Cat hindlimb muscles exert substantial torques outside the sagittal plane
The DOI matches its Crossref record.
Abstract
1. We studied the contributions of several hindlimb muscles to ankle torque in adult cats deeply anesthetized with pentobarbital sodium. Isometric torques were measured with a multiaxis, force-moment sensor connected to the plantar surface of the foot. 2. Individual muscle torques were provoked by using a combination of muscle nerve stimulation and selective denervations and tenotomies. Torques were represented by three orthogonal components; defined as dorsiflexion/plantarflexion, inversion/eversion (rotation about the long axis of the foot), and toe-in/toe-out (rotation about the axis of the tibia). 3. Most of the muscles tested exerted substantial torques about more than one of the orthogonal axes, each of which shared a common origin centered midway between the medial and lateral malleoli. The lateral and especially the medial head of the gastrocnemius muscle exhibited large toe-out torques and eversion torques as well as the classical plantarflexion components. 4. The torque exerted by tibialis anterior was seen to oppose that of both medial and lateral gastrocnemius in each of the three directions. The toe-in and inversion torques exerted by tibialis posterior was opposed in these directions by both peroneus brevis and peroneus longus. Flexor hallucis longus exerted approximately 10 times more plantarflexion torque than did flexor digitorum longus; therefore, these two muscles cannot be considered pure synergists. 5. The major plantarflexors and dorsiflexor of the cat ankle joint contribute substantial torques outside the sagittal plane. Their opposing torques lead to increased joint stiffness; the net effect of coactivation of these muscles causes ground reaction forces oriented so as to maintain stability during quadrupedal stance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Load-Regulating Mechanisms in Gait and Posture: Comparative Aspects
Duysens, J., Clarac, F., & Cruse, H. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.1.83 · Cited by 551
Neural Control of Stereotypic Limb Movements
Rossignol, S. (1996) · Comprehensive Physiology · doi:10.1002/cphy.cp120105 · Cited by 385
Muscle proprioceptive feedback and spinal networks
Windhorst, U. (2007) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2007.03.010 · Cited by 324
EMG Responses to Maintain Stance During Multidirectional Surface Translations
Henry, S. M., Fung, J., & Horak, F. B. (1998) · Journal of Neurophysiology · doi:10.1152/jn.1998.80.4.1939 · Cited by 290
Prilutsky, B. L. (2000) · Motor Control · doi:10.1123/mcj.4.1.1 · Cited by 233
Compartmentalization of Muscles and Their Motor Nuclei: The Partitioning Hypothesis
English, A. W., Wolf, S. L., & Segal, R. L. (1993) · Physical Therapy · doi:10.1093/ptj/73.12.857 · Cited by 194
Self-citationBurke, R. E., Degtyarenko, A. M., & Simon, E. S. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.86.1.447 · Cited by 167
“This is quite different from the activity in FDL’s close, albeit not exact, mechanical synergist flexor hallucis longus (FHL) (see Lawrence et al. 1993; Young et al. 1993), which is active throughout the stance phase of st pping and becomes silent just before FDL bursts.”
BackgroundON THE ROLE OF RECURRENT INHIBITORY FEEDBACK IN MOTOR CONTROL
WINDHORST, U. (1996) · Progress in Neurobiology · doi:10.1016/0301-0082(96)00023-8 · Cited by 166
Quantification of recruitment properties of multiple contact cuff electrodes
Grill, W. M., & Mortimer, J. T. (1996) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.506402 · Cited by 136
Tarler, M. D., & Mortimer, J. T. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.828415 · Cited by 110
A slowly penetrating interfascicular nerve electrode for selective activation of peripheral nerves
Tyler, D. J., & Durand, D. M. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559349 · Cited by 108
Grill, W. M., & Mortimer, J. T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736150 · Cited by 103
“O curves from eight measurements sessions in four different animals).”
BackgroundChronic Measurement of the Stimulation Selectivity of the Flat Interface Nerve Electrode
Leventhal, D. K., & Durand, D. M. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827535 · Cited by 55
“Based on results from acute experiments [10], [11], [22], the trajectories can be categorized as activating (starting from the bottom and going clockwise) the CP nerve, the nerve to the medial gastrocnemius muscle (MG), the nerve to the lateral gastrocnemius and soleus muscles (LG), and the Tib.”
Stieglitz, T., Schuettler, M., Schneider, A., Valderrama, E., & Navarro, X. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.819793 · Cited by 19
Metadata
- Authors
- Lawrence, J. H., Nichols, T. R., & English, A. W.
- Venue
- Journal of Neurophysiology
- Publisher
- American Physiological Society
- Published
- 1993-01-01
- Volume
- 69
- Issue
- 1
- Pages
- 282-285
- ISSN
- 0022-3077 (ISSN-L)
- 1522-1598
- OpenAlex
- W2101531732
- Cited by
- 99
- References
- 0
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.