The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Inflammatory Markers in the Tears of Patients with Ocular Surface Disease
Abstract
Purpose: To determine the concentration of interleukins (IL-1β and -6) and matrix metalloproteinase 9 (pro-MMP-9) in the tears of patients with different ocular surface diseases and to examine the possible relationship between the disorders and molecular inflammation. Methods: 77 patients diagnosed as having different ocular surface disorders and 18 normal control subjects were studied. Patients were routinely examined and separated into 5 groups: (1) control, (2) blepharitis, (3) ocular allergic disease, (4) dry eye and (5) conjunctivochalasis. Ten microliters of tears were collected by a Weck cell sponge. The concentrations of IL-1β, IL-6 and pro-MMP-9 were measured by enzyme-linked immunosorbent assay, and the MMP-9 activity was evaluated with gelatin zymography. Results: Levels of IL-1β and IL-6 in tear fluid were significantly higher in conjunctivochalasis (p = 0.0062 and p = 0.0134) than in the control group. Pro-MMP-9 levels were significantly elevated in blepharitis (p = 0.013), in allergic eye disease, in dry eye and in conjunctivochalasis (all p < 0.001), in comparison to controls. Conclusions: Pro-MMP-9 levels in tears are elevated in all of the studied pathologies especially in ocular allergy and conjunctivochalasis. However, IL-1β and IL-6 were only found to be overexpressed in conjunctivochalasis. These findings illustrate the selective implication of different molecules in each disorder.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
How Matrix Metalloproteinases Regulate Cell Behavior
Sternlicht, M. D., & Werb, Z. (2001) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.17.1.463 · Cited by 3,959
Cited by
TFOS DEWS II Diagnostic Methodology report
Wolffsohn, J. S., Arita, R., Chalmers, R., Djalilian, A., Dogru, M., Dumbleton, K., Gupta, P. K., Karpecki, P., Lazreg, S., Pult, H., et al. (2017) · The Ocular Surface · doi:10.1016/j.jtos.2017.05.001 · Cited by 2,122
Dry Eye Disease: An Immune-Mediated Ocular Surface Disorder
Stevenson, W. (2012) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2011.364 · Cited by 583
Contact Lens Sensors in Ocular Diagnostics
Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400504 · Cited by 466
Chotikavanich, S., de Paiva, C. S., Li, D. Q., Chen, J. J., Bian, F., Farley, W. J., & Pflugfelder, S. C. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2476 · Cited by 402
Hagan, S., Martin, E., & Enríquez-de-Salamanca, A. (2016) · EPMA Journal · doi:10.1186/s13167-016-0065-3 · Cited by 397
Metadata
- Authors
- Acera, A., Rocha, G., Vecino, E., Lema, I., & Durán, J. A.
- Venue
- Ophthalmic Research
- Publisher
- S. Karger AG
- Published
- 2008
- Volume
- 40
- Issue
- 6
- Pages
- 315-321
- ISSN
- 0030-3747 (ISSN-L)
- 1423-0259
- OpenAlex
- W2020999562
- Cited by
- 228
- References
- 1
- FWCI
- 4.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inflammatory Markers in the Tears of Patients with Ocular Surface Disease. https://app.cochat.ai/papers/10.1159/000150445
- The paper
- Acera, A., Rocha, G., Vecino, E., Lema, I., & Durán, J. A. (2008). Inflammatory Markers in the Tears of Patients with Ocular Surface Disease. Ophthalmic Research. https://doi.org/10.1159/000150445
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.