Accuracy of Bioelectrical Impedance Analysis in Estimation of Extracellular Space in Healthy Subjects and in Fluid Retention States
The DOI matches its Crossref record.
Abstract
Bioelectrical impedance analysis (BIA) is a noninvasive method recently introduced for body fluid evaluation in healthy subjects. The purpose of this paper is to verify the reliability of bioelectrical measurements in extracellular water (ECW) prediction in healthy subjects and in fluid retention states. We studied 40 subjects (19 males and 21 females) aged 21-81 years; 22 were healthy subjects, 12 were affected by chronic heart failure, and 6 by chronic renal failure. In all subjects resistance (R) and reactance (Xc) at 1 and 50 kHz corrected for height were compared with ECW measured by the bromide dilution method. Our results suggested a different behavior of the current in fluid-retention states with respect to healthy subjects. ECW was best predicted by resistance at 1 kHz corrected for height, group (considered as dummy variable), weight and gender (R2 = 0.89, p < 0.001, SEE = 1.7 liters). The bioelectrical impedance analysis at 50 kHz explained the 89% of ECW variability when resistance and reactance corrected for height are considered with gender group and weight (R2 = 0.89, p < 0.001, SEE = 1.7 liters). In conclusion, the bioelectrical method at 1 kHz can be considered sufficiently accurate in ECW prediction in healthy subjects and in fluid retention states. Also, the bioelectrical impedance analysis at 50 kHz is useful for predicting ECW, but his role must be further investigated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Khalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712
Jaffrin, M. Y., & Morel, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.06.009 · Cited by 490
Ellis, K. J., Bell, S. J., Chertow, G. M., Chumlea, W. C., Knox, T. A., Kotler, D. P., Lukaski, H. C., & Schoeller, D. A. (1999) · Nutrition · doi:10.1016/s0899-9007(99)00147-1 · Cited by 204
Campa, F., Gobbo, L. A., Stagi, S., Cyrino, L. T., Toselli, S., Marini, E., & Coratella, G. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-021-04879-y · Cited by 115
“In contrast, the use of generalized predictive equations (Kushner and Schoeller 1986; Van Loan and Mayclin 1987; Lukaski and Bolonchuk 1988; Kushner et al. 1992; Sergi et al. 1994; Schoeller and Luke 2000; Morgenstern et al. 2002; Sun et al. 2003) led to an overall underestimation of the body fluids.”
Background
Metadata
- Authors
- Sergi, G., Bussolotto, M., Perini, P., Calliari, I., Giantin, V., Ceccon, A., Scanferla, F., Bressan, M., Moschini, G., & Enzi, G.
- Venue
- Annals of Nutrition and Metabolism
- Publisher
- S. Karger AG
- Published
- 1994
- Volume
- 38
- Issue
- 3
- Pages
- 158-165
- ISSN
- 0250-6807 (ISSN-L)
- 1421-9697
- OpenAlex
- W2018561318
- Cited by
- 76
- References
- 0
- FWCI
- 0.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of Bioelectrical Impedance Analysis in Estimation of Extracellular Space in Healthy Subjects and in Fluid Retention States. https://app.cochat.ai/papers/10.1159/000177806
- The paper
- Sergi, G., Bussolotto, M., Perini, P., Calliari, I., Giantin, V., Ceccon, A., Scanferla, F., Bressan, M., Moschini, G., & Enzi, G. (1994). Accuracy of Bioelectrical Impedance Analysis in Estimation of Extracellular Space in Healthy Subjects and in Fluid Retention States. Annals of Nutrition and Metabolism. https://doi.org/10.1159/000177806
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.