Human cortical potentials evoked by stimulation of the median nerve. II. Cytoarchitectonic areas generating short-latency activity
The DOI matches its Crossref record.
Abstract
1. The anatomic generators of human median nerve somatosensory evoked potentials (SEPs) in the 40 to 250-ms latency range were investigated in 54 patients by means of cortical-surface and transcortical recordings obtained during neurosurgery. 2. Contralateral stimulation evoked three groups of SEPs recorded from the hand representation area of sensorimotor cortex: P45-N80-P180, recorded anterior to the central sulcus (CS) and maximal on the precentral gyrus; N45-P80-N180, recorded posterior to the CS and maximal on the postcentral gyrus; and P50-N90-P190, recorded near and on either side of the CS. 3. P45-N80-P180 inverted in polarity to N45-P80-N180 across the CS but was similar in polarity from the cortical surface and white matter in transcortical recordings. These spatial distributions were similar to those of the short-latency P20-N30 and N20-P30 potentials described in the preceding paper, suggesting that these long-latency potentials are generated in area 3b of somatosensory cortex. 4. P50-N90-P190 was largest over the anterior one-half of somatosensory cortex and did not show polarity inversion across the CS. This spatial distribution was similar to that of the short-latency P25-N35 potentials described in the preceding paper and, together with our and Goldring et al. 1970; Stohr and Goldring 1969 transcortical recordings, suggest that these long-latency potentials are generated in area 1 of somatosensory cortex. 5. SEPs of apparently local origin were recorded from several regions of sensorimotor cortex to stimulation of the ipsilateral median nerve. Surface and transcortical recordings suggest that the ipsilateral potentials are generated not in area 3b, but rather in other regions of sensorimotor cortex perhaps including areas 4, 1, 2, and 7. This spatial distribution suggests that the ipsilateral potentials are generated by transcallosal input from the contralateral hemisphere. 6. Recordings from the periSylvian region were characterized by P100 and N100, recorded above and below the Sylvian sulcus (SS) respectively. This distribution suggests a tangential generator located in the upper wall of the SS in the second somatosensory area (SII). In addition, N125 and P200, recorded near and on either side of the SS, suggest a radial generator in a portion of SII located in surface cortex above the SS. 7. In comparison with the short-latency SEPs described in the preceding paper, the long-latency potentials were more variable and were more affected by intraoperative conditions.(ABSTRACT TRUNCATED AT 400 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Transcranial focused ultrasound modulates the activity of primary somatosensory cortex in humans
Legon, W., Sato, T. F., Opitz, A., Mueller, J., Barbour, A., Williams, A., & Tyler, W. J. (2014) · Nature Neuroscience · doi:10.1038/nn.3620 · Cited by 981
Allison, T. (1999) · Cerebral Cortex · doi:10.1093/cercor/9.5.415 · Cited by 882
Self-citationDistributed processing of pain and vibration by the human brain
Coghill, R., Talbot, J., Evans, A., Meyer, E., Gjedde, A., Bushnell, M., & Duncan, G. (1994) · The Journal of Neuroscience · doi:10.1523/jneurosci.14-07-04095.1994 · Cited by 808
Recommendations for the clinical use of somatosensory-evoked potentials
Cruccu, G., Aminoff, M. J., Curio, G., Guerit, J. M., Kakigi, R., Mauguiere, F., Rossini, P. M., Treede, R.-D., & Garcia-Larrea, L. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.03.016 · Cited by 694
A Temporally Asymmetric Hebbian Rule Governing Plasticity in the Human Motor Cortex
Wolters, A., Sandbrink, F., Schlottmann, A., Kunesch, E., Stefan, K., Cohen, L. G., Benecke, R., & Classen, J. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00900.2002 · Cited by 586
Brain generators of laser-evoked potentials: from dipoles to functional significance
Garcia-Larrea, L., Frot, M., & Valeriani, M. (2003) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2003.10.008 · Cited by 541
Duffau, H., Capelle, L., Denvil, D., Sichez, N., Gatignol, P., Taillandier, L., Lopes, M., Mitchell, M.-C., Roche, S., Muller, J.-C., et al. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.4.0764 · Cited by 539
Interactions between inhibitory and excitatory circuits in the human motor cortex
Chen, R. (2004) · Experimental Brain Research · doi:10.1007/s00221-003-1684-1 · Cited by 452
Image-Guided Transcranial Focused Ultrasound Stimulates Human Primary Somatosensory Cortex
Lee, W., Kim, H., Jung, Y., Song, I.-U., Chung, Y. A., & Yoo, S.-S. (2015) · Scientific Reports · doi:10.1038/srep08743 · Cited by 414
Nguyen, J.-P., Lefaucheur, J.-P., Decq, P., Uchiyama, T., Carpentier, A., Fontaine, D., Brugières, P., Pollin, B., Fève, A., Rostaing, S., et al. (1999) · Pain · doi:10.1016/s0304-3959(99)00062-7 · Cited by 390
Oxley, T. J., Opie, N. L., John, S. E., Rind, G. S., Ronayne, S. M., Wheeler, T. L., Judy, J. W., McDonald, A. J., Dornom, A., Lovell, T. J. H., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3428 · Cited by 339
Magnetoencephalography in the study of human somatosensory cortical processing
Hari, R., & Forss, N. (1999) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1999.0470 · Cited by 338
Somatosensory Homunculus as Drawn by MEG
Nakamura, A., Yamada, T., Goto, A., Kato, T., Ito, K., Abe, Y., Kachi, T., & Kakigi, R. (1998) · NeuroImage · doi:10.1006/nimg.1998.0332 · Cited by 338
Neuromodulation with single‐element transcranial focused ultrasound in human thalamus
Legon, W., Ai, L., Bansal, P., & Mueller, J. K. (2018) · Human Brain Mapping · doi:10.1002/hbm.23981 · Cited by 334
Intracranial EEG and human brain mapping
Lachaux, J. P., Rudrauf, D., & Kahane, P. (2003) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2004.01.018 · Cited by 331
Alarcon, G., Guy, C. N., Binnie, C. D., Walker, S. R., Elwes, R. D., & Polkey, C. E. (1994) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.57.4.435 · Cited by 319
Puce, A., Constable, R. T., Luby, M. L., McCarthy, G., Nobre, A. C., Spencer, D. D., Gore, J. C., & Allison, T. (1995) · Journal of Neurosurgery · doi:10.3171/jns.1995.83.2.0262 · Cited by 312
Self-citationParallel Activation of Primary and Secondary Somatosensory Cortices in Human Pain Processing
Ploner, M., Schmitz, F., Freund, H.-J., & Schnitzler, A. (1999) · Journal of Neurophysiology · doi:10.1152/jn.1999.81.6.3100 · Cited by 283
Allison, T., McCarthy, G., & Wood, C. C. (1992) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(92)90082-m · Cited by 278
Self-citationActivation of the human posterior parietal cortex by median nerve stimulation
Forss, N., Hari, R., Salmelin, R., Ahonen, A., H�m�l�inen, M., Kajola, M., Knuutila, J., & Simola, J. (1994) · Experimental Brain Research · doi:10.1007/bf00239597 · Cited by 269
Mauguière, F., Merlet, I., Forss, N., Vanni, S., Jousmäki, V, Adeleine, P., & Hari, R. (1997) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/s0013-4694(97)00006-0 · Cited by 256
Anterior and posterior association cortex contributions to the somatosensory P300
Yamaguchi, S., & Knight, R. (1991) · The Journal of Neuroscience · doi:10.1523/jneurosci.11-07-02039.1991 · Cited by 254
High resolution EEG: 124-channel recording, spatial deblurring and MRI integration methods
Gevins, A., Le, J., Martin, N. K., Brickett, P., Desmond, J., & Reutter, B. (1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90050-7 · Cited by 246
“The maximum and minimum deblurred potentials are situated on either side of the central sulcus, which is consistent with a tangential generator situated within the posterior bank of the central sulcus (Allison 1987; Allison et al. 1989a,b).”
Transient Suppression of Ipsilateral Primary Somatosensory Cortex during Tactile Finger Stimulation
Hlushchuk, Y., & Hari, R. (2006) · The Journal of Neuroscience · doi:10.1523/jneurosci.5536-05.2006 · Cited by 244
fMRI of the Responses to Vibratory Stimulation of Digit Tips
Francis, S. T., Kelly, E. F., Bowtell, R., Dunseath, W. J. R., Folger, S. E., & McGlone, F. (2000) · NeuroImage · doi:10.1006/nimg.2000.0541 · Cited by 242
A distributed spatio-temporal EEG/MEG inverse solver
Ou, W., Hämäläinen, M. S., & Golland, P. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.05.063 · Cited by 219
“In particular, MNE is not appropriate for localization of early sensory activations and focal epilepsy, which have been shown to be focal in intracranial experiments (Barth et al., 1982; Allison et al., 1989).”
Wikström, H., Huttunen, J., Korvenoja, A., Virtanen, J., Salonen, O., Aronen, H., & Ilmoniemi, R. J. (1996) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/s0168-5597(96)95688-9 · Cited by 213
Fingertip Representation in the Human Somatosensory Cortex: An fMRI Study
Gelnar, P. A., Krauss, B. R., Szeverenyi, N. M., & Apkarian, A. V. (1998) · NeuroImage · doi:10.1006/nimg.1998.0341 · Cited by 190
“The primary somatosensory cortex of each subject was divided into subregions in a manner similar to that performed by Allison et al. (1989a), which was based upon studies in humans and Old World monkeys (Powell and Mountcastle, 1959; Vogt, 1928), and in reference to the Talairach–Tournoux atlas…”
BackgroundMethodResultMatsunaga, K., Nitsche, M. A., Tsuji, S., & Rothwell, J. C. (2004) · Clinical Neurophysiology · doi:10.1016/s1388-2457(03)00362-6 · Cited by 187
Neuromagnetic evidence of pre- and post-central cortical sources of somatosensory evoked responses
Kawamura, T., Nakasato, N., Seki, K., Kanno, A., Fujita, S., Fujiwara, S., & Yoshimoto, T. (1996) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(95)00217-0 · Cited by 178
Neural generators of early cortical somatosensory evoked potentials in the awake monkey
Peterson, N. N., Schroeder, C. E., & Arezzo, J. C. (1995) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(95)00006-e · Cited by 164
Massimini, M., Rosanova, M., & Mariotti, M. (2003) · Journal of Neurophysiology · doi:10.1152/jn.00373.2002 · Cited by 124
Heartbeat and somatosensory perception
Al, E., Iliopoulos, F., Nikulin, V. V., & Villringer, A. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118247 · Cited by 86
Vision of the body modulates processing in primary somatosensory cortex
Longo, M. R., Pernigo, S., & Haggard, P. (2011) · Neuroscience Letters · doi:10.1016/j.neulet.2010.12.007 · Cited by 57
Dubois, J., Adibpour, P., Poupon, C., Hertz-Pannier, L., & Dehaene-Lambertz, G. (2016) · Brain Plasticity · doi:10.3233/bpl-160031 · Cited by 40
“In the adult brain, a negative peak (N20) and a positive peak (P25) are measured over centro-parietal electrodes at around 20 and 25 ms [132], and are supposed to reflect activity in the primary somatosensory cortex (S1) [133].”
BackgroundDel Vecchio, M., Caruana, F., Sartori, I., Pelliccia, V., Lo Russo, G., Rizzolatti, G., & Avanzini, P. (2019) · Brain Structure and Function · doi:10.1007/s00429-018-1754-6 · Cited by 23
Metadata
- Authors
- Allison, T., McCarthy, G., Wood, C. C., Darcey, T. M., Spencer, D. D., & Williamson, P. D.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1989-09-01
- Volume
- 62
- Issue
- 3
- Pages
- 694-710
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W1944054422
- Cited by
- 566
- References
- 0
- FWCI
- 15.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.