Metabolic Imaging by Hyperpolarized 13C Magnetic Resonance Imaging for In vivo Tumor Diagnosis
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
The “Warburg effect,” an elevation in aerobic glycolysis, may be a fundamental property of cancer cells. For cancer diagnosis and treatment, it would be valuable if elevated glycolytic metabolism could be quantified in an image in animals and humans. The pyruvate molecule is at the metabolic crossroad for energy delivery inside the cell, and with a noninvasive measurement of the relative transformation of pyruvate into lactate and alanine within a biologically relevant time frame (seconds), it may be possible to quantify the glycolytic status of the cells. We have examined the metabolism after i.v. injection of hyperpolarized 13C-pyruvate in rats with implanted P22 tumors. The strongly enhanced nuclear magnetic resonance signal generated by the hyperpolarization techniques allows mapping of pyruvate, lactate, and alanine in a 5 × 5 × 10 mm3 imaging voxel using a 1.5 T magnetic resonance scanner. The magnetic resonance scanning (chemical shift imaging) was initiated 24 seconds after the pyruvate injection and had a duration of 14 seconds. All implanted tumors showed significantly higher lactate content than the normal tissue. The results indicate that noninvasive quantification of localized Warburg effect may be possible. (Cancer Res 2006; 66(22): 10855-60)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Increase in signal-to-noise ratio of > 10,000 times in liquid-state NMR
Ardenkjær-Larsen, J. H., Fridlund, B., Gram, A., Hansson, G., Hansson, L., Lerche, M. H., Servin, R., Thaning, M., & Golman, K. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1733835100 · Cited by 2,861
Self-citationXu, R.-H., Pelicano, H., Zhou, Y., Carew, J. S., Feng, L., Bhalla, K. N., Keating, M. J., & Huang, P. (2005) · Cancer Research · doi:10.1158/0008-5472.613.65.2 · Cited by 835
Combretastatin A-4, an agent that displays potent and selective toxicity toward tumor vasculature.
Dark, G. G., Hill, S. A., Prise, V. E., Tozer, G. M., Pettit, G. R., & Chaplin, D. J. (1997) · PubMed · Cited by 694
Studies of human tumors by MRS: A review
Negendank, W. (1992) · NMR in Biomedicine · doi:10.1002/nbm.1940050518 · Cited by 660
Golman, K., in ‘t Zandt, R., & Thaning, M. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0601319103 · Cited by 659
Self-citationHowe, F. A., Barton, S. J., Cudlip, S. A., Stubbs, M., Saunders, D. E., Murphy, M., Wilkins, P., Opstad, K. S., Doyle, V. L., McLean, M. A., et al. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10367 · Cited by 539
Molecular imaging with endogenous substances
Golman, K., Ardenkjær-Larsen, J. H., Petersson, J. S., Månsson, S., & Leunbach, I. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1733836100 · Cited by 427
Self-citationKoukourakis, M. I., Giatromanolaki, A., Sivridis, E., Gatter, K. C., & Harris, A. L. (2005) · Neoplasia · doi:10.1593/neo.04373 · Cited by 214 · cited 1×
“It is known that in cancer cells, pyruvate is abundantly transformed to lactate through anaerobic glycolysis (14).”
BackgroundMR spectroscopy quantitation: a review of time‐domain methods
Vanhamme, L., Sundin, T., Hecke, P. V., & Huffel, S. V. (2001) · NMR in Biomedicine · doi:10.1002/nbm.695 · Cited by 213
Energy Boost: The Warburg Effect Returns in a New Theory of Cancer
Garber, K. (2004) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/96.24.1805 · Cited by 212
Board, M., Humm, S., & Newsholme, E. A. (1990) · Biochemical Journal · doi:10.1042/bj2650503 · Cited by 203
MRI for assessing antivascular cancer treatments
Padhani, A. R. (2003) · British Journal of Radiology · doi:10.1259/bjr/15334380 · Cited by 151
Maxwell, R. J., Wilson, J., Prise, V. E., Vojnovic, B., Rustin, G. J. S., Lodge, M. A., & Tozer, G. M. (2002) · NMR in Biomedicine · doi:10.1002/nbm.754 · Cited by 104
Prise, V. E., Honess, D. J., Stratford, M. R. L., Wilson, J., & Tozer, G. M. (2002) · International Journal of Oncology · doi:10.3892/ijo.21.4.717 · Cited by 82
Application of metabolic-control logic to fuel utilization and its significance in tumor cells
Newsholme, E. A., & Mary Board (1991) · Advances in Enzyme Regulation · doi:10.1016/0065-2571(91)90015-e · Cited by 71
Magnetic Resonance Imaging Visualization of Hyaluronidase in Ovarian Carcinoma
Shiftan, L., Israely, T., Cohen, M., Frydman, V., Dafni, H., Stern, R., & Neeman, M. (2005) · Cancer Research · doi:10.1158/0008-5472.can-04-3947 · Cited by 60
Modification of tumour blood flow using the hypertensive agent, angiotensin II
Tozer, G., & Shaffi, K. M. (1993) · British Journal of Cancer · doi:10.1038/bjc.1993.180 · Cited by 44
The biochemistry of living tissues: Examination by MRS
Ross, B. D. (1992) · NMR in Biomedicine · doi:10.1002/nbm.1940050504 · Cited by 44
Evidence for the compartmentation of pyruvate metabolism in perfused rat skeletal muscle
Schadewaldt, P., Münch, U., & Staib, W. (1983) · Biochemical Journal · doi:10.1042/bj2160761 · Cited by 15
Preferential accumulation of 11C in human brain tumors after intravenous injection of 11C-1-pyruvate
Tsukiyama, T., Hara, T., Iio, M., et al. (1986) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/bf00251978 · Cited by 8
Cited by
Metabolomics: the apogee of the omics trilogy
Patti, G. J., Yanes, O., & Siuzdak, G. (2012) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3314 · Cited by 2,571
Crosby, D., Bhatia, S., Brindle, K. M., Coussens, L. M., Dive, C., Emberton, M., Esener, S., Fitzgerald, R. C., Gambhir, S. S., Kuhn, P., et al. (2022) · Science · doi:10.1126/science.aay9040 · Cited by 1,379
“…transit times of the photons emitted by the object generating the image signal provide a greater signal to noise ratio, and hyperpolarized MRI ( 98 ), where hyperpolarised carbon-13-containing moleculaes enable the collection of perfusion and metabolic information in addition to structural…”
Challenges for Molecular Magnetic Resonance Imaging
Terreno, E., Castelli, D. D., Viale, A., & Aime, S. (2010) · Chemical Reviews · doi:10.1021/cr100025t · Cited by 1,204
Gold Nanoparticles for In Vitro Diagnostics
Zhou, W., Gao, X., Liu, D., & Chen, X. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00100 · Cited by 901
Day, S. E., Kettunen, M. I., Gallagher, F. A., Hu, D.-E., Lerche, M., Wolber, J., Golman, K., Ardenkjaer-Larsen, J. H., & Brindle, K. M. (2007) · Nature Medicine · doi:10.1038/nm1650 · Cited by 883
Self-citation
Metadata
- Authors
- Golman, K., Zandt, R. I., Lerche, M., Pehrson, R., & Ardenkjaer-Larsen, J. H.
- Venue
- Cancer Research
- Published
- 2006-11-15
- Volume
- 66
- Issue
- 22
- Pages
- 10855-10860
- ISSN
- 0008-5472 (ISSN-L)
- 1538-7445
- OpenAlex
- W1975107578
- Cited by
- 591
- References
- 20
- FWCI
- 11.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.