Combined macro-/mesoporous microelectrode arrays for low-noise extracellular recording of neural networks
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Microelectrode arrays (MEAs) are appealing tools to probe large neural ensembles and build neural prostheses. Microelectronics microfabrication technologies now allow building high-density MEAs containing several hundreds of microelectrodes. However, several major problems become limiting factors when the size of the microelectrodes decreases. In particular, regarding recording of neural activity, the intrinsic noise level of a microelectrode dramatically increases when the size becomes small (typically below 20-μm diameter). Here, we propose to overcome this limitation using a template-based, single-scale meso- or two-scale macro-/mesoporous modification of the microelectrodes, combining the advantages of an overall small geometric surface and an active surface increased by several orders of magnitude. For this purpose, standard platinum MEAs were covered with a highly porous platinum overlayer obtained by lyotropic liquid crystal templating possibly in combination with a microsphere templating approach. These porous coatings were mechanically more robust than Pt-black coating and avoid potential toxicity issues. They had a highly increased active surface, resulting in a noise level ∼3 times smaller than that of conventional flat electrodes. This approach can thus be used to build highly dense arrays of small-size microelectrodes for sensitive neural signal detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carbon nanotube coating improves neuronal recordings
Keefer, E. W., Botterman, B. R., Romero, M. I., Rossi, A. F., & Gross, G. W. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.174 · Cited by 721 · cited 1×
“Alternatively, carbon nanotubes can be considered to increase the performance of microelectrodes (Keefer et al. 2008; Shoval et al. 2009; Su et al. 2010; Wang et al. 2006), but this strategy also suffers from limited mechanical stability and also raises concerns regarding long-term biocompatibility.”
BackgroundMaynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640 · cited 1×
“Likewise, in vivo devices also offer an increasing number of channels (Csicsvari et al. 2003; Maynard et al. 1997; Nicolelis et al. 1997; Yao et al. 2007) with improved action potential discrimination obtained with dense arrays of closely spaced microelectrodes.”
BackgroundMassively Parallel Recording of Unit and Local Field Potentials With Silicon-Based Electrodes
Csicsvari, J., Henze, D. A., Jamieson, B., Harris, K. D., Sirota, A., Barthó, P., Wise, K. D., & Buzsáki, G. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00116.2003 · Cited by 402
In Vitro and In Vivo Evaluation of PEDOT Microelectrodes for Neural Stimulation and Recording
Venkatraman, S., Hendricks, J., King, Z. A., Sereno, A. J., Richardson-Burns, S., Martin, D., & Carmena, J. M. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2109399 · Cited by 319 · cited 1×
“polymers showing promising performances for neural interfacing (Kang et al. 2011; Venkatraman et al. 2011).”
BackgroundImproved focalization of electrical microstimulation using microelectrode arrays: a modeling study
Joucla, S., & Yvert, B. (2009) · PLoS ONE · doi:10.1371/journal.pone.0004828 · Cited by 68 · cited 1×
“Moreover, focalization of stimulation can be achieved using a ground surface surrounding the electrodes of an array, with the highest performance when the impedance of the material of this surface is lowest (Joucla et al. 2012; Joucla and Yvert 2009).”
BackgroundSelf-citation
Cited by
Safety Assessment of Graphene-Based Materials: Focus on Human Health and the Environment
Fadeel, B., Bussy, C., Merino, S., Vázquez, E., Flahaut, E., Mouchet, F., Evariste, L., Gauthier, L., Koivisto, A. J., Vogel, U., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b04758 · Cited by 671
Graphene in the design and engineering of next‐generation neural interfaces
Kostarelos, K., Vincent, M., Hebert, C., & Garrido, J. A. (2017) · Advanced Materials · doi:10.1002/adma.201700909 · Cited by 206
Neural interfaces engineered via micro- and nanostructured coatings
Chen, N., Tian, L., Patil, A. C., Peng, S., Yang, I. H., Thakor, N. V., & Ramakrishna, S. (2017) · Nano Today · doi:10.1016/j.nantod.2017.04.007 · Cited by 74
Yin, P., Liu, Y., Xiao, L., & Zhang, C. (2021) · Polymers · doi:10.3390/polym13162834 · Cited by 42
“The release of toxic lead, an ingredient of the conventional electroplating electrolyte, may be responsible for this issue [70].”
Background
Metadata
- Authors
- Heim, M., Rousseau, L., Reculusa, S., Urbanova, V., Mazzocco, C., Joucla, S., Bouffier, L., Vytras, K., Bartlett, P., Kuhn, A., & Yvert, B.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 2012-09-15
- Volume
- 108
- Issue
- 6
- Pages
- 1793-1803
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2063292353
- Cited by
- 60
- References
- 5
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.