacerbates sweat losses without mitigating heat strain compared with a dry t-shirt. However, wearing a water-soaked t-shirt without fan use reduces sweat losses and attenuates heat strain compared with a dry t-shirt and a fan/water-soaked t-shirt combination. These findings suggest wearing a water-soaked t-shirt is an effective heat-management strategy for older individuals during heat waves when air conditioning is inaccessible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
More Intense, More Frequent, and Longer Lasting Heat Waves in the 21st Century
Meehl, G. A., & Tebaldi, C. (2004) · Science · doi:10.1126/science.1098704 · Cited by 4,322 · cited 2×
“As average global surface temperatures are projected to rise, and heat waves are expected to increase in frequency, duration, and intensity (24, 33), exposure to high levels of heat stress will occur with greater regularity.”
BackgroundEstimating economic damage from climate change in the United States
Hsiang, S., Kopp, R., Jina, A., Rising, J., Delgado, M., Mohan, S., Rasmussen, D. J., Muir-Wood, R., Wilson, P., Oppenheimer, M., et al. (2017) · Science · doi:10.1126/science.aal4369 · Cited by 1,239 · cited 1×
“For individuals using air conditioners, rising electricity demands associated with residential cooling will increase household energy costs, potentially making air conditioning unaffordable for lower- and fixed-income individuals (22, 31).”
BackgroundExcess mortality related to the August 2003 heat wave in France
Fouillet, A., Rey, G., Laurent, F., Pavillon, G., Bellec, S., Guihenneuc-Jouyaux, C., Clavel, J., Jougla, E., & Hémon, D. (2006) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-006-0089-4 · Cited by 1,023 · cited 4×
“Older individuals are particularly vulnerable to heat stress, evidenced by greater hospitalizations and mortality among individuals aged 60 yr during heat waves (2, 12, 21, 50, 60).”
BackgroundInfluentialContribution of air conditioning adoption to future energy use under global warming
Davis, L. W., & Gertler, P. J. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1423558112 · Cited by 632 · cited 1×
“Finally, the risk of power outages during periods of peak electricity demand or following extreme weather events threatens access to air conditioning when it would be most protective (8, 59).”
BackgroundInfluentialExcess hospital admissions during the July 1995 heat wave in Chicago
Semenza, J. (1999) · American Journal of Preventive Medicine · doi:10.1016/s0749-3797(99)00025-2 · Cited by 619
Gagnon, D., Jay, O., & Kenny, G. P. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2012.248823 · Cited by 221 · cited 1×
“This finding is explained by a greater evaporative requirement for heat balance associated with a higher rate of convective heat gain (16) and suggests that even without any detrimental effect on heat strain, the use of an electric fan in hot conditions will substantially increase the volume of fluid intake required t…”
BackgroundShould electric fans be used during a heat wave?
Jay, O., Cramer, M. N., Ravanelli, N. M., & Hodder, S. G. (2015) · Applied Ergonomics · doi:10.1016/j.apergo.2014.07.013 · Cited by 105 · cited 2×
“The lack of a difference in core temperature between WET FAN and DRY likely reflected offsetting elevations in convective heat gain and evaporative heat loss (25, 30, 46).”
BackgroundSelf-citationThe impact of heat waves on mortality in Northwest India
Nori-Sarma, A., Anderson, G. B., Rajiva, A., ShahAzhar, G., Gupta, P., Pednekar, M. S., Son, J.-Y., Peng, R. D., & Bell, M. L. (2019) · Environmental Research · doi:10.1016/j.envres.2019.108546 · Cited by 70
Heat balance when wearing protective clothing
(1999) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/43.5.289 · Cited by 1
Cited by
Romanello, M., Di Napoli, C., Drummond, P., Green, C., Kennard, H., Lampard, P., Scamman, D., Arnell, N., Ayeb-Karlsson, S., Ford, L. B., et al. (2022) · The Lancet · doi:10.1016/s0140-6736(22)01540-9 · Cited by 1,710
Extreme Weather and Climate Change: Population Health and Health System Implications
Ebi, K. L., Vanos, J., Baldwin, J. W., Bell, J. E., Hondula, D. M., Errett, N. A., Hayes, K., Reid, C. E., Saha, S., Spector, J., et al. (2021) · Annual Review of Public Health · doi:10.1146/annurev-publhealth-012420-105026 · Cited by 1,213
“These behaviors may include application of ice or ice towels, dousing skin, or saturating clothing with water with added ventilation (fans) (26).”
BackgroundJay, O., Capon, A., Berry, P., Broderick, C., de Dear, R., Havenith, G., Honda, Y., Kovats, R. S., Ma, W., Malik, A., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(21)01209-5 · Cited by 737
Brown, H. A., John, K., Elliott, J. D., Deshayes, T. A., Gagnon, D., Jay, O., Clark, B., & Périard, J. D. (2026) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00105.2026 · Cited by 2
Metadata
- Authors
- Cramer, M. N., Huang, M., Moralez, G., & Crandall, C. G.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2020-03-01
- Volume
- 128
- Issue
- 3
- Pages
- 604-611
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W3005202533
- Cited by
- 63
- References
- 10
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Keeping older individuals cool in hot and moderately humid conditions: wetted clothing with and without an electric fan. https://app.cochat.ai/papers/10.1152/japplphysiol.00786.2019
- The paper
- Cramer, M. N., Huang, M., Moralez, G., & Crandall, C. G. (2020). Keeping older individuals cool in hot and moderately humid conditions: wetted clothing with and without an electric fan. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00786.2019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.