Affibody Molecules for In vivo Characterization of HER2-Positive Tumors by Near-Infrared Imaging
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Purpose: HER2 overexpression has been associated with a poor prognosis and resistance to therapy in breast cancer patients. We are developing molecular probes for in vivo quantitative imaging of HER2 receptors using near-infrared (NIR) optical imaging. The goal is to provide probes that will minimally interfere with the studied system, that is, whose binding does not interfere with the binding of the therapeutic agents and whose effect on the target cells is minimal. Experimental Design: We used three different types of HER2-specific Affibody molecules [monomer ZHER2:342, dimer (ZHER2:477)2, and albumin-binding domain-fused-(ZHER2:342)2] as targeting agents and labeled them with Alexa Fluor dyes. Trastuzumab was also conjugated, using commercially available kits, as a standard control. The resulting conjugates were characterized in vitro by toxicity assays, Biacore affinity measurements, flow cytometry, and confocal microscopy. Semiquantitative in vivo NIR optical imaging studies were carried out using mice with s.c. xenografts of HER2-positive tumors. Results: The HER2-specific Affibody molecules were not toxic to HER2-overexpressing cells and their binding to HER2 did interfere with neither binding nor effectives of trastuzumab. The binding affinities and specificities of the Affibody-Alexa Fluor fluorescent conjugates to HER2 were unchanged or minimally affected by the modifications. Pharmacokinetics and biodistribution studies showed the albumin-binding domain-fused-(ZHER2:342)2-Alexa Fluor 750 conjugate to be an optimal probe for optical imaging of HER2 in vivo. Conclusion: Our results suggest that Affibody-Alexa Fluor conjugates may be used as a specific NIR probe for the noninvasive semiquantitative imaging of HER2 expression in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Slamon, D. J., Clark, G. M., Wong, S. G., Levin, W. J., Ullrich, A., & McGuire, W. L. (1987) · Science · doi:10.1126/science.3798106 · Cited by 11,760
ERBB receptors and cancer: the complexity of targeted inhibitors
Hynes, N. E., & Lane, H. A. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1609 · Cited by 3,313
A guide to choosing fluorescent proteins
Shaner, N. C., Steinbach, P. A., & Tsien, R. Y. (2005) · Nature Methods · doi:10.1038/nmeth819 · Cited by 2,840 · cited 1×
“It allows visualization of subcellular structures on a microscopic scale, even in vivo, and the macroscopic distribution of fluorescent labels in small animals (18, 19 ).”
BackgroundIn vivo near-infrared fluorescence imaging
Frangioni, J. V. (2003) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.08.007 · Cited by 2,653 · cited 2×
“Imaging agents based on those molecules will have a high affinity for HER2 and a smaller size compared with antibodies ( 20 ) or antibody fragments (4) and therefore should provide better results than the currently tested conjugates (15, 16).”
BackgroundResultMonoclonal antibody therapy of cancer
Adams, G. P., & Weiner, L. M. (2005) · Nature Biotechnology · doi:10.1038/nbt1137 · Cited by 1,246
Mechanisms of Disease: understanding resistance to HER2-targeted therapy in human breast cancer
Nahta, R., Yu, D., Hung, M.-C., Hortobagyi, G. N., & Esteva, F. J. (2006) · Nature Clinical Practice Oncology · doi:10.1038/ncponc0509 · Cited by 916
Konecny, G. E., Pegram, M. D., Venkatesan, N., Finn, R., Yang, G., Rahmeh, M., Untch, M., Rusnak, D. W., Spehar, G., Mullin, R. J., et al. (2006) · Cancer Research · doi:10.1158/0008-5472.can-05-1182 · Cited by 914
Concurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement
Ntziachristos, V., Yodh, A. G., Schnall, M., & Chance, B. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040570597 · Cited by 793
The multiple uses of fluorescent proteins to visualize cancer in vivo
Hoffman, R. M. (2005) · Nature Reviews Cancer · doi:10.1038/nrc1717 · Cited by 617
Expression of the HER1–4 family of receptor tyrosine kinases in breast cancer
Witton, C. J., Reeves, J. R., Going, J. J., Cooke, T. G., & Bartlett, J. M. (2003) · The Journal of Pathology · doi:10.1002/path.1370 · Cited by 590
Tumor Imaging Using a Picomolar Affinity HER2 Binding Affibody Molecule
Orlova, A., Magnusson, M., Eriksson, T. L. J., Nilsson, M., Larsson, B., Höidén-Guthenberg, I., Widström, C., Carlsson, J., Tolmachev, V., Ståhl, S., et al. (2006) · Cancer Research · doi:10.1158/0008-5472.can-05-3521 · Cited by 568
Molecular Imaging: Looking at Problems, Seeing Solutions
Herschman, H. R. (2003) · Science · doi:10.1126/science.1090585 · Cited by 382 · cited 1×
“Thus, there is a need for molecular probes to monitor in vivo the receptor downregulation as an immediate response to these therapies because the current ex vivo analyses of tumor tissues obtained by surgery or biopsy from breast cancer patients are not always representative (7, 8). Molecular imaging using these probe…”
BackgroundAnalyzing a kinetic titration series using affinity biosensors
Karlsson, R., Katsamba, P. S., Nordin, H., Pol, E., & Myszka, D. G. (2006) · Analytical Biochemistry · doi:10.1016/j.ab.2005.09.034 · Cited by 382 · cited 1×
“A concentration series of ZHER2:342 were injected for 33 min over the HER2/FC capture surface at 5 AL/min ( 26 ).”
MethodStrategies for optimizing combinations of molecularly targeted anticancer agents
Dancey, J. E., & Chen, H. X. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd2089 · Cited by 365
Tada, H., Higuchi, H., Wanatabe, T. M., & Ohuchi, N. (2007) · Cancer Research · doi:10.1158/0008-5472.can-06-1185 · Cited by 352
Perik, P. J., Lub-De Hooge, M. N., Gietema, J. A., van der Graaf, W. T. A., de Korte, M. A., Jonkman, S., Kosterink, J. G. W., van Veldhuisen, D. J., Sleijfer, D. T., Jager, P. L., et al. (2006) · Journal of Clinical Oncology · doi:10.1200/jco.2005.03.8448 · Cited by 310 · cited 1×
“Imaging agents based on those molecules will have a high affinity for HER2 and a smaller size compared with antibodies (20) or antibody fragments (4) and therefore should provide better results than the currently tested conjugates ( 15 , 16).”
ResultImaging the pharmacodynamics of HER2 degradation in response to Hsp90 inhibitors
Smith-Jones, P. M., Solit, D. B., Akhurst, T., Afroze, F., Rosen, N., & Larson, S. M. (2004) · Nature Biotechnology · doi:10.1038/nbt968 · Cited by 304
Choe, R., Corlu, A., Lee, K., Durduran, T., Konecky, S. D., Grosicka‐Koptyra, M., Arridge, S. R., Czerniecki, B. J., Fraker, D. L., DeMichele, A., et al. (2005) · Medical Physics · doi:10.1118/1.1869612 · Cited by 295
Zidan, J., Dashkovsky, I., Stayerman, C., Basher, W., Cozacov, C., & Hadary, A. (2005) · British Journal of Cancer · doi:10.1038/sj.bjc.6602738 · Cited by 282
In vivo continuous‐wave optical breast imaging enhanced with Indocyanine Green
Intes, X., Ripoll, J., Chen, Y., Nioka, S., Yodh, A. G., & Chance, B. (2003) · Medical Physics · doi:10.1118/1.1573791 · Cited by 257
Imaging Tumors with an Albumin-Binding Fab, a Novel Tumor-Targeting Agent
Dennis, M. S., Jin, H., Dugger, D., Yang, R., McFarland, L., Ogasawara, A., Williams, S., Cole, M. J., Ross, S., & Schwall, R. (2007) · Cancer Research · doi:10.1158/0008-5472.can-06-2531 · Cited by 251 · cited 1×
“Fusion of the ABD to imaging probes has been successfully adopted to prolong the circulation half-life of the probes, including the HER2-specific Affibody molecule ( 45 , 46).”
MethodSelection and characterization of HER2/neu-binding affibody ligands
Wikman, M., Steffen, A.-C., Gunneriusson, E., Максимилианович, Т. В., Adams, G. P., Carlsson, J., & Ståhl, S. (2004) · Protein Engineering Design and Selection · doi:10.1093/protein/gzh053 · Cited by 246
Tolmachev, V., Orlova, A., Pehrson, R., Galli, J., Baastrup, B., Andersson, K., Sandström, M., Rosik, D., Carlsson, J., Lundqvist, H., et al. (2007) · Cancer Research · doi:10.1158/0008-5472.can-06-1630 · Cited by 220
Fluorescence Molecular Imaging of Small Animal Tumor Models
Graves, E., Weissleder, R., & Ntziachristos, V. (2004) · Current Molecular Medicine · doi:10.2174/1566524043360555 · Cited by 213 · cited 1×
“Although most of these studies are qualitative, quantitative methods are beginning to emerge ( 21 ).”
BackgroundOrlova, A., Tolmachev, V., Pehrson, R., Lindborg, M., Tran, T., Sandström, M., Nilsson, F. Y., Wennborg, A., Abrahmsén, L., & Feldwisch, J. (2007) · Cancer Research · doi:10.1158/0008-5472.can-06-2887 · Cited by 193
Tomographic Fluorescence Mapping of Tumor Targets
Montet, X., Ntziachristos, V., Grimm, J., & Weissleder, R. (2005) · Cancer Research · doi:10.1158/0008-5472.can-05-0382 · Cited by 175
Robinson, M. K., Doss, M., Shaller, C., Narayanan, D., Marks, J. D., Adler, L. P., González Trotter, D. E., & Adams, G. P. (2005) · Cancer Research · doi:10.1158/0008-5472.can-04-2008 · Cited by 169
Optimizing Radiolabeled Engineered Anti-p185HER2 Antibody Fragments for In vivo Imaging
Olafsen, T., Kenanova, V. E., Sundaresan, G., Anderson, A.-L., Crow, D., Yazaki, P. J., Li, L., Press, M. F., Gambhir, S. S., Williams, L. E., et al. (2005) · Cancer Research · doi:10.1158/0008-5472.can-04-4472 · Cited by 155
Time-Domain Optical Mammography SoftScan: Initial Results
Intes, X., Djeziri, S., Ichalalène, Z., Mincu, N. E., Wang, Y., St.-Jean, P., Lesage, F., Hall, D. J., Boas, D. A., Polyzos, M., et al. (2005) · Academic Radiology · doi:10.1016/j.acra.2005.08.029 · Cited by 150
Affibody molecules: potential forin vivoimaging of molecular targets for cancer therapy
Максимилианович, Т. В., Orlova, A., Nilsson, F. Y., Feldwisch, J., Wennborg, A., & Abrahmsén, L. (2007) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.7.4.555 · Cited by 143 · cited 1×
“Recently, several successful tumor imaging studies have been reported using radiolabeled HER2-specific Affibody molecules for imaging of HER2-expressing tumors ( 13 ).”
BackgroundTime-Domain Optical Mammography SoftScan
Intes, X. (2005) · Academic Radiology · doi:10.1016/j.acra.2005.05.006 · Cited by 134
Three-dimensional time-resolved optical mammography of the uncompressed breast
Enfield, L. C., Gibson, A. P., Everdell, N. L., Delpy, D. T., Schweiger, M. J., Arridge, S., Richardson, C., Keshtgar, M. R. S., Douek, M., & Hebden, J. C. (2007) · Applied Optics · doi:10.1364/ao.46.003628 · Cited by 111
Affibody molecules: new protein domains for molecular imaging and targeted tumor therapy.
Nilsson, F. Y., & Tolmachev, V. (2007) · PubMed · Cited by 107
Fluorescence Lifetime Imaging System for in Vivo Studies
Hassan, M., Riley, J., Chernomordik, V., Smith, P., Pursley, R. H., Lee, S. B., Capala, J., & Gandjbakhche Amir, H. (2007) · Molecular Imaging · doi:10.2310/7290.2007.00019 · Cited by 102
Self-citationLundberg, E. K., Höidén‐Guthenberg, I., Larsson, B., Uhlén, M., & Gräslund, T. (2006) · Journal of Immunological Methods · doi:10.1016/j.jim.2006.10.013 · Cited by 52
HER2 testing: a review of detection methodologies and their clinical performance
Laudadio, J., Quigley, D. I., Tubbs, R., & Wolff, D. J. (2006) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.7.1.53 · Cited by 42
Effects of HER2-Binding Affibody Molecules on Intracellular Signaling Pathways
Ekerljung, L., Steffen, A.-C., Carlsson, J., & Lennartsson, J. (2006) · Tumor Biology · doi:10.1159/000093023 · Cited by 27
Myszka, D. G. (1999) · Journal of Molecular Recognition · doi:10.1002/(sici)1099-1352(199909/10)12:5<279::aid-jmr473>3.0.co;2-3 · cited 1×
“These effects are often removed through a double referencing protocol ( 27 ).”
Background
Cited by
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Impact of albumin on drug delivery — New applications on the horizon
Elsadek, B., & Kratz, F. (2012) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.09.069 · Cited by 832
Löfblom, J., Feldwisch, J., Tolmachev, V., Carlsson, J., Ståhl, S., & Frejd, F. Y. (2010) · FEBS Letters · doi:10.1016/j.febslet.2010.04.014 · Cited by 651
The role of HER2 in cancer therapy and targeted drug delivery
Tai, W., Mahato, R., & Cheng, K. (2010) · Journal of Controlled Release · doi:10.1016/j.jconrel.2010.04.009 · Cited by 555
Epidermal growth factor receptor targeting in cancer: a review of trends and strategies
Yewale, C., Baradia, D., Vhora, I., Patil, S., & Misra, A. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.100 · Cited by 533
Metadata
- Authors
- Lee, S. B., Hassan, M., Fisher, R., Chertov, O., Chernomordik, V., Kramer-Marek, G., Gandjbakhche, A., & Capala, J.
- Venue
- Clinical Cancer Research
- Published
- 2008-06-15
- Volume
- 14
- Issue
- 12
- Pages
- 3840-3849
- ISSN
- 1078-0432 (ISSN-L)
- 1557-3265
- OpenAlex
- W2131443651
- Cited by
- 171
- References
- 38
- FWCI
- 14.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.