CoChat

Location Not Quantity of Blood Pressure Measurements Predicts Mortality in Hemodialysis Patients

Open access
Agarwal, Rajiv, Andersen, Martin J., Light, Robert P. · 2008 · American Journal of Nephrology
Cited by 80

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

Background: Blood pressure (BP) measurements obtained outside the dialysis unit are prognostically superior. Whether it is the greater number of measurements made outside the dialysis unit that correlates with prognosis or whether BPs outside dialysis units are ecologically more valid is unknown. Methods and Results: A prospective cohort study was conducted in 133 patients on chronic hemodialysis. BP was measured by the patients at home for 1 week, over an interdialytic interval by ambulatory recording, and by ‘routine’ and standardized methods in the dialysis unit for 2 weeks. Up to 6 BPs were randomly selected from a 44-hour recording of ambulatory or 1-week recording of home BPs, such that the dialysis unit BPs were exactly matched to the number of ambulatory or home BPs. The relationship with left ventricular hypertrophy and all-cause mortality was analyzed using receiver-operating characteristic curves and Cox proportional hazards analysis, respectively. Over a median follow-up of 24 months, 46 patients (31%) died. A BP change of 10/5 mm Hg increased the risk of all-cause mortality by 1.22 (95% CI 1.07–1.38)/1.18 (95% CI 1.05–1.31) with the average of the 44-hour recording and 1.20 (95% CI 1.07–1.34)/1.15 (95% CI 1.03–1.27) when up to 6 random BPs from the same ambulatory recording were drawn and averaged. With home BPs the hazard ratios were 1.17/1.15 per 10/5 mm Hg increase in BP with the average of 1-week recording and 1.18/1.13 when up to 6 random BPs were drawn and averaged. Limited duration ambulatory BP monitoring of any 6-hour interval during the first 24 h or 4-day home BP recorded after the midweek dialysis was similarly predictive of all-cause mortality. Conclusions: In patients on hemodialysis, the location, not the quantity, of the BP recordings obtained outside the dialysis unit is associated with target organ damage and mortality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1159/000110090

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

Metadata

Authors
Agarwal, R., Andersen, M. J., & Light, R. P.
Venue
American Journal of Nephrology
Publisher
S. Karger AG
Published
2007-10-24
Volume
28
Issue
2
Pages
210-217
ISSN
  • 0250-8095 (ISSN-L)
  • 1421-9670
OpenAlex
W2024727968
Cited by
80
References
16
FWCI
3.24
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.