The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Automatic Seizure Detection Based on Time-Frequency Analysis and Artificial Neural Networks
Open accessAbstract
The recording of seizures is of primary interest in the evaluation of epileptic patients. Seizure is the phenomenon of rhythmicity discharge from either a local area or the whole brain and the individual behavior usually lasts from seconds to minutes. Since seizures, in general, occur infrequently and unpredictably, automatic detection of seizures during long-term electroencephalograph (EEG) recordings is highly recommended. As EEG signals are nonstationary, the conventional methods of frequency analysis are not successful for diagnostic purposes. This paper presents a method of analysis of EEG signals, which is based on time-frequency analysis. Initially, selected segments of the EEG signals are analyzed using time-frequency methods and several features are extracted for each segment, representing the energy distribution in the time-frequency plane. Then, those features are used as an input in an artificial neural network (ANN), which provides the final classification of the EEG segments concerning the existence of seizures or not. We used a publicly available dataset in order to evaluate our method and the evaluation results are very promising indicating overall accuracy from 97.72% to 100%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural networks for pattern recognition
(1994) · Choice Reviews Online · doi:10.5860/choice.31-5500 · Cited by 18,538
The ten-twenty electrode system of the international federation
Jasper, H. H. (1958) · Electroencephalography and Clinical Neurophysiology · Cited by 6,567
Andrzejak, R. G., Lehnertz, K., Mormann, F., Rieke, C., David, P., & Elger, C. E. (2001) · Physical Review E · doi:10.1103/physreve.64.061907 · Cited by 3,032
Klem, G. H., Lüders, H. O., Jasper, H. H., & Elger, C. E. (1999) · PubMed · Cited by 2,361
EEG signal classification using wavelet feature extraction and a mixture of expert model.
SUBASI, A. (2007) · Expert Systems with Applications · doi:10.1016/j.eswa.2006.02.005 · Cited by 1,182
Analysis of EEG records in an epileptic patient using wavelet transform
Adeli, H., Zhou, Z., & Dadmehr, N. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(02)00340-0 · Cited by 1,154
Seizure prediction: the long and winding road
Mormann, F., Andrzejak, R. G., Elger, C. E., & Lehnertz, K. (2007) · Brain · doi:10.1093/brain/awl241 · Cited by 1,109
Entropies for detection of epilepsy in EEG
Kannathal, N., Choo, M. L., Acharya, U. R., & Sadasivan, P. K. (2005) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2005.06.012 · Cited by 753
Automatic recognition of epileptic seizures in the EEG
Gotman, J. (1982) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(82)90038-4 · Cited by 674
Polat, K., & Güneş, S. (2007) · Applied Mathematics and Computation · doi:10.1016/j.amc.2006.09.022 · Cited by 666
Prediction of epileptic seizures
Litt, B., & Echauz, J. (2002) · The Lancet Neurology · doi:10.1016/s1474-4422(02)00003-0 · Cited by 526
Recurrent neural networks employing Lyapunov exponents for EEG signals classification
GULER, N., UBEYLI, E., & GULER, I. (2005) · Expert Systems with Applications · doi:10.1016/j.eswa.2005.04.011 · Cited by 503
Artificial neural network based epileptic detection using time-domain and frequency-domain features
Srinivasan, V., Eswaran, C., & Sriraam, A. N. (2005) · Journal of Medical Systems · doi:10.1007/s10916-005-6133-1 · Cited by 417 · cited 2×
“[14] (2005) Time & frequency domain features, recurrent neural network (RNN) Z, S 99.”
BackgroundAnticipation of epileptic seizures from standard EEG recordings
Le Van Quyen, M., Martinerie, J., Navarro, V., Boon, P., D'Havé, M., Adam, C., Renault, B., Varela, F., & Baulac, M. (2001) · The Lancet · doi:10.1016/s0140-6736(00)03591-1 · Cited by 390
A neural-network-based detection of epilepsy
Nigam, V. P., & Graupe, D. (2004) · Neurological Research · doi:10.1179/016164104773026534 · Cited by 350
Lehnertz, K., & Elger, C. E. (1995) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00071-6 · Cited by 325
Characterization of EEG—A comparative study
Kannathal, N., Acharya, U. R., Lim, C. M., & Sadasivan, P. K. (2005) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2005.06.005 · Cited by 284
One-Class Novelty Detection for Seizure Analysis from Intracranial EEG
Gardner, A. B., Krieger, A. Μ., Vachtsevanos, G., & Litt, B. (2006) · doi:10.5555/1248547.1248584 · Cited by 270
Qu, H., & Gotman, J. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.552241 · Cited by 248
Signal Analysis: Time, Frequency, Scale and Structure
Allen, R. L., & Mills, D. W. (2003) · International Linear Collider · Cited by 240
Automatic Detection of Seizures and Spikes
Gotman, J. (1999) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199903000-00005 · Cited by 232
A multistage system to detect epileptiform activity in the EEG
Dingle, A. A., Jones, R. D., Carroll, G. J., & Fright, W. R. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.250582 · Cited by 199
Its Possible Use for Interictal Focus Localization, Seizure Anticipation, and Prevention
Lehnertz, K., Andrzejak, R. G., Arnhold, J., et al. (2001) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-200105000-00002 · Cited by 181
■ REVIEW : Chaos Theory and Epilepsy
Iasemidis, L. D., & Sackellares, J. C. (1996) · The Neuroscientist · doi:10.1177/107385849600200213 · Cited by 175
Automatic seizure detection in EEG using logistic regression and artificial neural network
Alkan, A., Koklukaya, E., & Subasi, A. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.04.009 · Cited by 168
Wavelet neural network classification of EEG signals by using AR model with MLE preprocessing
Subasi, A., Alkan, A., Koklukaya, E., & Kiymik, M. K. (2005) · Neural Networks · doi:10.1016/j.neunet.2005.01.006 · Cited by 167
Seizure prediction by nonlinear EEG analysis
Lehnertz, K., Mormann, F., Kreuz, T., Andrzejak, R. G., Rieke, C., David, P., & Elger, C. E. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1191451 · Cited by 166
Temporo-spatial patterns of pre-ictal spike activity in human temporal lobe epilepsy
Lange, H., Lieb, J. P., Engel, J., & Crandall, P. H. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90022-6 · Cited by 148
Geva, A. B., & Kerem, D. H. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.720198 · Cited by 132
New horizons in ambulatory electroencephalography
Waterhouse, E. J. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213629 · Cited by 129
An approach to seizure detection using an artificial neural network (ANN)
Webber, W. R., Lesser, R. P., Richardson, R. T., & Wilson, K. (1996) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(95)00277-4 · Cited by 121
Epileptic seizure detection: A nonlinear viewpoint
Päivinen, N., Lammi, S., Pitkänen, A., Nissinen, J., Penttonen, M., & Grönfors, T. (2005) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2005.04.006 · Cited by 115
Gabor, A. J. (1998) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(98)00043-1 · Cited by 112
Epileptic Seizure Detection Using Neural Fuzzy Networks
Sadati, N., Mohseni, H. R., & Maghsoudi, A. (2006) · Proceedings of ... IEEE International Conference on Fuzzy Systems · doi:10.1109/fuzzy.2006.1681772 · Cited by 108
Monitoring changing dynamics with correlation integrals: Case study of an epileptic seizure
Lerner, D. E. (1996) · Physica D Nonlinear Phenomena · doi:10.1016/0167-2789(96)00085-1 · Cited by 106
Computerized seizure detection of complex partial seizures
Murro, A. M., King, D. W., Smith, J. R., Gallagher, B. B., Flanigin, H. F., & Meador, K. J. (1991) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(91)90128-q · Cited by 92
McSharry, P., He, T., Smith, L., & Tarassenko, L. (2002) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345078 · Cited by 76
Nonlinear EEG analysis in epilepsy
Lehnertz, K. (2005) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2001.1020505 · Cited by 29
Support vector machines for seizure detection
Gonzalez-Vellon, B., Sanei, S., & Chambers, J. A. (2004) · IEEE International Symposium on Signal Processing and Information Technology (ISSPIT) · doi:10.1109/isspit.2003.1341076 · Cited by 20
Research works printed but not linked: 12
- 10.1109/51.740981 · doi:10.1109/51.740981
- 1973, Epilepsia, 14, 367, 10.1111/j.1528-1157.1973.tb03975.x · doi:10.1111/j.1528-1157.1973.tb03975.x
- 10.1016/0013-4694(93)90138-L · doi:10.1016/0013-4694(93)90138-l
- 1996, Physical Review E, 54, 6661, 10.1103/PhysRevE.54.6661 · doi:10.1103/physreve.54.6661
- 2006, Methods of Information in Medicine, 45, 610, 10.1055/s-0038-1634122 · doi:10.1055/s-0038-1634122
- 10.1007/s11517-006-0056-y · doi:10.1007/s11517-006-0056-y
- 10.1007/BF02441427 · doi:10.1007/bf02441427
- 2006, Journal of Machine Learning Research, 7, 1025
- 10.1016/S1388-2457(00)00259-5 · doi:10.1016/s1388-2457(00)00259-5
- 10.1088/0967-3334/25/4/012 · doi:10.1088/0967-3334/25/4/012
- 1958, Electroencephalography and Clinical Neurophysiology, 10, 371
- 1996, Time-Frequency Toolbox
Cited by
Automated EEG analysis of epilepsy: A review
Acharya, U. R., Vinitha Sree, S., Swapna, G., Martis, R. J., & Suri, J. S. (2013) · Knowledge-Based Systems · doi:10.1016/j.knosys.2013.02.014 · Cited by 837
Automated diagnosis of epileptic EEG using entropies
Acharya, U. R., Molinari, F., Sree, S. V., Chattopadhyay, S., Ng, K.-H., & Suri, J. S. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2011.07.007 · Cited by 626
Detection of epileptic electroencephalogram based on Permutation Entropy and Support Vector Machines
Nicolaou, N., & Georgiou, J. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2011.07.008 · Cited by 518
Application of entropies for automated diagnosis of epilepsy using EEG signals: A review
Acharya, U. R., Fujita, H., Sudarshan, V. K., Bhat, S., & Koh, J. E. W. (2015) · Knowledge-Based Systems · doi:10.1016/j.knosys.2015.08.004 · Cited by 492
Classification of Seizure and Nonseizure EEG Signals Using Empirical Mode Decomposition
Bajaj, V., & Pachori, R. B. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2181403 · Cited by 472
Metadata
- Authors
- Tzallas, A. T., Tsipouras, M. G., & Fotiadis, D. I.
- Venue
- Computational Intelligence and Neuroscience
- Publisher
- Wiley
- Published
- 2007
- Volume
- 2007
- Pages
- 1-13
- ISSN
- 1687-5265 (ISSN-L)
- 1687-5273
- OpenAlex
- W2078760541
- Cited by
- 473
- References
- 39
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.