A Microfluidic Cancer-on-Chip Platform Predicts Drug Response Using Organotypic Tumor Slice Culture
Open accessPublished version of a preprint
The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
Optimal treatment of cancer requires diagnostic methods to facilitate therapy choice and prevent ineffective treatments. Direct assessment of therapy response in viable tumor specimens could fill this diagnostic gap. Therefore, we designed a microfluidic platform for assessment of patient treatment response using tumor tissue slices under precisely controlled growth conditions. The optimized Cancer-on-Chip (CoC) platform maintained viability and sustained proliferation of breast and prostate tumor slices for 7 days. No major changes in tissue morphology or gene expression patterns were observed within this time frame, suggesting that the CoC system provides a reliable and effective way to probe intrinsic chemotherapeutic sensitivity of tumors. The customized CoC platform accurately predicted cisplatin and apalutamide treatment response in breast and prostate tumor xenograft models, respectively. The culture period for breast cancer could be extended up to 14 days without major changes in tissue morphology and viability. These culture characteristics enable assessment of treatment outcomes and open possibilities for detailed mechanistic studies. SIGNIFICANCE: The Cancer-on-Chip platform with a 6-well plate design incorporating silicon-based microfluidics can enable optimal patient-specific treatment strategies through parallel culture of multiple tumor slices and diagnostic assays using primary tumor material.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures



![Figure 4. Breast PDX tumor tissue slices cultured in ex vivo condition and in CoC platform for up to 14 days. A, We used five independent breast PDX tumors in five independent experiments to establish optimized culture condition for tumor slices in our CoC platform. From each breast PDX tumor, tissue slices were cultured in ex vivo 6-well plate and CoC device for up to 14 days and evaluated for tissue morphology [hematoxylin and eosin (H&E) staining], DAPI (blue nuclei), proliferation (EdU incorporation, red nuclei), Ki67 (brown nuclei), and apoptosis (TUNEL staining, green nuclei). Scale bar, 50 μm. B and C, Quantification of the fraction of EdU-positive and TUNEL-positive cells for 5 breast PDX tissue slices (derived from individual PDX tumors) cultured for up to day 7 (B) and day 14 (C). For each breast PDX tumor and each condition, tissue slices were imaged, and ten random fields of view were quantified from each breast PDX slice. Each data point in the graph represents one image field. Error bar represents the SEM for the five independent tumors performed in five independent experiments. D, Representative image showing breast PDX tumors (n = 3) labeled with geminin (red nuclei) and DAPI (blue nuclei). Scale bar, 50 μm. E, QIBC analysis of three independent breast PDX tumors with more than 3,000 cells analyzed for each are shown in each condition. F, Quantification of geminin-positive cells showed CoC at day 7 had similar cell proliferation profile as in day 0 than ex vivo condition. Error bar, SEM. NS, not significant; D0, day 0; D7, day 7, D14, day 14. NS, not significant; *, P < 0.05; **, P < 0.01; ***, P < 0.001; ****, P < 0.0001.](https://figures.cochat.ai/paper-figures/417f03dd7fe24da08b8fe93a59973cda/a-microfluidic-cancer-on-chip-platform-predicts-drug-response-using-organotypic-figure-4.jpg)

Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Interestingly, the prostate cancer tumor slices maintained their viability, morphology, proliferation potential and gene expression profiles in the microfluidic device for 7 days, allowing for the assessment of the chemotherapeutic sensitivity of the tumors.”
From Microphysiological systems as models for immunologically ‘cold’ tumors (2024) · cites this paper as Chakrabarty et al., 2022
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“The administration of apalutamide resulted in decreased AR expression, an increase in apoptotic cells and a significant decrease in proliferation, which replicates the effect of antiandrogen treatment in ex vivo cultures and in vivo.”
From Microphysiological systems as models for immunologically ‘cold’ tumors (2024) · cites this paper as Chakrabarty et al., 2022
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Sequence Alignment/Map format and SAMtools
Li, H., Handsaker, B., Wysoker, A., Fennell, T., Ruan, J., Homer, N., Marth, G., Abecasis, G., Durbin, R., & 1000 Genome Project Data Processing Subgroup (2009) · Bioinformatics · doi:10.1093/bioinformatics/btp352 · Cited by 62,041 · cited 1×
“251 Samtools and PICARD programs were used on the aligned files to obtain the mapping statistics and other 252 RNAseq metrics(29).”
MethodRobinson, M. D., McCarthy, D. J., & Smyth, G. K. (2010) · Bioinformatics · doi:10.1093/bioinformatics/btp616 · Cited by 41,364 · cited 1×
“8 Bioconductor package edgeR was used for differential expression analysis (33).”
MethodfeatureCounts: an efficient general purpose program for assigning sequence reads to genomic features
Liao, Y., Smyth, G. K., & Shi, W. (2014) · Bioinformatics · doi:10.1093/bioinformatics/btt656 · Cited by 27,219 · cited 1×
“We used 255 the feature Counts program to generate the count table for differential expression analysis (32).”
MethodGraph-based genome alignment and genotyping with HISAT2 and HISAT-genotype
Kim, D., Paggi, J. M., Park, C., Bennett, C., & Salzberg, S. L. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0201-4 · Cited by 15,022 · cited 1×
“The 249 trimmed and processed fastqc files were separately aligned to human and mouse genomes (GRCh38 and 250 GRCm38 versions) downloaded from GENCODE respectively using HISAT2 (a splice aware aligner)(28).”
MethodStringTie enables improved reconstruction of a transcriptome from RNA-seq reads
Pertea, M., Pertea, G. M., Antonescu, C. M., Chang, T.-C., Mendell, J. T., & Salzberg, S. L. (2015) · Nature Biotechnology · doi:10.1038/nbt.3122 · Cited by 14,298 · cited 1×
“Expression analysis was performed for both human and mouse mapped reads using 254 StringTie using the reference only approach and the gene abundance tables were obtained (31).”
MethodPatient-derived organoids model treatment response of metastatic gastrointestinal cancers
Vlachogiannis, G., Hedayat, S., Vatsiou, A., Jamin, Y., Fernández-Mateos, J., Khan, K., Lampis, A., Eason, K., Huntingford, I., Burke, R., et al. (2018) · Science · doi:10.1126/science.aao2774 · Cited by 2,096 · cited 1×
“Defining features of this 405 microfluidic system are: (1) relatively large (tumor) tissue slices can be loaded, (2) flow of culture media 406 both above and under the tissue slice to sustain constant delivery of nutrients and gasses and removal of 407 waste products, (3) mainly silicon-based components, (4) standard…”
BackgroundRottenberg, S., Jaspers, J. E., Kersbergen, A., van der Burg, E., Nygren, A. O. H., Zander, S. A. L., Derksen, P. W. B., de Bruin, M., Zevenhoven, J., Lau, A., et al. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0806092105 · Cited by 956 · cited 1×
“For example, (breast) cancer patients with pathogenic 77 BRCA1/2 mutations are homologous recombination (HR) deficient, which makes them eligible for PARP 78 inhibitor (PARPi) therapy (6).”
BackgroundSelf-citationHuman 3D vascularized organotypic microfluidic assays to study breast cancer cell extravasation
Jeon, J. S., Bersini, S., Gilardi, M., Dubini, G., Charest, J. L., Moretti, M., & Kamm, R. D. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1417115112 · Cited by 723 · cited 1×
“engineering for controlled culture of cells or tissue specimens (13,14).”
BackgroundFLEXBAR—Flexible Barcode and Adapter Processing for Next-Generation Sequencing Platforms
Dodt, M., Roehr, J., Ahmed, R., & Dieterich, C. (2012) · Biology · doi:10.3390/biology1030895 · Cited by 719 · cited 1×
“Adapter trimming and removal 248 of homo-polymers were performed using FLEXBAR and reads less than 25 bases were discarded (27).”
MethodLukas, C., Savic, V., Bekker-Jensen, S., Doil, C., Neumann, B., Sølvhøj Pedersen, R., Grøfte, M., Chan, K. L., Hickson, I. D., Bartek, J., et al. (2011) · Nature Cell Biology · doi:10.1038/ncb2201 · Cited by 667 · cited 1×
“A similar phenomenon has been observed before in cells and was shown to be due to 446 replication stress (50), suggesting that the culture conditions presented here led to similar replication 447 problems.”
BackgroundShirure, V. S., Bi, Y., Curtis, M. B., Lezia, A., Goedegebuure, M. M., Goedegebuure, S. P., Aft, R., Fields, R. C., & George, S. C. (2018) · Lab on a Chip · doi:10.1039/c8lc00596f · Cited by 316 · cited 1×
“engineering for controlled culture of cells or tissue specimens (13,14).”
BackgroundOne mouse, one patient paradigm: New avatars of personalized cancer therapy
Malaney, P., Nicosia, S. V., & Davé, V. (2014) · Cancer Letters · doi:10.1016/j.canlet.2013.10.010 · Cited by 289 · cited 1×
“Defining features of this 405 microfluidic system are: (1) relatively large (tumor) tissue slices can be loaded, (2) flow of culture media 406 both above and under the tissue slice to sustain constant delivery of nutrients and gasses and removal of 407 waste products, (3) mainly silicon-based components, (4) standard…”
BackgroundInterstitial fluid flow in cancer: implications for disease progression and treatment
Munson, J., & Shieh, A. (2014) · Cancer Management and Research · doi:10.2147/cmar.s65444 · Cited by 235
Permeability thickness dependence of polydimethylsiloxane (PDMS) membranes
Firpo, G., Angeli, E., Repetto, L., & Valbusa, U. (2015) · Journal of Membrane Science · doi:10.1016/j.memsci.2014.12.043 · Cited by 230
Seo, Y. D., Jiang, X., Sullivan, K. M., Jalikis, F. G., Smythe, K. S., Abbasi, A., Vignali, M., Park, J. O., Daniel, S. K., Pollack, S. M., et al. (2019) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-19-0081 · Cited by 227
ter Brugge, P., Kristel, P., van der Burg, E., Boon, U., de Maaker, M., Lips, E., Mulder, L., de Ruiter, J., Moutinho, C., Gevensleben, H., et al. (2016) · Journal of the National Cancer Institute · doi:10.1093/jnci/djw148 · Cited by 211 · cited 4×
“A cisplatin-resistant subline was created by repeated cisplatin treatment (T250), as described previously (2).”
MethodInfluentialSelf-citationA Tumor‐on‐a‐Chip System with Bioprinted Blood and Lymphatic Vessel Pair
Cao, X., Ashfaq, R., Cheng, F., Maharjan, S., Li, J., Ying, G., Hassan, S., Xiao, H., Yue, K., & Zhang, Y. S. (2019) · Advanced Functional Materials · doi:10.1002/adfm.201807173 · Cited by 198
Micro-dissected tumor tissues on chip: an ex vivo method for drug testing and personalized therapy
Astolfi, M., Péant, B., Lateef, M. A., Rousset, N., Kendall-Dupont, J., Carmona, E., Monet, F., Saad, F., Provencher, D., Mes-Masson, A.-M., et al. (2016) · Lab on a Chip · doi:10.1039/c5lc01108f · Cited by 182
Cao, X., Coyle, J. P., Xiong, R., Wang, Y., Heflich, R. H., Ren, B., Gwinn, W. M., Hayden, P. J., & Rojanasakul, L. W. (2020) · In Vitro Cellular & Developmental Biology - Animal · doi:10.1007/s11626-020-00517-7 · Cited by 177
van Weerden, W. M., de Ridder, C. M., Verdaasdonk, C. L., Romijn, J. C., van der Kwast, T., Schröder, F. H., & van Steenbrugge, G. J. (1996) · Europe PMC (PubMed Central) · Cited by 172
XenofilteR: computational deconvolution of mouse and human reads in tumor xenograft sequence data
Kluin, R. J. C., Kemper, K., Kuilman, T., de Ruiter, J. R., Iyer, V., Forment, J. V., Cornelissen-Steijger, P., de Rink, I., ter Brugge, P., Song, J.-Y., et al. (2018) · BMC Bioinformatics · doi:10.1186/s12859-018-2353-5 · Cited by 162 · cited 1×
“We used XenofilteR, an R-package to separate mouse reads from the aligned human sequence reads (29).”
MethodSelf-citationPatient‐derived xenografts for individualized care in advanced sarcoma
Stebbing, J., Paz, K., Schwartz, G. K., Wexler, L. H., Maki, R., Pollock, R. E., Morris, R., Cohen, R., Shankar, A., Blackman, G., et al. (2014) · Cancer · doi:10.1002/cncr.28696 · Cited by 156 · cited 1×
“Defining features of this 405 microfluidic system are: (1) relatively large (tumor) tissue slices can be loaded, (2) flow of culture media 406 both above and under the tissue slice to sustain constant delivery of nutrients and gasses and removal of 407 waste products, (3) mainly silicon-based components, (4) standard…”
BackgroundTumor slice culture system to assess drug response of primary breast cancer
Naipal, K. A. T., Verkaik, N. S., Sánchez, H., van Deurzen, C. H. M., den Bakker, M. A., Hoeijmakers, J. H. J., Kanaar, R., Vreeswijk, M. P. G., Jager, A., & van Gent, D. C. (2016) · BMC Cancer · doi:10.1186/s12885-016-2119-2 · Cited by 155 · cited 5×
“EdU (3mg/mL; Invitrogen) was added to the culture medium 2 hours before formalin fixation and its incorporationwas analyzed as described previously (8).”
BackgroundMethodInfluentialSelf-citationShirure, V. S., & George, S. C. (2017) · Lab on a Chip · doi:10.1039/c6lc01401a · Cited by 135 · cited 1×
“This is especially 419 important when using PDMS-based devices and hydrophobic compounds (47).”
BackgroundPisano, M., Triacca, V., Barbee, K. A., & Swartz, M. A. (2015) · Integrative Biology · doi:10.1039/c5ib00085h · Cited by 114 · cited 1×
“The highest shear stress experienced by the tissue would be very low (~10-5 dyn/cm2), even below 311 physiological shear stresses detected in lymphatic capillaries (41).”
BackgroundShim, S., Belanger, M. C., Harris, A. R., Munson, J. M., & Pompano, R. R. (2019) · Lab on a Chip · doi:10.1039/c8lc00957k · Cited by 108 · cited 2×
“The tissue slice was modelled as a porous material with permeability 3 x 10-12 m2 (38).”
BackgroundMethodTumor-on-a-chip: a microfluidic model to study cell response to environmental gradients
Ayuso, J. M., Virumbrales-Munoz, M., McMinn, P. H., Rehman, S., Gomez, I., Karim, M. R., Trusttchel, R., Wisinski, K. B., Beebe, D. J., & Skala, M. C. (2019) · Lab on a Chip · doi:10.1039/c9lc00270g · Cited by 100
Verhaegh, W., van Ooijen, H., Inda, M. A., Hatzis, P., Versteeg, R., Smid, M., Martens, J., Foekens, J., van de Wiel, P., Clevers, H., et al. (2014) · Cancer Research · doi:10.1158/0008-5472.can-13-2515 · Cited by 92
Navone, N. M., van Weerden, W. M., Vessella, R. L., Williams, E. D., Wang, Y. Z., Isaacs, J. T., Nguyen, H. M., Čulig, Z., van der Pluijm, G., Rentsch, C. A., et al. (2018) · The Prostate · doi:10.1002/pros.23701 · Cited by 91
Holliday, D. L., Brouilette, K. T., Markert, A., Gordon, L. A., & Jones, J. L. (2009) · Breast Cancer Research · doi:10.1186/bcr2218 · Cited by 88
Multiplexed drug testing of tumor slices using a microfluidic platform
Horowitz, L. F., Rodriguez, A. D., Dereli-Korkut, Z., Lin, R., Castro, K., Mikheev, A. M., Monnat, R. J., Folch, A., & Rostomily, R. C. (2020) · npj Precision Oncology · doi:10.1038/s41698-020-0117-y · Cited by 88 · cited 1×
“Previously published similar systems either use only bottom flow (17, 44-46) or perfusion through 415 the slice (19, 21).”
MethodParallel microfluidic chemosensitivity testing on individual slice cultures
Chang, T. C., Mikheev, A. M., Huynh, W., Monnat, R. J., Rostomily, R. C., & Folch, A. (2014) · Lab Chip · doi:10.1039/c4lc00642a · Cited by 85 · cited 1×
“Previously published similar systems either use only bottom flow (17, 44-46) or perfusion through 415 the slice (19, 21).”
MethodA microfluidic platform for functional testing of cancer drugs on intact tumor slices
Rodriguez, A. D., Horowitz, L. F., Castro, K., Kenerson, H., Bhattacharjee, N., Gandhe, G., Raman, A., Monnat, R. J., Yeung, R., Rostomily, R. C., et al. (2020) · Lab on a Chip · doi:10.1039/c9lc00811j · Cited by 77
Meijer, T. G., Verkaik, N. S., Sieuwerts, A. M., van Riet, J., Naipal, K. A. T., van Deurzen, C. H. M., den Bakker, M. A., Sleddens, H. F. B. M., Dubbink, H.-J., den Toom, T. D., et al. (2018) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-18-0063 · Cited by 67 · cited 2×
“213 TUNEL, EdU and DAPI images were analyzed automatically using previously published methods (11).”
BackgroundMethodSelf-citationMartin, S. Z., Wagner, D., Hörner, N., Horst, D. A., Lang, H., Tagscherer, K. E., & Roth, W. (2019) · BMC Cancer · doi:10.1186/s12885-019-6270-4 · Cited by 61
Kennedy, R., Kuvshinov, D., Sdrolia, A., Kuvshinova, E., Hilton, K., Crank, S., Beavis, A. W., Green, V., & Greenman, J. (2019) · Scientific Reports · doi:10.1038/s41598-019-42745-2 · Cited by 60 · cited 1×
“Previously published similar systems either used only bottom flow (16, 43–45) or perfusion through the slice (18, 20).”
Methodde Inda, M. A., Blok, E. J., Kuppen, P. J. K., Charehbili, A., den Biezen, E., van Brussel, A., Fruytier, S. E., Kranenbarg, E. M., Kloet, S. L., van der Burg, B., et al. (2020) · Molecular Cancer Therapeutics · doi:10.1158/1535-7163.mct-19-0318 · Cited by 58
Hattersley, S. M., Sylvester, D. C., Dyer, C. E., Stafford, N. D., Haswell, S. J., & Greenman, J. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0428-9 · Cited by 55 · cited 1×
“Previously published similar systems either use only bottom flow (17, 44-46) or perfusion through 415 the slice (19, 21).”
MethodDíaz, A., & Jiménez, S. A. (1997) · The International Journal of Biochemistry & Cell Biology · doi:10.1016/s1357-2725(96)00112-4 · Cited by 54 · cited 1×
“In line with 389 these findings, gene expression analysis of mouse stromal genes showed downregulation of collagen 390 genes (Col3a1, Col6a2, Col15a1) in the ex vivo culture (Supplementary table S3), which is a known effect 391 of interferon-gamma (IFN-γ) signaling (43).”
BackgroundCytostretch, an Organ-on-Chip Platform
Gaio, N., Van Meer, B., Quirós Solano, W., Bergers, L., Van de Stolpe, A., Mummery, C., Sarro, P., & Dekker, R. (2016) · Micromachines · doi:10.3390/mi7070120 · Cited by 50 · cited 1×
“Furthermore, the CoC 429 device presented here is an evolution of the Cytostretch platform that can be equipped with electrodes and 430 other sensors to allow real time measurement of additional parameters, such as oxygen, pH and 431 temperature (48,49).”
MethodSelf-citationRiley, A., Green, V., Cheah, R., McKenzie, G., Karsai, L., England, J. A., & Greenman, J. (2019) · BMC Cancer · doi:10.1186/s12885-019-5465-z · Cited by 50
Ex vivo treatment of prostate tumor tissue recapitulates in vivo therapy response
Zhang, W., van Weerden, W. M., de Ridder, C. M. A., Erkens‐Schulze, S., Schönfeld, E., Meijer, T. G., Kanaar, R., van Gent, D. C., & Nonnekens, J. (2018) · The Prostate · doi:10.1002/pros.23745 · Cited by 45
Self-citationQuantitative Measurement of Functional Activity of the PI3K Signaling Pathway in Cancer
van de Stolpe, A. (2019) · Cancers · doi:10.3390/cancers11030293 · Cited by 40
Ponte, R. M. D., Gaio, N., van Zeijl, H. W., Vollebregt, S., Dijkstra, P., Dekker, R. H., Serdijn, W. A., & Giagka, V. (2020) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2020.112439 · Cited by 39 · cited 1×
“Furthermore, the CoC device presented here is an evolution of the Cytostretch platform that can be equipped with electrodes and other sensors to allow real time measurement of additional parameters, such as oxygen, pH, and temperature (47, 48).”
MethodSelf-citationInterplay of SMARCAD1 and BRCA1 at Replication Forks to Maintain Genome Integrity
Lo, C. S. Y., van Toorn, M., Gaggioli, V., Dias, M. P., Zhu, Y., Manolika, E. M., Zhao, W., van der Does, M., Mukherjee, C., Gonçalves, J. G. S. C. S., et al. (2020) · Science Advances · doi:10.1126/sciadv.abe7804 · Cited by 38 · cited 2×
“The analysis of the imaging data has been conducted using customized 217 pipelines in Cell Profiler (25).”
MethodSelf-citationPermeation of Water through Hydrogels with Controlled Network Structure
Fujiyabu, T., Li, X., Shibayama, M., Chung, U., & Sakai, T. (2017) · Macromolecules · doi:10.1021/acs.macromol.7b01807 · Cited by 36
Muruganandan, S., Fan, X., Dhal, S., & Nayak, N. R. (2020) · Biomolecules · doi:10.3390/biom10010136 · Cited by 33
A Molecular Test for Quantifying Functional Notch Signaling Pathway Activity in Human Cancer
Canté-Barrett, K., Holtzer, L., van Ooijen, H., Hagelaar, R., Cordo’, V., Verhaegh, W., van de Stolpe, A., & Meijerink, J. P. P. (2020) · Cancers · doi:10.3390/cancers12113142 · Cited by 27 · cited 1×
“Functional activity of the estrogen receptor (ER), AR, PI3K, and MAPK growth factor pathways, Hedgehog (HH), Notch, and TGFb cell signaling pathways was measured using qRT-PCR–based pathway analysis tests using FFPE derived RNA from each breast PDX tumor group cultured in ex vivo and CoC platform (33).”
MethodExamination of ex-vivo viability of human adipose tissue slice culture
Schopow, N., Kallendrusch, S., Gong, S., Rapp, F., Körfer, J., Gericke, M. T., Spindler, N., Josten, C., Langer, S., & Bechmann, I. (2020) · PLoS ONE · doi:10.1371/journal.pone.0233152 · Cited by 25
Zhang, W., Liao, C., Chtatou, H., Incrocci, L., van Gent, D. C., van Weerden, W. M., & Nonnekens, J. (2019) · Cancers · doi:10.3390/cancers11101593 · Cited by 23 · cited 1×
“To assess DNA damage repair, 53BP1 (anti rabbit, 1/1000, 233 Novus Biologicals) staining was performed in PDX tumor tissue slices treated with cisplatin as described 234 previously (26).”
MethodZhang, Y., Wang, L., Gao, P., Sun, Z., Li, N., Lu, Y., Shen, J., Sun, J., Yang, Y., Dai, H., et al. (2018) · International Journal of Molecular Medicine · doi:10.3892/ijmm.2018.3842 · Cited by 22 · cited 1×
“Defining features of this 405 microfluidic system are: (1) relatively large (tumor) tissue slices can be loaded, (2) flow of culture media 406 both above and under the tissue slice to sustain constant delivery of nutrients and gasses and removal of 407 waste products, (3) mainly silicon-based components, (4) standard…”
Backgroundvan Weerden, W. M., van Steenbrugge, G. J., van Kreuningen, A., Moerings, E. P. C. M., de Jong, F. H., & Schröder, F. H. (1991) · The Journal of Urology · doi:10.1016/s0022-5347(17)38409-4 · Cited by 20 · cited 1×
“We found significantly reduced AR expression, increased TUNEL positive cells and 342 a significant decrease in EdU positive cells after apalutamide exposure, very similar to the effect of 343 antiandrogen treatment in vivo (42) and in ex vivo cultures (Fig.”
Result
Cited by
Cancer organoids 2.0: modelling the complexity of the tumour immune microenvironment
Polak, R., Zhang, E. T., & Kuo, C. J. (2024) · Nature Reviews Cancer · doi:10.1038/s41568-024-00706-6 · Cited by 298
Organ-on-a-chip meets artificial intelligence in drug evaluation
Deng, S., Li, C., Cao, J., Cui, Z., Du, J., Fu, Z., Yang, H., & Chen, P. (2023) · Theranostics · doi:10.7150/thno.87266 · Cited by 260
“At present, tumor OoCs also include colorectal [55, 140], ovarian [141, 142], prostate [143, 144], bladder [145, 146], cervical [147, 148], gastric [56, 149], and skin [150, 151] cancer.”
BackgroundDrug screening on digital microfluidics for cancer precision medicine
Zhai, J., Liu, Y., Ji, W., Huang, X., Wang, P., Li, Y., Li, H., Wong, A. H., Zhou, X., Chen, P., et al. (2024) · Nature Communications · doi:10.1038/s41467-024-48616-3 · Cited by 133
“Another approach to observe the primary tumor cell responses to drug involved the use of a thin slice of tumor which already has the same microenvironment as an in-vivo tumor 59,67 .”
Breakthroughs and Applications of Organ-on-a-Chip Technology
Koyilot, M. C., Natarajan, P., Hunt, C. R., Sivarajkumar, S., Roy, R., Joglekar, S. S., Pandita, S., Tong, C. W.-C., Marakkar, S., Subramanian, L., et al. (2022) · Cells · doi:10.3390/cells11111828 · Cited by 117
Creating a kidney organoid-vasculature interaction model using a novel organ-on-chip system
Menéndez, A. B.-C., Du, Z., van den Bosch, T. P. P., Othman, A., Gaio, N., Silvestri, C., Quirós-Solano, W. F., Lin, H., Korevaar, S. S., Merino, A. M., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-24945-5 · Cited by 82
Self-citation
Metadata
- Authors
- Chakrabarty, S., Quiros-Solano, W. F., Kuijten, M. M. P., Haspels, B., Mallya, S., Lo, C. S. Y., Othman, A., Silvestri, C., van de Stolpe, A., Gaio, N., Odijk, H., van de Ven, M., de Ridder, C. M. A., van Weerden, W. M., Jonkers, J., Dekker, R., Taneja, N., Kanaar, R., & van Gent, D. C.
- Affiliations
- Manipal Academy of Higher Education (IN)
- 3Department of Microelectronics, Electronic Components, Technology and Materials, Delft University of Technology, Delft, the Netherlands.
- Erasmus MC (NL)
- 4BIOND Solutions B.V., Delft, the Netherlands.
- 7Philips Research, Eindhoven, the Netherlands.
- 8Preclinical Intervention Unit, Mouse Clinic for Cancer and Ageing, The Netherlands Cancer Institute, Amsterdam, the Netherlands.
- 9Department of Urology, Erasmus MC Cancer Institute, Erasmus University Medical Center, Rotterdam, the Netherlands.
- The Netherlands Cancer Institute (NL)
- Delft University of Technology (NL)
- 1Department of Molecular Genetics, Erasmus MC Cancer Institute, Erasmus University Medical Center, Rotterdam, the Netherlands.
- ORCID
- Venue
- Cancer Research
- Published
- 2021-12-06
- Volume
- 82
- Issue
- 3
- Pages
- 510-520
- ISSN
- 0008-5472 (ISSN-L)
- 1538-7445
- PMC
- PMC9397621
- OpenAlex
- W4200376156
- Semantic Scholar
- 83aabd9100f0593fac2ff85c353c9ed6d4eb1117
- Cited by
- 61
- References
- 52
- Citations by year
- 2026: 15 · 2025: 14 · 2024: 12 · 2023: 13 · 2022: 7
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Cancer Research (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- EUR Research Repository (Erasmus University Rotterdam) (publishedVersion, cc-by-nc-nd)
- EUR Research Repository (Erasmus University Rotterdam) (submittedVersion, other-oa)
- Research Repository (Delft University of Technology) (submittedVersion, cc-by-nc-nd)
- Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
- Funders
- KWF Kankerbestrijding (KWF11011)
- Nederlandse Organisatie voor Wetenschappelijk Onderzoek (737.016.011)
- Electronic Components and Systems for European Leadership (H2020-ECSEL-2019-IA-876190)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Health Sciences › Medicine › Oncology › Cancer Cells and Metastasis
- Keywords
- drug response prediction, microfluidic platform, breast cancer, prostate cancer, cisplatin, apalutamide, chemosensitivity, xenograft models, personalized treatment, silicon microfluidics, primary tumor tissue
- MeSH terms
- Humans, Organ Culture Techniques, Gene Expression, Microfluidics, Biomarkers, Pharmacological
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.