Quantitative Analyses of Dynamic Strain Sensitivity in Human Skin Mechanoreceptors
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Microneurographical recordings from 24 slowly adapting (SA) and 16 fast adapting (FA) cutaneous mechanoreceptor afferents were obtained in the human radial nerve. Most of the afferents innervated the hairy skin on the back of the hand. The afferents' receptive fields were subjected to controlled strains in a ramp-and-hold fashion with strain velocities from 1 to 64% · s−1, i.e., strain velocities within most of the physiological range. For all unit types, the mean variation in response onset approached 1 ms for strain velocities >8% · s−1. Except at the highest strain velocities, the first spike in a typical SAIII unit was evoked at strains <0.5% and a typical SAII unit began to discharge at <1% skin strain. Skin strain velocity had a profound effect on the discharge rates of all classes of afferents. The “typical” peak discharge rate at the highest strain velocity studied was 50–95 imp/s−1 depending on unit type. Excellent fits were obtained for both SA and FA units when their responses to ramp stretches were modeled by simple power functions ( r 2 > 0.9 for 95% of the units). SAIII units grouped with SAII with respect to onset latency and onset variation but with SAI units with respect to dynamic strain sensitivity. Because both SA and FA skin afferents respond strongly, quickly, and accurately to skin strain changes, they all seem to be able to provide useful information about movement-related skin strain changes and therefore contribute to proprioception and kinesthesia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE STRUCTURE AND FUNCTION OF THE SLOWLY ADAPTING TYPE II MECHANORECEPTOR IN HAIRY SKIN
Chambers, M. R., Andres, K. H., Duering, M. V., & Iggo, A. (1972) · Quarterly Journal of Experimental Physiology and Cognate Medical Sciences · doi:10.1113/expphysiol.1972.sp002177 · Cited by 463
Johansson, R. S. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012411 · Cited by 430 · cited 1×
“…Vallbo 1970), it is difficult to differentiate FAI units with relatively large RFs and well demarcated borders from FAII units with relatively small RFs but obscure boundaries without a detailed mapping of the RFs (Johansson 1978) and analyses of vibration responses (e.g., Johansson et al. 1982).”
BackgroundFinger movement responses of cutaneous mechanoreceptors in the dorsal skin of the human hand
Edin, B. B., & Abbs, J. H. (1991) · Journal of Neurophysiology · doi:10.1152/jn.1991.65.3.657 · Cited by 358
Self-citationPhillips, J. R., & Johnson, K. O. (1981) · Journal of Neurophysiology · doi:10.1152/jn.1981.46.6.1204 · Cited by 268
Cutaneous afferents provide information about knee joint movements in humans
Edin, B. B. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.0289j.x · Cited by 267
Self-citationEdin, B., Essick, G., Trulsson, M., & Olsson, K. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-01-00830.1995 · Cited by 117
Self-citationHallin, R. G. (1990) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.53.9.736 · Cited by 62
Cited by
Proske, U., & Gandevia, S. C. (2012) · Physiological Reviews · doi:10.1152/physrev.00048.2011 · Cited by 2,223
Coding and use of tactile signals from the fingertips in object manipulation tasks
Johansson, R. S., & Flanagan, J. R. (2009) · Nature Reviews Neuroscience · doi:10.1038/nrn2621 · Cited by 2,063
Cutaneous Receptors Contribute to Kinesthesia at the Index Finger, Elbow, and Knee
Collins, D. F., Refshauge, K. M., Todd, G., & Gandevia, S. C. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00191.2005 · Cited by 416
Properties of Somatosensory Synaptic Integration in Cerebellar Granule Cells In Vivo
Jörntell, H., & Ekerot, C.-F. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.2939-06.2006 · Cited by 298
Neural Basis of Touch and Proprioception in Primate Cortex
Delhaye, B. P., Long, K. H., & Bensmaia, S. J. (2018) · Comprehensive Physiology · doi:10.1002/cphy.c170033 · Cited by 214
Metadata
- Authors
- Edin, B. B.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2004-12
- Volume
- 92
- Issue
- 6
- Pages
- 3233-3243
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2139380199
- Cited by
- 129
- References
- 7
- FWCI
- 1.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative Analyses of Dynamic Strain Sensitivity in Human Skin Mechanoreceptors. https://app.cochat.ai/papers/10.1152/jn.00628.2004
- The paper
- Edin, B. B. (2004). Quantitative Analyses of Dynamic Strain Sensitivity in Human Skin Mechanoreceptors. Journal of Neurophysiology. https://doi.org/10.1152/jn.00628.2004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.