Probabilistic modeling of selective stimulation of the human sciatic nerve with a flat interface nerve electrode
Open accessThe DOI matches its Crossref record; 75 of the 76 references it cites were found in a registry or an index.
Abstract
Ankle control is critical to both standing balance and efficient walking. The hypothesis presented in this paper is that a Flat Interface Nerve Electrode (FINE) placed around the sciatic nerve with a fixed number of contacts at predetermined locations and without a priori knowledge of the nerve's underlying neuroanatomy can selectively control each ankle motion. Models of the human sciatic nerve surrounded by a FINE of varying size were created and used to calculate the probability of selective activation of axons within any arbitrarily designated, contiguous group of fascicles. Simulations support the hypothesis and suggest that currently available implantable technology cannot selectively recruit each target plantar flexor individually but can restore plantar flexion or dorsiflexion from a site on the sciatic nerve without spillover to antagonists. Successful activation of individual ankle muscles in 90% of the population can be achieved by utilizing bipolar stimulation and/or by using a cuff with at least 20 contacts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“Nerve electrodes activate populations of axons on the basis of size and location relative to the stimulating contact (23).”
From A neural interface provides long-term stable natural touch perception (2014) · cites this paper as [23]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biomechanics and motor control of human movement
(1990) · Choice Reviews Online · doi:10.5860/choice.28-2135 · Cited by 8,451
Biomechanics and Motor Control of Human Movement
Winter, D. A. (2009) · Wiley eBooks · doi:10.1002/9780470549148 · Cited by 6,066
OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement
Delp, S. L., Anderson, F. C., Arnold, A. S., Loan, P., Habib, A., John, C. T., Guendelman, E., & Thelen, D. G. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.901024 · Cited by 4,933
Electroencephalography and clinical neurophysiology
(1994) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(94)90118-x · Cited by 1,759
The Journal of Rehabilitation Research and Development
(2025) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.0000.00.0000 · Cited by 1,566
(2013) · Experimental Brain Research · doi:10.1007/221.1432-1106 · Cited by 1,096
McIntyre, C. C., Richardson, A. G., & Grill, W. M. (2002) · Journal of Neurophysiology · doi:10.1152/jn.00353.2001 · Cited by 761
Are Current Measurements of Lower Extremity Muscle Architecture Accurate?
Ward, S. R., Eng, C. M., Smallwood, L. H., & Lieber, R. L. (2009) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-008-0594-8 · Cited by 693
A transverse intrafascicular multichannel electrode (TIME) to interface with the peripheral nerve
Boretius, T., Badia, J., Pascual-Font, A., Schuettler, M., Navarro, X., Yoshida, K., & Stieglitz, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.05.010 · Cited by 468 · cited 1×
“Similar results have been found with intrafascicular electrodes (Badia et al. 2011; Boretius et al. 2010; Nannini and Horch 1991; Yoshida and Horch 1993).”
Functionally selective peripheral nerve stimulation with a flat interface nerve electrode
Tyler, D. J., & Durand, D. M. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806840 · Cited by 398 · cited 1×
“Other animal experiments have shown that the FINE can selectively restore individual functions controlled by the SN (Leventhal and Durand 2003; Tarler and Mortimer 2003; Tyler and Durand 2002).”
Self-citation
Research works printed but not linked: 4
- Acosta AM 2002 Dissertation on Musculoskeletal modeling of the shoulder and elbow in cervical spinal cord injury Case Western Reserve University Cleveland
- Boyd IA 1968 The structure and innervation of mammalian muscle spindles Electroencephalogr Clin Neurophysiol 25 4 406 4176596
- CDC 2007 Morbidity and Mortality Weekly Report 56 19 469 474 17510610
- Polasek K 2007 Clincial implementation of nerve cuff electrodes for an upper extremity neuroprosthesis Dissertation Case Western Reserve University Cleveland
Cited by
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Self-citationTan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., & Tyler, D. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/2/026002 · Cited by 175
Self-citationA review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Neural interfaces for somatosensory feedback: bringing life to a prosthesis
Tyler, D. J. (2015) · Current Opinion in Neurology · doi:10.1097/wco.0000000000000266 · Cited by 105
Self-citationRaspopovic, S., Petrini, F. M., Zelechowski, M., & Valle, G. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2600560 · Cited by 84
Metadata
- Authors
- Schiefer, M. A., Tyler, D. J., & Triolo, R. J.
- Affiliations
- Case Western Reserve University (US)
- Louis Stokes Cleveland VA Medical Center (US)
- Corresponding author
- Schiefer, Matthew A.
- Venue
- Journal of Computational Neuroscience
- Published
- 2012-01-06
- Volume
- 33
- Issue
- 1
- Pages
- 179-190
- ISSN
- 0929-5313 (ISSN-L)
- 1573-6873
- PMC
- PMC3357453
- OpenAlex
- W2008965098
- Cited by
- 53
- References
- 76
- Citations by year
- 2026: 3 · 2025: 5 · 2024: 4 · 2023: 5 · 2022: 3 · 2021: 3 · 2020: 4 · 2019: 4 · 2018: 5 · 2017: 4 · 2016: 2 · 2015: 5 · 2014: 2 · 2013: 4
- FWCI
- 1.45
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Journal of Computational Neuroscience (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- U.S. Department of Veterans Affairs (I01-RX001039)
- National Institute of Arthritis and Musculoskeletal and Skin Diseases (T32AR007505)
- National Institute of Biomedical Imaging and Bioengineering (R01EB001889)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Keywords
- sciatic nerve, selective nerve stimulation, ankle control, plantar flexion, dorsiflexion, nerve fascicles, bipolar stimulation, cuff electrodes, ankle prosthesis, neuromodulation, standing balance
- MeSH terms
- Ankle Joint, Axons, Biophysics, Electric Stimulation, Electrodes, Electrodes, Implanted, Humans, Models, Theoretical, Movement, Probability, Recruitment, Neurophysiological, Sciatic Nerve
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Probabilistic modeling of selective stimulation of the human sciatic nerve with a flat interface nerve electrode. https://app.cochat.ai/papers/10.1007/s10827-011-0381-5
- The paper
- Schiefer, M. A., Tyler, D. J., & Triolo, R. J. (2012). Probabilistic modeling of selective stimulation of the human sciatic nerve with a flat interface nerve electrode. Journal of Computational Neuroscience. https://doi.org/10.1007/s10827-011-0381-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.