Rethinking the Viability and Utility of Inhaled Insulin in Clinical Practice
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Despite considerable advances in pharmacotherapy and self-monitoring technologies in the last decades, a large percentage of adults with diabetes remain unsuccessful in achieving optimal glucose due to suboptimal medication adherence. Contributors to suboptimal adherence to insulin treatment include pain, inconvenience, and regimen complexity; however, a key driver is hypoglycemia. Improvements in the PK/PD characteristics of today’s SC insulins provide more physiologic coverage of basal and prandial insulin requirements than regular human insulin; however, they do not achieve the rapid on/rapid off characteristics of endogenously secreted insulin seen in healthy, nondiabetic individuals. Pulmonary administration of prandial insulin represents an attractive option that overcomes limitations of SC insulin by providing more a rapid onset of action and a faster return of action to baseline levels than SC administration of rapid-acting insulin analogs. This article reviews the unique PK/PD properties of a novel inhaled formulation that support its use in patient populations with T1D or T2D.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impact of Medication Adherence on Hospitalization Risk and Healthcare Cost
Sokol, M. C., McGuigan, K. A., Verbrugge, R. R., & Epstein, R. S. (2005) · Medical Care · doi:10.1097/01.mlr.0000163641.86870.af · Cited by 1,729
Phillips, L. S., Branch, W. T., Cook, C. B., Doyle, J. P., El-Kebbi, I. M., Gallina, D. L., Miller, C. D., Ziemer, D. C., & Barnes, C. S. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-135-9-200111060-00012 · Cited by 1,370
Miller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Ho, P. M., Rumsfeld, J. S., Masoudi, F. A., McClure, D. L., Plomondon, M. E., Steiner, J. F., & Magid, D. J. (2006) · Archives of Internal Medicine · doi:10.1001/archinte.166.17.1836 · Cited by 1,135
Achievement of Goals in U.S. Diabetes Care, 1999–2010
Ali, M. K., Bullard, K. M., Saaddine, J. B., Cowie, C. C., Imperatore, G., & Gregg, E. W. (2013) · New England Journal of Medicine · doi:10.1056/nejmsa1213829 · Cited by 979 · cited 1×
“Despite considerable advances in pharmacotherapy, insulin delivery systems, and self-monitoring technologies in the last decades, a large percentage of adults with diabetes remain unsuccessful in achieving optimal glucose control, reflected by not reaching their HbA1c goals [15, 16].”
BackgroundRisk of hypoglycaemia in types 1 and 2 diabetes: Effects of treatment modalities and their duration
UK Hypoglycaemia Study Group (2007) · Diabetologia · doi:10.1007/s00125-007-0599-y · Cited by 825
Weng, J., Li, Y., Xu, W., Shi, L., Zhang, Q., Zhu, D., Hu, Y., Zhou, Z., Yan, X., Tian, H., et al. (2008) · The Lancet · doi:10.1016/s0140-6736(08)60762-x · Cited by 780
Wild, D., von Maltzahn, R., Brohan, E., Christensen, T., Clauson, P., & Gonder-Frederick, L. (2007) · Patient Education and Counseling · doi:10.1016/j.pec.2007.05.003 · Cited by 545
Quality of Diabetes Care in U.S. Academic Medical Centers
Grant, R. W., Buse, J. B., Meigs, J. B., & for the University HealthSystem Consortium (UHC) Diabetes Benchmarking Project Team (2005) · Diabetes Care · doi:10.2337/diacare.28.2.337 · Cited by 311
Ilkova, H., Glaser, B., Tunçkale, A., Bagriaçik, N., & Cerasi, E. (1997) · Diabetes Care · doi:10.2337/diacare.20.9.1353 · Cited by 269
Achievement of Glycated Hemoglobin Goals in the US Remains Unchanged Through 2014
Carls, G., Huynh, J., Tuttle, E., Yee, J., & Edelman, S. V. (2017) · Diabetes Therapy · doi:10.1007/s13300-017-0280-5 · Cited by 228 · cited 1×
“Despite considerable advances in pharmacotherapy, insulin delivery systems, and self-monitoring technologies in the last decades, a large percentage of adults with diabetes remain unsuccessful in achieving optimal glucose control, reflected by not reaching their HbA1c goals [15, 16].”
BackgroundClinical Inertia Contributes to Poor Diabetes Control in a Primary Care Setting
Ziemer, D. C., Miller, C. D., Rhee, M. K., Doyle, J. P., Watkins, C., Cook, C. B., Gallina, D. L., El-Kebbi, I. M., Barnes, C. S., Dunbar, V. G., et al. (2005) · The Diabetes Educator · doi:10.1177/0145721705279050 · Cited by 208
Haugstvedt, A., Wentzel‐Larsen, T., Graue, M., Søvik, O., & Rokne, B. (2010) · Diabetic Medicine · doi:10.1111/j.1464-5491.2009.02867.x · Cited by 172
Longitudinal effects of medication nonadherence on glycemic control
Egede, L. E., Gebregziabher, M., Echols, C., & Lynch, C. P. (2014) · Annals of Pharmacotherapy · doi:10.1177/1060028014526362 · Cited by 146
Cariou, B., Fontaine, P., Eschwege, E., Lièvre, M., Gouet, D., Huet, D., Madani, S., Lavigne, S., & Charbonnel, B. (2015) · Diabetes & Metabolism · doi:10.1016/j.diabet.2014.10.007 · Cited by 129
Bode, B. W., McGill, J. B., Lorber, D. L., Gross, J. L., Chang, P.-C., Bregman, D. B., & for the Affinity 1 Study Group (2015) · Diabetes Care · doi:10.2337/dc15-0075 · Cited by 114 · cited 17×
“Needle phobia in a subgroup of patients with diabetes, which often goes unrecognized or unreported, contributes to patient inertia and manifests as resistance to starting insulin injections even as T2D progresses from insulin resistance to total insulin deficiency [23, 24].”
BackgroundMethodInfluentialHYPOS-1 Study Group of AMD, Giorda, C. B., Ozzello, A., Gentile, S., Aglialoro, A., Chiambretti, A., Baccetti, F., Gentile, F. M., Lucisano, G., Nicolucci, A., et al. (2015) · Acta Diabetologica · doi:10.1007/s00592-015-0713-4 · Cited by 97
Rosenstock, J., Franco, D., Korpachev, V., Shumel, B., Ma, Y., Baughman, R., Amin, N., McGill, J. B., & for the Affinity 2 Study Group (2015) · Diabetes Care · doi:10.2337/dc15-0629 · Cited by 43 · cited 14×
“Needle phobia in a subgroup of patients with diabetes, which often goes unrecognized or unreported, contributes to patient inertia and manifests as resistance to starting insulin injections even as T2D progresses from insulin resistance to total insulin deficiency [23, 24].”
BackgroundInfluential
Cited by
Davies, M. J., Aroda, V. R., Collins, B. S., Gabbay, R. A., Green, J., Maruthur, N. M., Rosas, S. E., Del Prato, S., Mathieu, C., Mingrone, G., et al. (2022) · Diabetes Care · doi:10.2337/dci22-0034 · Cited by 2,104
Davies, M. J., Aroda, V. R., Collins, B. S., Gabbay, R. A., Green, J., Maruthur, N. M., Rosas, S. E., Del Prato, S., Mathieu, C., Mingrone, G., et al. (2022) · Diabetologia · doi:10.1007/s00125-022-05787-2 · Cited by 1,048
Intranasal drug delivery: opportunities and toxicologic challenges during drug development
Keller, L.-A., Merkel, O., & Popp, A. (2022) · Drug Delivery and Translational Research · doi:10.1007/s13346-020-00891-5 · Cited by 591
Akturk, H. K., Snell-Bergeon, J. K., Rewers, A., Klaff, L. J., Bode, B. W., Peters, A. L., Bailey, T. S., & Garg, S. K. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0200 · Cited by 70
“A comparison of glucose response, measured by glucose infusion rate (GIR) showed that 12 U of TI had a similar but faster peak compared with 8 U of insulin lispro.(16) Equivalent TI units are generally 1.”
BackgroundMethodMcGill, J. B., Peters, A., Buse, J. B., Steiner, S., Tran, T., Pompilio, F. M., & Kendall, D. M. (2020) · Clinical Drug Investigation · doi:10.1007/s40261-020-00958-8 · Cited by 35
Metadata
- Authors
- Heinemann, L., & Parkin, C. G.
- Venue
- Journal of Diabetes Research
- Publisher
- Wiley
- Published
- 2018
- Volume
- 2018
- Pages
- 1-9
- ISSN
- 2314-6745 (ISSN-L)
- 2314-6753
- OpenAlex
- W2790926469
- Cited by
- 48
- References
- 18
- FWCI
- 3.41
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.