The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
An E-Health Solution for Automatic Sleep Classification according to Rechtschaffen and Kales: Validation Study of the Somnolyzer 24 × 7 Utilizing the Siesta Database
Abstract
To date, the only standard for the classification of sleep-EEG recordings that has found worldwide acceptance are the rules published in 1968 by Rechtschaffen and Kales. Even though several attempts have been made to automate the classification process, so far no method has been published that has proven its validity in a study including a sufficiently large number of controls and patients of all adult age ranges. The present paper describes the development and optimization of an automatic classification system that is based on one central EEG channel, two EOG channels and one chin EMG channel. It adheres to the decision rules for visual scoring as closely as possible and includes a structured quality control procedure by a human expert. The final system (Somnolyzer 24 × 7™) consists of a raw data quality check, a feature extraction algorithm (density and intensity of sleep/wake-related patterns such as sleep spindles, delta waves, SEMs and REMs), a feature matrix plausibility check, a classifier designed as an expert system, a rule-based smoothing procedure for the start and the end of stages REM, and finally a statistical comparison to age- and sex-matched normal healthy controls (Siesta Spot Report™). The expert system considers different prior probabilities of stage changes depending on the preceding sleep stage, the occurrence of a movement arousal and the position of the epoch within the NREM/REM sleep cycles. Moreover, results obtained with and without using the chin EMG signal are combined. The Siesta polysomnographic database (590 recordings in both normal healthy subjects aged 20–95 years and patients suffering from organic or nonorganic sleep disorders) was split into two halves, which were randomly assigned to a training and a validation set, respectively. The final validation revealed an overall epoch-by-epoch agreement of 80% (Cohen’s kappa: 0.72) between the Somnolyzer 24 × 7 and the human expert scoring, as compared with an inter-rater reliability of 77% (Cohen’s kappa: 0.68) between two human experts scoring the same dataset. Two Somnolyzer 24 × 7 analyses (including a structured quality control by two human experts) revealed an inter-rater reliability close to 1 (Cohen’s kappa: 0.991), which confirmed that the variability induced by the quality control procedure, whereby approximately 1% of the epochs (in 9.5% of the recordings) are changed, can definitely be neglected. Thus, the validation study proved the high reliability and validity of the Somnolyzer 24 × 7 and demonstrated its applicability in clinical routine and sleep studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 12,638
Introduction to Bayesian Networks
(2019) · Operational Risk Modelling in Financial Services · doi:10.1002/9781119508557.ch12 · Cited by 2,569
Analysis of a sleep-dependent neuronal feedback loop: the slow-wave microcontinuity of the EEG
Kemp, B., Zwinderman, A. H., Tuk, B., Kamphuisen, H. A. C., & Oberye, J. J. L. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.867928 · Cited by 953
Self-citationSLEEP COMPUTING COMMITTEE OF THE JAPANESE SOCIETY OF SLEEP RESEARCH SOCIETY (JSSR):, Hori, T., Sugita, Y., Koga, E., Shirakawa, S., Inoue, K., Uchida, S., Kuwahara, H., Kousaka, M., Kobayashi, T., et al. (2001) · Psychiatry and Clinical Neurosciences · doi:10.1046/j.1440-1819.2001.00810.x · Cited by 807
An Introduction to Bayesian Networks
Neil, M., & p, S. (2006) · Cited by 453
A simple format for exchange of digitized polygraphic recordings
Kemp, B., Värri, A., Rosa, A. C., Nielsen, K. D., & Gade, J. (1992) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(92)90009-7 · Cited by 370
Self-citationMonitoring and Staging Human Sleep
Carskadon, M. A., & Rechtschaffen, A. (2005) · Principles and Practice of Sleep Medicine · doi:10.1016/b0-72-160797-7/50123-3 · Cited by 267
Computer based sleep recording and analysis
Penzel, T., & Conradt, R. (2000) · Sleep Medicine Reviews · doi:10.1053/smrv.1999.0087 · Cited by 235
Self-citationComputer-assisted sleep staging
Agarwal, R., & Gotman, J. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.966600 · Cited by 219
Danker‐Hopfe, H., Kunz, D., Gruber, G., Klösch, G., Lorenzo, J. L., Himanen, S. L., Kemp, B., Penzel, T., Röschke, J., Dorn, H., et al. (2004) · Journal of Sleep Research · doi:10.1046/j.1365-2869.2003.00375.x · Cited by 217
Self-citation
Cited by
Sleep spindles: mechanisms and functions
Fernandez, L. M. J., & Lüthi, A. (2020) · Physiological Reviews · doi:10.1152/physrev.00042.2018 · Cited by 716
Fraiwan, L., Lweesy, K., Khasawneh, N., Wenz, H., & Dickhaus, H. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2011.11.005 · Cited by 432
Characterization of four-class motor imagery EEG data for the BCI-competition 2005
Schlögl, A., Lee, F., Bischof, H., & Pfurtscheller, G. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/l02 · Cited by 414
Self-citationNeural network analysis of sleep stages enables efficient diagnosis of narcolepsy
Stephansen, J. B., Olesen, A. N., Olsen, M., Ambati, A., Leary, E. B., Moore, H. E., Carrillo, O., Lin, L., Han, F., Yan, H., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-07229-3 · Cited by 413
Moser, D., Anderer, P., Gruber, G., Parapatics, S., Loretz, E., Boeck, M., Kloesch, G., Heller, E., Schmidt, A., Danker-Hopfe, H., et al. (2009) · Sleep · doi:10.1093/sleep/32.2.139 · Cited by 396
Self-citationZhu, G., Li, Y., & Wen, P. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2303991 · Cited by 384
Warby, S. C., Wendt, S. L., Welinder, P., Munk, E. G. S., Carrillo, O., Sorensen, H. B. D., Jennum, P., Peppard, P. E., Perona, P., & Mignot, E. (2014) · Nature Methods · doi:10.1038/nmeth.2855 · Cited by 383
Dworak, M., Schierl, T., Bruns, T., & Strüder, H. K. (2007) · Pediatrics · doi:10.1542/peds.2007-0476 · Cited by 376
ISRUC-Sleep: A comprehensive public dataset for sleep researchers
Khalighi, S., Sousa, T., Santos, J. M., & Nunes, U. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2015.10.013 · Cited by 367
O'Reilly, C., Gosselin, N., Carrier, J., & Nielsen, T. (2014) · Journal of Sleep Research · doi:10.1111/jsr.12169 · Cited by 356
Liang, S.-F., Kuo, C.-E., Hu, Y.-H., Pan, Y.-H., & Wang, Y.-H. (2012) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2012.2187242 · Cited by 303
Automatic Analysis of Single-Channel Sleep EEG: Validation in Healthy Individuals
Berthomier, C., Drouot, X., Herman-Stoïca, M., Berthomier, P., Prado, J., Bokar-Thire, D., Benoit, O., Mattout, J., & d'Ortho, M.-P. (2007) · Sleep · doi:10.1093/sleep/30.11.1587 · Cited by 294
Expert-level sleep scoring with deep neural networks
Biswal, S., Sun, H., Goparaju, B., Westover, M. B., Sun, J., & Bianchi, M. T. (2018) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocy131 · Cited by 290
Automated sleep scoring: A review of the latest approaches
Fiorillo, L., Puiatti, A., Papandrea, M., Ratti, P.-L., Favaro, P., Roth, C., Bargiotas, P., Bassetti, C. L., & Faraci, F. D. (2019) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2019.07.007 · Cited by 284
Schabus, M., Hödlmoser, K., Gruber, G., Sauter, C., Anderer, P., Klösch, G., Parapatics, S., Saletu, B., Klimesch, W., & Zeitlhofer, J. (2006) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2006.04694.x · Cited by 261
Self-citationValidation of an automated wireless system to monitor sleep in healthy adults
SHAMBROOM, J. R., FÁBREGAS, S. E., & JOHNSTONE, J. (2012) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2011.00944.x · Cited by 216
Increased slow wave sleep and reduced stage 2 sleep in children depending on exercise intensity
Dworak, M., Wiater, A., Alfer, D., Stephan, E., Hollmann, W., & Strüder, H. K. (2008) · Sleep Medicine · doi:10.1016/j.sleep.2007.04.017 · Cited by 185
Is there a link between sleep changes and memory in Alzheimer's disease?
Rauchs, G., Schabus, M., Parapatics, S., Bertran, F., Clochon, P., Hot, P., Denise, P., Desgranges, B., Eustache, F., Gruber, G., et al. (2008) · NeuroReport · doi:10.1097/wnr.0b013e32830867c4 · Cited by 179
Self-citationInterindividual sleep spindle differences and their relation to learning-related enhancements
Schabus, M., Hoedlmoser, K., Pecherstorfer, T., Anderer, P., Gruber, G., Parapatics, S., Sauter, C., Kloesch, G., Klimesch, W., Saletu, B., et al. (2008) · Brain Research · doi:10.1016/j.brainres.2007.10.106 · Cited by 174
Self-citationAutomatic Human Sleep Stage Scoring Using Deep Neural Networks
Malafeev, A., Laptev, D., Bauer, S., Omlin, X., Wierzbicka, A., Wichniak, A., Jernajczyk, W., Riener, R., Buhmann, J., & Achermann, P. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00781 · Cited by 151
Slow Wave Sleep and REM Sleep Awakenings Do Not Affect Sleep Dependent Memory Consolidation
Genzel, L., Dresler, M., Wehrle, R., Grözinger, M., & Steiger, A. (2009) · Sleep · doi:10.1093/sleep/32.3.302 · Cited by 107
Self-citationAutomating sleep stage classification using wireless, wearable sensors
Boe, A. J., McGee Koch, L. L., O’Brien, M. K., Shawen, N., Rogers, J. A., Lieber, R. L., Reid, K. J., Zee, P. C., & Jayaraman, A. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0210-1 · Cited by 98
Age affects sleep microstructure more than sleep macrostructure
Schwarz, J. F. A., Åkerstedt, T., Lindberg, E., Gruber, G., Fischer, H., & Theorell‐Haglöw, J. (2017) · Journal of Sleep Research · doi:10.1111/jsr.12478 · Cited by 88
Self-citationSleep apnea: a review of diagnostic sensors, algorithms, and therapies
Shokoueinejad, M., Fernandez, C., Carroll, E., Wang, F., Levin, J., Rusk, S., Glattard, N., Mulchrone, A., Zhang, X., Xie, A., et al. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa6ec6 · Cited by 64
Automatic sleep classification according to Rechtschaffen and Kales
Anderer, P., Gruber, G., Parapatics, S., & Dorffner, G. (2007) · 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2007.4353209 · Cited by 21
Self-citation
Metadata
- Authors
- Anderer, P., Gruber, G., Parapatics, S., Woertz, M., Miazhynskaia, T., Klösch, G., Saletu, B., Zeitlhofer, J., Barbanoj, M. J., Danker-Hopfe, H., Himanen, S.-L., Kemp, B., Penzel, T., Grözinger, M., Kunz, D., Rappelsberger, P., Schlögl, A., & Dorffner, G.
- Venue
- Neuropsychobiology
- Publisher
- S. Karger AG
- Published
- 2005
- Volume
- 51
- Issue
- 3
- Pages
- 115-133
- ISSN
- 0302-282X (ISSN-L)
- 1423-0224
- OpenAlex
- W2095518456
- Cited by
- 284
- References
- 43
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.