Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 179

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Mechanical ventilation-induced oxidative stress in the diaphragm

Open access
Zergeroglu, Murat A., McKenzie, Michael J., Shanely, R. Andrew, Van Gammeren, Darin, DeRuisseau, Keith C., Powers, Scott K.·2003·Journal of Applied Physiology

Abstract

Prolonged mechanical ventilation (MV) results in oxidative damage in the diaphragm; however, it is unclear whether this MV-induced oxidative injury occurs rapidly or develops slowly over time. Furthermore, it is unknown whether both soluble (cytosolic) and insoluble (myofibrillar) proteins are equally susceptible to oxidation during MV. These experiments tested two hypotheses: 1) MV-induced oxidative injury in the diaphragm occurs within the first 6 h after the initiation of MV; and 2) MV is associated with oxidative modification of both soluble and insoluble proteins. Adult Sprague-Dawley rats were randomly divided into one of seven experimental groups: 1) control ( n = 8); 2) 3-h MV ( n = 8); 3) 6-h MV ( n = 6); 4) 18-h MV ( n = 8); 5) 3-h anesthesia-spontaneous breathing ( n = 8); 6) 6-h anesthesia-spontaneous breathing ( n = 6); and 7) 18-h anesthesia-spontaneous breathing ( n = 8). Markers of oxidative injury in the diaphragm included the measurement of reactive (protein) carbonyl derivatives (RCD) and total lipid hydroperoxides. Three hours of MV did not result in oxidative injury in the diaphragm. In contrast, both 6 and 18 h of MV promoted oxidative injury in the diaphragm, as indicated by increases in both protein RCD and lipid hydroperoxides. Electrophoretic separation of soluble and insoluble proteins indicated that the MV-induced accumulation of RCD was limited to insoluble proteins with molecular masses of ∼200, 120, 80, and 40 kDa. We conclude that MV results in a rapid onset of oxidative injury in the diaphragm and that insoluble proteins are primary targets of MV-induced protein oxidation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00824.2002

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 179

Metadata

Authors
Zergeroglu, M. A., McKenzie, M. J., Shanely, R. A., Van Gammeren, D., DeRuisseau, K. C., & Powers, S. K.
Venue
Journal of Applied Physiology
Published
2003-09
Volume
95
Issue
3
Pages
1116-1124
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2087751082
Cited by
179
References
1
FWCI
7.57
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanical ventilation-induced oxidative stress in the diaphragm. https://app.cochat.ai/papers/10.1152/japplphysiol.00824.2002
The paper
Zergeroglu, M. A., McKenzie, M. J., Shanely, R. A., Van Gammeren, D., DeRuisseau, K. C., & Powers, S. K. (2003). Mechanical ventilation-induced oxidative stress in the diaphragm. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00824.2002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.