Development of a Completely Encapsulated Intraocular Pressure Sensor
The DOI matches its Crossref record.
Abstract
A completely encapsulated intraocular pressure (IOP) sensor equipped with telemetric signal and energy transfer is introduced integrated into a silicone disc for implantation into the eye. After implantation into enucleated pig eyes and into rabbit eyes in vivo, the IOP was recorded and compared to established techniques of IOP measurement. Pressure chamber tests showed that the sensor functioned correctly after biocompatible encapsulation in polydimethylsiloxane. In vivo and in vitro tests in rabbit and pig eyes demonstrated that the implanted system worked with the same precision as established techniques for IOP determination. The correlation between the measurements with the implanted device and pneumotonometry in several experiments was between 0.9 and 0.99. This device serves as a functioning model for the realization of a telemetric IOP sensor for integration into an artificial intraocular lens. Such a device will open new perspectives, not only in the management of glaucoma, but also in basic research for mechanisms of glaucoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
Leonardi, M., Pitchon, E. M., Bertsch, A., Renaud, P., & Mermoud, A. (2009) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2008.01404.x · Cited by 300
“Because standard clinic follow-up evaluations fail to identify peaks and IOP variations, many attempts to find a practical and portable solution for IOP monitoring have been made in the past, without success (Maurice 1958; Collins 1967; Greene & Gilman 1974; Couvillon et al. 1976; Nissen 1977; Cooper et al. 1979; Wolb…”
BackgroundFirst steps toward noninvasive intraocular pressure monitoring with a sensing contact lens
Leonardi, M., Leuenberger, P., Bertrand, D., Bertsch, A., & Renaud, P. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0015 · Cited by 244
Mansouri, K., & Shaarawy, T. (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.192922 · Cited by 232
Assessment of True Intraocular Pressure: The Gap Between Theory and Practical Data
Chihara, E. (2008) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2008.02.005 · Cited by 180
Cavitas Sensors: Contact Lens Type Sensors & Mouthguard Sensors
Mitsubayashi, K., & Arakawa, T. (2016) · Electroanalysis · doi:10.1002/elan.201600083 · Cited by 71
Metadata
- Authors
- Walter, P., Schnakenberg, U., vom Bögel, G., Ruokonen, P., Krüger, C., Dinslage, S., Lüdtke Handjery, H. C., Richter, H., Mokwa, W., Diestelhorst, M., & Krieglstein, G. K.
- Venue
- Ophthalmic Research
- Publisher
- S. Karger AG
- Published
- 2000
- Volume
- 32
- Issue
- 6
- Pages
- 278-284
- ISSN
- 0030-3747 (ISSN-L)
- 1423-0259
- OpenAlex
- W1993827786
- Cited by
- 68
- References
- 0
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Development of a Completely Encapsulated Intraocular Pressure Sensor. https://app.cochat.ai/papers/10.1159/000055626
- The paper
- Walter, P., Schnakenberg, U., vom Bögel, G., Ruokonen, P., Krüger, C., Dinslage, S., Lüdtke Handjery, H. C., Richter, H., Mokwa, W., Diestelhorst, M., & Krieglstein, G. K. (2000). Development of a Completely Encapsulated Intraocular Pressure Sensor. Ophthalmic Research. https://doi.org/10.1159/000055626
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.