The DOI matches its Crossref record.
Determination of the Horny Layer Profile by Tape Stripping in Combination with Optical Spectroscopy in the Visible Range as a Prerequisite to Quantify Percutaneous Absorption
Abstract
A new method was developed to determine the horny layer profile of volunteers using tape stripping in combination with UV/visible spectroscopy. The optical absorbance and the weight of corneocyte aggregates were compared as parameters for the determination of the mass of the horny layer particles fixed to the individual tapes. It was shown that the potential disturbances influencing both parameters must be considered critically before calculating the correlation factor, found as R 2mean = 0.93 ± 0.05. It was proven that the absorbance in the visible range is better suited than the weight to quantify the amount of corneocyte aggregates removed by a single strip. The new method allows an exact anatomical localization of the individual tapes and all data obtained within the depth profile of the stratum corneum. This was exemplified by the determination of the penetration of chemical and physical UV filters into the horny layer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Grey Goo on the Skin? Nanotechnology, Cosmetic and Sunscreen Safety
Nohynek, G. J., Lademann, J., Ribaud, C., & Roberts, M. S. (2007) · Critical Reviews in Toxicology · doi:10.1080/10408440601177780 · Cited by 644
Self-citationLipid nanoparticles for improved topical application of drugs for skin diseases☆
SCHAFERKORTING, M., MEHNERT, W., & KORTING, H. (2007) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2007.04.006 · Cited by 614
Nanoparticles – An efficient carrier for drug delivery into the hair follicles
Lademann, J., Richter, H., Teichmann, A., Otberg, N., Blume-Peytavi, U., Luengo, J., Weiß, B., Schaefer, U. F., Lehr, C.-M., & Wepf, R. (2007) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2006.10.019 · Cited by 573
Self-citationLademann, J., Weigmann, H.-J., Rickmeyer, C., Barthelmes, H., Schaefer, H., Mueller, G., & Sterry, W. (1999) · Skin Pharmacology and Physiology · doi:10.1159/000066249 · Cited by 527
Self-citationWeerheim, A., & Ponec, M. (2001) · Archives of Dermatological Research · doi:10.1007/s004030100212 · Cited by 302
Metadata
- Authors
- Weigmann, H.-J., Lademann, J., Meffert, H., Schaefer, H., & Sterry, W.
- Venue
- Skin Pharmacology and Physiology
- Publisher
- S. Karger AG
- Published
- 1999
- Volume
- 12
- Issue
- 1-2
- Pages
- 34-45
- ISSN
- 1422-2868 (ISSN-L)
- 1660-5527
- 1660-5535
- OpenAlex
- W1999140583
- Cited by
- 169
- References
- 0
- FWCI
- 4.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of the Horny Layer Profile by Tape Stripping in Combination with Optical Spectroscopy in the Visible Range as a Prerequisite to Quantify Percutaneous Absorption. https://app.cochat.ai/papers/10.1159/000029844
- The paper
- Weigmann, H.-J., Lademann, J., Meffert, H., Schaefer, H., & Sterry, W. (1999). Determination of the Horny Layer Profile by Tape Stripping in Combination with Optical Spectroscopy in the Visible Range as a Prerequisite to Quantify Percutaneous Absorption. Skin Pharmacology and Physiology. https://doi.org/10.1159/000029844
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.