Evaluation of bioimpedance spectroscopy for measurements of body water distribution in healthy women before, during, and after pregnancy
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Bioimpedance spectroscopy (BIS) is a technique of interest in the study of human pregnancy because it can assess extracellular (ECW), intracellular (ICW), and total body water (TBW) as ECW plus ICW. The technique requires appropriate resistivity coefficients and has not been sufficiently evaluated during the reproductive cycle. Therefore, in a methodological study, we estimated ECW, ICW, and TBW, by means of BIS, and compared the results with the corresponding estimates obtained by using reference methods. Furthermore, results obtained by means of population-specific resistivity coefficients were compared with results obtained by means of general resistivity coefficients. These comparisons were made before pregnancy, in gestational weeks 14 and 32, as well as 2 wk postpartum in 21 healthy women. The reference methods were isotope and bromide dilution. Average ICW, ECW, and TBW, estimated by means of BIS, were in agreement with reference data before pregnancy, in gestational week 14, and postpartum. The corresponding comparison in gestational week 32 showed good agreement for ICW, whereas estimates by means of BIS were significantly ( P < 0.001) lower than the corresponding reference values for ECW and TBW. Thus the BIS technique, which was based on a model developed for the nonpregnant body, estimated increases in ICW accurately, whereas increases in ECW and TBW tended to be underestimated. Estimates obtained by using population-specific and general resistivity coefficients were very similar. In conclusion, the results indicated that BIS is potentially useful for studies during pregnancy but that further work is needed before it can be generally applied in such studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Multifrequency bioelectrical impedance analysis in women with a normal and hypertensive pregnancy
Valensise, H., Andreoli, A., Lello, S., Magnani, F., Romanini, C., & De Lorenzo, A. (2000) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/72.3.780 · Cited by 61
Forsum, E., Forsberg, A. M., Nilsson, E., Bergström, J., & Hultman, E. (2000) · Annals of Nutrition and Metabolism · doi:10.1159/000012837 · Cited by 9
Self-citation
Cited by
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Abduljalil, K., Furness, P., Johnson, T. N., Rostami-Hodjegan, A., & Soltani, H. (2012) · Clinical Pharmacokinetics · doi:10.2165/11597440-000000000-00000 · Cited by 371
“Body composition can change as early as in the first trimester([35,37,52,319]) and ‘baseline’ measurements obtained at the postpartum period or early in pregnancy may not represent the pre-pregnancy composition.”
BackgroundContemporary methods of body composition measurement
Fosbøl, M. Ø., & Zerahn, B. (2015) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12152 · Cited by 279
Bioimpedance Spectroscopy for Clinical Assessment of Fluid Distribution and Body Cell Mass
Earthman, C., Traughber, D., Dobratz, J., & Howell, W. (2007) · Nutrition in Clinical Practice · doi:10.1177/0115426507022004389 · Cited by 209
Metadata
- Authors
- Lof, M., & Forsum, E.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2004-03
- Volume
- 96
- Issue
- 3
- Pages
- 967-973
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2133515302
- Cited by
- 66
- References
- 3
- FWCI
- 1.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of bioimpedance spectroscopy for measurements of body water distribution in healthy women before, during, and after pregnancy. https://app.cochat.ai/papers/10.1152/japplphysiol.00900.2003
- The paper
- Lof, M., & Forsum, E. (2004). Evaluation of bioimpedance spectroscopy for measurements of body water distribution in healthy women before, during, and after pregnancy. Journal of Applied Physiology. https://doi.org/10.1152/japplphysiol.00900.2003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.