Abstract

Kay, Alan R., Mutsuyuki Sugimori, and Rodolfo Llinás. Kinetic and stochastic properties of a persistent sodium current in mature guinea pig cerebellar Purkinje cells. J. Neurophysiol. 80: 1167–1179, 1998. Whole cell voltage-clamp techniques were employed to characterize the sodium (Na) conductances in acutely dissociated, mature guinea-pig cerebellar Purkinje cells. Three phenomenological components were noted: two inactivating and a persistent component ( I P Na). All exhibited similar sensitivities to tetrodotoxin (TTX; IC 50 ∼3 nM). The inactivating Na current demonstrates two components with different rates of inactivation. The persistent component activates at a more negative membrane potential than the inactivating components and shows little inactivation during a 5-s pulse. The amplitude of the persistent Na conductance had a higher Q 10 than the inactivating Na conductance (2.7 vs. 1.3). I P Na rapidly activates (∼1 ms) and deactivates (<0.2 ms) and like the fast component appears to be exclusively Na permeable. I P Na is not a “window” current because its range of activation exceeds the small overlap between the steady-state activation and inactivation characteristics of the inactivating current. Anomalous tail currents were observed during voltage pulses above –40 mV after a prepulse above –30 mV. The tails rose to a maximum inward current with a time constant of 1.5 ms and decayed to a persistent inward current with a time constant of 20 ms. The tails probably arose as a result of recovery from inactivation through the open state. The noise characteristics of I P Na were anomalous in that the measured variance was lower at threshold voltages than would be predicted by a binomial model. The form of the variance could be partially accounted for by postulating that the maximum probability of activation of the persistent current was less than unity. The noise characteristics of I P Na are such as to minimize noise near spike activation threshold and sharpen the threshold.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/jn.1998.80.3.1167

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Kay, A. R., Sugimori, M., & Llinás, R.
Venue
Journal of Neurophysiology
Published
1998-09-01
Volume
80
Issue
3
Pages
1167-1179
ISSN
  • 0022-3077 (ISSN-L)
  • 1522-1598
OpenAlex
W2258435584
Cited by
140
References
3
FWCI
1.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.