An in vitro Analysis of Metal Electrodes for Use in the Neural Environment
The DOI matches its Crossref record.
Abstract
The results of evaluation of the corrosion response of Pt, Au, Rh, Ir, Pt-10% Ir and Pt-10% Rh electrodes subjected to bipolar current pulses of 0.1 and 1.0 A/geom. cm2 in a simulated neural environment are reported. The criteria for evaluation include the extent and morphology of material removal and corrosion product formation. The chemical changes on the electrode surface and in the test electrolyte are also evaluated. Modified potentiographic methods were developed which monitor interface conditions of the electrodes during chronic, long-term biphasic current passage. Under the test conditions established by the neural model, evaluation of the corrosion response of the candidate electrode materials shows that Rh was moderately damaged at 1.0 A/geom. cm2, while the remaining test electrodes were severely damaged at this current density. While Rh, Ir and Au exhibit corrosion resistance at 0.1 A/geom. cm2, damage to all of the test materials preclude their use in any long-term chronic neural prosthetic implant under the simulated stimulation parameters of the tests. The relative corrosion resistance of the test electrode materials is related to the adherence and coherence of the corrosion product produced on the electrode surface during the first few hundred hours of stimulation. Analysis of the voltage response of the electrodes to current passage provides a means of monitoring the nucleation and growth of the corrosion product.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Electrical stimulation of neural tissue to evoke behavioral responses
Tehovnik, E. J. (1996) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00131-x · Cited by 478
A Materials Roadmap to Functional Neural Interface Design
Wellman, S. M., Eles, J. R., Ludwig, K. A., Seymour, J. P., Michelson, N. J., McFadden, W. E., Vazquez, A. L., & Kozai, T. D. Y. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701269 · Cited by 389
Brummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205
Negi, S., Bhandari, R., Rieth, L., & Solzbacher, F. (2010) · Biomedical Materials · doi:10.1088/1748-6041/5/1/015007 · Cited by 201
“Another material found to be useful is IrOx which has received considerable attention due to its ability to inject charge [13, 16, 17] and its resistance to corrosion [18].”
Background
Metadata
- Authors
- Johnson, P. F., & Hench, L. L.
- Venue
- Brain, Behavior and Evolution
- Publisher
- S. Karger AG
- Published
- 1977
- Volume
- 14
- Issue
- 1-2
- Pages
- 23-45
- ISSN
- 0006-8977 (ISSN-L)
- 1421-9743
- OpenAlex
- W2073271704
- Cited by
- 31
- References
- 0
- FWCI
- 0.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An in vitro Analysis of Metal Electrodes for Use in the Neural Environment. https://app.cochat.ai/papers/10.1159/000124612
- The paper
- Johnson, P. F., & Hench, L. L. (1977). An in vitro Analysis of Metal Electrodes for Use in the Neural Environment. Brain, Behavior and Evolution. https://doi.org/10.1159/000124612
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.