Pharmacokinetic Study of Ferumoxytol: A New Iron Replacement Therapy in Normal Subjects and Hemodialysis Patients
The DOI matches its Crossref record.
Abstract
Background: Currently available intravenous iron preparations are not ideal, either because of safety concerns or dose limitations. We investigated the safety and pharmacokinetics of ferumoxytol, a new iron replacement therapy, in normal subjects and hemodialysis patients. Methods: In a randomized, double-blind, ascending-dose study in normal volunteers (n = 41), 6 subjects received placebo, and 8 subjects each received ferumoxytol, at 1, 2 or 4 mg iron/kg, injected at 60 mg iron/min. The remaining subjects received 4 mg iron/kg at injection rates of 90 (n = 3), 180 (n = 3) or 1,800 mg iron/min (n = 5). In the second, open-label, ascending-dose study, 20 hemodialysis patients received 125 or 250 mg of iron over 5 min. Results: In normal subjects, the blood half-life of ferumoxytol increased with increasing dose from 9.3 to 14.5 h (p < 0.05) but not with increasing rate of injection. The drug half-life in hemodialysis patients was similar to normal subjects. Ferumoxytol was not removed with hemodialysis. Serum iron (p < 0.001), transferrin saturation (p < 0.001) and ferritin increased in both populations. No serious adverse events were attributable to ferumoxytol. Conclusion: Ferumoxytol was well tolerated in this study. Its pharmacokinetic properties and simplicity of administration suggest that it will be an attractive form of iron replacement therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zanganeh, S., Hutter, G., Spitler, R., Lenkov, O., Mahmoudi, M., Shaw, A., Pajarinen, J. S., Nejadnik, H., Goodman, S., Moseley, M., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.168 · Cited by 1,647
Nanopharmaceuticals and Nanomedicines Currently on the Market: Challenges and Opportunities
Farjadian, F., Ghasemi, A., Gohari, O., Roointan, A., Karimi, M., & Hamblin, M. R. (2019) · Nanomedicine · doi:10.2217/nnm-2018-0120 · Cited by 664
A Review of Clinical Translation of Inorganic Nanoparticles
Anselmo, A. C., & Mitragotri, S. (2015) · The AAPS Journal · doi:10.1208/s12248-015-9780-2 · Cited by 509
Weinstein, J. S., Varallyay, C. G., Dosa, E., Gahramanov, S., Hamilton, B., Rooney, W. D., Muldoon, L. L., & Neuwelt, E. A. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2009.192 · Cited by 500
“Ferumoxytol has been tested as an iron supplement therapy in patients with renal failure up to the dose of 510 mg (Landry et al, 2005; Spinowitz et al, 2005).”
BackgroundCurrent and potential imaging applications of ferumoxytol for magnetic resonance imaging
Toth, G. B., Varallyay, C. G., Horvath, A., Bashir, M. R., Choyke, P. L., Daldrup-Link, H. E., Dosa, E., Finn, J. P., Gahramanov, S., Harisinghani, M., et al. (2017) · Kidney International · doi:10.1016/j.kint.2016.12.037 · Cited by 317
Metadata
- Authors
- Landry, R., Jacobs, P. M., Davis, R., Shenouda, M., & Bolton, W. K.
- Venue
- American Journal of Nephrology
- Publisher
- S. Karger AG
- Published
- 2005
- Volume
- 25
- Issue
- 4
- Pages
- 400-410
- ISSN
- 0250-8095 (ISSN-L)
- 1421-9670
- OpenAlex
- W2083784395
- Cited by
- 108
- References
- 0
- FWCI
- 1.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pharmacokinetic Study of Ferumoxytol: A New Iron Replacement Therapy in Normal Subjects and Hemodialysis Patients. https://app.cochat.ai/papers/10.1159/000087212
- The paper
- Landry, R., Jacobs, P. M., Davis, R., Shenouda, M., & Bolton, W. K. (2005). Pharmacokinetic Study of Ferumoxytol: A New Iron Replacement Therapy in Normal Subjects and Hemodialysis Patients. American Journal of Nephrology. https://doi.org/10.1159/000087212
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.