Phosphorescent Light–Emitting Iridium Complexes Serve as a Hypoxia-Sensing Probe for Tumor Imaging in Living Animals
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Iridium complex is a promising organic light–emitting diode material for next generation video displays that emits phosphorescence quenched by oxygen. We used this oxygen-quenching feature for imaging tumor hypoxia. Red light–emitting Ir(btp)2(acac) (BTP) presented hypoxia-dependent light emission in culture cell lines, whose intensity was in parallel with hypoxia-inducible factor-1α images. BTP was further applied to imaging five nude mouse transplanted with tumors. All tumors presented a bright BTP-emitting image even 5 minutes after injection. The minimal image recognition size was ∼2 mm in diameter. By morphologic examination and phosphorescence lifetime measurement, BTP appeared to localize to the tumor cells. Because BTP is easily modifiable, we synthesized BTP analogues with a longer excitation/emission wavelength. One of them, BTPHSA, depicted clear imaging from tumors transplanted 6 to 7 mm deep from the skin surface. We suggest that iridium complex materials have a vast potential for imaging hypoxic lesions such as tumor tissues. Cancer Res; 70(11); 4490–8. ©2010 AACR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lamansky, S., Djurovich, P., Murphy, D., Abdel-Razzaq, F., Lee, H.-E., Adachi, C., Burrows, P. E., Forrest, S. R., & Thompson, M. E. (2001) · Journal of the American Chemical Society · doi:10.1021/ja003693s · Cited by 2,812
Tumor Hypoxia: Definitions and Current Clinical, Biologic, and Molecular Aspects
Hockel, M., & Vaupel, P. (2001) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/93.4.266 · Cited by 2,662
Oxygen sensing by HIF hydroxylases
Schofield, C. J., & Ratcliffe, P. J. (2004) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1366 · Cited by 2,068
Hypoxia-inducible factor-1alpha is a positive factor in solid tumor growth.
Ryan, H. E., Poloni, M., McNulty, W., Elson, D., Gassmann, M., Arbeit, J. M., & Johnson, R. S. (2000) · PubMed · Cited by 903
Nitroimidazoles and imaging hypoxia
Nunn, A., Linder, K., & Strauss, H. W. (1995) · European Journal of Nuclear Medicine · doi:10.1007/bf01081524 · Cited by 387
Imaging oxygenation of human tumours
Padhani, A. R., Krohn, K. A., Lewis, J. S., & Alber, M. (2007) · European Radiology · doi:10.1007/s00330-006-0431-y · Cited by 328
Oxyphor R2 and G2: phosphors for measuring oxygen by oxygen-dependent quenching of phosphorescence
Dunphy, I., Vinogradov, S. A., & Wilson, D. F. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00384-6 · Cited by 288
(2006) · Principles of Fluorescence Spectroscopy · doi:10.1007/978-0-387-46312-4_8 · Cited by 278
Phosphorescent Oxygen Sensor with Dendritic Protection and Two-Photon Absorbing Antenna
Briñas, R. P., Troxler, T., Hochstrasser, R. M., & Vinogradov, S. A. (2005) · Journal of the American Chemical Society · doi:10.1021/ja052947c · Cited by 267
Varghese, A. J., Gulyás, S., & Mohindra, J. K. (1976) · PubMed · Cited by 195
Cited by
Nanochemistry and Nanomedicine for Nanoparticle-based Diagnostics and Therapy
Chen, G., Roy, I., Yang, C., & Prasad, P. N. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00148 · Cited by 1,499
Macro-/micro-environment-sensitive chemosensing and biological imaging
Yang, Z., Cao, J., He, Y., Yang, J. H., Kim, T., Peng, X., & Kim, J. S. (2014) · Chem. Soc. Rev. · doi:10.1039/c4cs00051j · Cited by 875
Hirata, S., Totani, K., Zhang, J., Yamashita, T., Kaji, H., Marder, S. R., Watanabe, T., & Adachi, C. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201203706 · Cited by 851
Comparison of 2D- and 3D-culture models as drug-testing platforms in breast cancer
IMAMURA, Y., MUKOHARA, T., SHIMONO, Y., FUNAKOSHI, Y., CHAYAHARA, N., TOYODA, M., KIYOTA, N., TAKAO, S., KONO, S., NAKATSURA, T., et al. (2015) · Oncology Reports · doi:10.3892/or.2015.3767 · Cited by 845
Chemical Design and Synthesis of Functionalized Probes for Imaging and Treating Tumor Hypoxia
Liu, J.-N., Bu, W., & Shi, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00525 · Cited by 838
Hirata, S. (2017) · Advanced Optical Materials · doi:10.1002/adom.201700116 · Cited by 785
The Art of Fluorescence Imaging with Chemical Sensors
Schäferling, M. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201105459 · Cited by 721
You, Y., & Nam, W. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35171d · Cited by 668
Lo, K. K.-W. (2015) · Accounts of Chemical Research · doi:10.1021/acs.accounts.5b00211 · Cited by 566
Ultrasensitive Near-Infrared Fluorescence-Enhanced Probe for in Vivo Nitroreductase Imaging
Li, Y., Sun, Y., Li, J., Su, Q., Yuan, W., Dai, Y., Han, C., Wang, Q., Feng, W., & Li, F. (2015) · Journal of the American Chemical Society · doi:10.1021/jacs.5b04097 · Cited by 516
3D cell culture systems modeling tumor growth determinants in cancer target discovery
Thoma, C. R., Zimmermann, M., Agarkova, I., Kelm, J. M., & Krek, W. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.03.001 · Cited by 478
Indicators for optical oxygen sensors
Quaranta, M., Borisov, S. M., & Klimant, I. (2012) · Bioanalytical Reviews · doi:10.1007/s12566-012-0032-y · Cited by 452
Biological detection by optical oxygen sensing
Papkovsky, D. B., & Dmitriev, R. I. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60131e · Cited by 444
Transition metal complexes as photosensitisers in one- and two-photon photodynamic therapy
McKenzie, L. K., Bryant, H. E., & Weinstein, J. A. (2019) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2018.03.020 · Cited by 431
He, Z., Gao, H., Zhang, S., Zheng, S., Wang, Y., Zhao, Z., Ding, D., Yang, B., Zhang, Y., & Yuan, W. Z. (2019) · Advanced Materials · doi:10.1002/adma.201807222 · Cited by 386
Self-citationHypoxia-Sensitive Fluorescent Probes for in Vivo Real-Time Fluorescence Imaging of Acute Ischemia
Kiyose, K., Hanaoka, K., Oushiki, D., Nakamura, T., Kajimura, M., Suematsu, M., Nishimatsu, H., Yamane, T., Terai, T., Hirata, Y., et al. (2010) · Journal of the American Chemical Society · doi:10.1021/ja105937q · Cited by 373
Hypoxia-specific ultrasensitive detection of tumours and cancer cells in vivo
Zheng, X., Wang, X., Mao, H., Wu, W., Liu, B., & Jiang, X. (2015) · Nature Communications · doi:10.1038/ncomms6834 · Cited by 362
Tumor microenvironment-responsive intelligent nanoplatforms for cancer theranostics
Gong, F., Yang, N., Wang, X., Zhao, Q., Chen, Q., Liu, Z., & Cheng, L. (2020) · Nano Today · doi:10.1016/j.nantod.2020.100851 · Cited by 359
Cyclometalated iridium(III) luminescent complexes in therapy and phototherapy
Zamora, A., Vigueras, G., Rodríguez, V., Santana, M. D., & Ruiz, J. (2018) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2018.01.010 · Cited by 345
Liu, J., Liu, Y., Bu, W., Bu, J., Sun, Y., Du, J., & Shi, J. (2014) · Journal of the American Chemical Society · doi:10.1021/ja5042989 · Cited by 332
Development of Azo‐Based Fluorescent Probes to Detect Different Levels of Hypoxia
Piao, W., Tsuda, S., Tanaka, Y., Maeda, S., Liu, F., Takahashi, S., Kushida, Y., Komatsu, T., Ueno, T., Terai, T., et al. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201305784 · Cited by 293
Fate-mapping post-hypoxic tumor cells reveals a ROS-resistant phenotype that promotes metastasis
Godet, I., Shin, Y. J., Ju, J. A., Ye, I. C., Wang, G., & Gilkes, D. M. (2019) · Nature Communications · doi:10.1038/s41467-019-12412-1 · Cited by 273
Hypoxia-responsive nanoparticle based drug delivery systems in cancer therapy: An up-to-date review
Kumari, R., Sunil, D., & Ningthoujam, R. S. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.12.041 · Cited by 263
Molecular imaging of the tumor microenvironment
Zhou, Z., & Lu, Z.-R. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.07.012 · Cited by 253
Luminescent chemosensors by using cyclometalated iridium(iii) complexes and their applications
Ma, D.-L., Lin, S., Wang, W., Yang, C., & Leung, C.-H. (2017) · Chemical Science · doi:10.1039/c6sc04175b · Cited by 232
Optical probes and techniques for O2 measurement in live cells and tissue
Dmitriev, R. I., & Papkovsky, D. B. (2012) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-011-0914-0 · Cited by 230
Iridium(iii) complexes as therapeutic and bioimaging reagents for cellular applications
Lo, K. K.-W., & Zhang, K. Y. (2012) · RSC Advances · doi:10.1039/c2ra20967e · Cited by 227
Shi, H., Ma, X., Zhao, Q., Liu, B., Qu, Q., An, Z., Zhao, Y., & Huang, W. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201400647 · Cited by 224
Recent Advances in the Design of Targeted Iridium(III) Photosensitizers for Photodynamic Therapy
Huang, H., Banerjee, S., & Sadler, P. J. (2018) · ChemBioChem · doi:10.1002/cbic.201800182 · Cited by 206
Dual-Phosphorescent Iridium(III) Complexes Extending Oxygen Sensing from Hypoxia to Hyperoxia
Zhang, K. Y., Gao, P., Sun, G., Zhang, T., Li, X., Liu, S., Zhao, Q., Lo, K. K.-W., & Huang, W. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.8b02492 · Cited by 205
Méhes, G., Goushi, K., Potscavage, W. J., & Adachi, C. (2014) · Organic Electronics · doi:10.1016/j.orgel.2014.05.027 · Cited by 179
Thomas, H., Pastoetter, D. L., Gmelch, M., Achenbach, T., Schlögl, A., Louis, M., Feng, X., & Reineke, S. (2020) · Advanced Materials · doi:10.1002/adma.202000880 · Cited by 178
Phosphorescence bioimaging using cyclometalated Ir(III) complexes
You, Y. (2013) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2013.05.023 · Cited by 165
H. Dovmark, T., Hulikova, A., A. Niederer, S., D. Vaughan‐Jones, R., & Swietach, P. (2018) · The FASEB Journal · doi:10.1096/fj.201700480r · Cited by 28
Metadata
- Authors
- Zhang, S., Hosaka, M., Yoshihara, T., Negishi, K., Iida, Y., Tobita, S., & Takeuchi, T.
- Venue
- Cancer Research
- Published
- 2010-06-01
- Volume
- 70
- Issue
- 11
- Pages
- 4490-4498
- ISSN
- 0008-5472 (ISSN-L)
- 1538-7445
- OpenAlex
- W2022396615
- Cited by
- 349
- References
- 19
- FWCI
- 8.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.