CoChat

Comparison of evoked potentials and high-frequency (gamma-band) oscillating potentials in rat auditory cortex

Franowicz, M. N., Barth, D. S. · 1995 · Journal of Neurophysiology
Cited by 109

The DOI matches its Crossref record.

Abstract

1. Transient and steady-state (40 Hz) evoked potentials, as well as spontaneous and click-evoked gamma-band oscillations, were recorded from 15 lightly anesthetized rats using an 8 x 8 electrode epipial array covering auditory cortex and adjacent areas to determine and compare the spatiotemporal distributions of these four phenomena. 2. The transient evoked response replicated earlier findings in our laboratory, consisting of an initial biphasic sharp wave in area 41, a similar but delayed biphasic sharp wave in area 36, and more widely distributed slow-wave components. Spatiotemporal analysis supported a model of parallel and asynchronous activation of distinct groups of thalamocortical projections underlying the neurogenesis of these temporal components of the middle-latency auditory evoked potential (MAEP) complex. 3. The 40-Hz response to click trains was superimposed on a steady potential shift (SP), both of which were localized within primary auditory cortex. Epipial distributions of the SP were similar to those of the shortest-latency negative peak in area 41 recorded in the same animals, suggesting similar neural generators. The 40-Hz response was more focal and dissimilar from the SP and any other temporal components of the MAEP complex, suggesting that a unique subpopulation of cells underlies its neurogenesis. 4. Spontaneous gamma-band activity, as assessed by power spectrum analysis, was localized to primary and secondary auditory cortex but had a variable distribution between rats that did not conform to the cytoarchitectonic boundaries within subdivisions of this region. Digital movies computed for individual bursts of gamma-activity indicated a high degree of spatiotemporal variability within and between bursts. 5. Single-trial spectral analysis of click responses indicated an inhibition of gamma-band oscillations during most of the MAEP complex, with subsequent enhanced gamma-activity during the 300- to 350-ms slow-wave component that outlasted the MAEP by approximately 500 ms. The epipial distributions of prestimulus and enhanced poststimulus gamma-oscillations were the same. In contrast to the 40-Hz response to click trains, phase-locking of gamma-oscillations by the single click stimulus was not observed. 6. These results suggest that both the MAEP complex and the steady-state 40-Hz response with its associated SP are highly stereotyped in lightly anesthetized rodent cortex. Their spatiotemporal distributions are probably determined in large part by asynchronous activation of parallel thalamocortical projection systems. Our data suggest no direct link between either the MAEP or the steady-state 40-Hz response to spontaneous or evoked gamma-band oscillations in auditory cortex.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1995.74.1.96

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Franowicz, M. N., & Barth, D. S.
Venue
Journal of Neurophysiology
Published
1995-07-01
Volume
74
Issue
1
Pages
96-112
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2414474761
Cited by
109
References
0
FWCI
2.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.